研究目的
To develop a sandwich structural QDs-SiO2-BN nanoplate assembly material (QDs-SiO2-BNAs) to reduce the thermal quenching and enhance the stability of QDs in LEDs.
研究成果
The QDs-SiO2-BNAs structure not only improves the stability of the QDs but also benefits the luminous efficacy of the QD-converted LEDs, demonstrating significant potential for LED lighting and display applications.
研究不足
The study does not address the scalability of the synthesis process for industrial applications or the long-term stability beyond the tested 250 hours under sustained driving.
1:Experimental Design and Method Selection:
The study involves the synthesis of QDs-SiO2-BNAs by embedding QDs-SiO2 into the interlayer of layer-by-layer assembled BN nanoplates, with BN nanoplates pretreated by SiO2 encapsulation to strengthen the interaction with QDs-SiO
2:Sample Selection and Data Sources:
CdSe/ZnS QDs were synthesized and encapsulated with silica. BN nanoplates were surface treated with silica.
3:List of Experimental Equipment and Materials:
Materials include selenium powder, cadmium stearate, zinc acetate, 1-octadecene, sulfur, trioctylphosphine, stearic acid, tetramethoxysilane, cyclohexane, n-hexane, IGEPAL CO-520, BN platelets, ethanol, dimethylbenzene, and silicone resin. Equipment includes TEM, SEM, EDS, FTIR-spectrometer, QY test system, infrared thermal images recorder, and LED automatic temperature control photoelectric analysis and measurement system.
4:Experimental Procedures and Operational Workflow:
The procedure involves the preparation of CdSe/ZnS QDs, QDs-SiO2, BN-SiO2, QDs-SiO2-BNAs, and QDs/BN, followed by characterization and fabrication of QD-LEDs.
5:Data Analysis Methods:
The study uses photoluminescence spectroscopy, TEM, SEM, EDS, FTIR, quantum efficiency measurements, infrared thermal imaging, and luminous efficiency measurements.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
FEI Tecnai G2 Spirit TWIN transmission electron microscope
G2 Spirit TWIN
FEI
Transmission electron spectroscopy (TEM) was performed on this microscope operating at 100 kV.
-
FEI Nova NanoSEM 450
Nova NanoSEM 450
FEI
Scan electron microscopy (SEM) experiments were performed on this microscope.
-
OceanOptics QEpro QY test system
QEpro QY
OceanOptics
The quantum efficiency (QE) measurements were carried out on this test system under 390 nm blue laser irradiation.
-
Optris PI200
PI200
Optris
The infrared thermal images were recorded on this device.
-
EDAX Octane Plus Det
Octane Plus Det
EDAX
EDS (energy-dispersive spectrometer) characterization was performed on this detector operating at 1.76 keV.
-
Thermo-Nicolet iS50 FTIR-spectrometer
iS50
Thermo-Nicolet
Fourier transform infrared spectroscopy (FTIR) measurements were carried out on this spectrometer.
-
EVERFINE ATA-1000 LED automatic temperature control photoelectric analysis and measurement system
ATA-1000
EVERFINE
The luminous efficiency and optical power were recorded on this system.
-