研究目的
To analyze the failure of metallic armoured electro-optic mechanical cables in underwater towed sonar systems and improve their design.
研究成果
The study successfully identified the causes of cable failure and led to the development of an improved indigenous cable with enhanced radial load bearing capacity, ready for sea trials.
研究不足
The study was limited to specific conditions simulating deployment and retrieval scenarios, and may not account for all operational stresses.
1:Experimental Design and Method Selection:
Cyclic load testing was conducted to simulate deployment-retrieval conditions of towed array sonar systems.
2:Sample Selection and Data Sources:
Both indigenously developed and imported cable samples were tested.
3:List of Experimental Equipment and Materials:
Flexural testing machine with 65 mm and 290 mm diameter rollers.
4:Experimental Procedures and Operational Workflow:
Cables were subjected to 100 cycles of deployment-retrieval tests under varying loads.
5:Data Analysis Methods:
Diameter measurements and electrical/optical continuity checks were performed before and after tests.