研究目的
To investigate the variation of optical properties of nitrogen-doped graphene quantum dots with short/mid/long-wave ultraviolet for the development of the UV photodetector.
研究成果
The study demonstrates that the optical and structural properties of NGQDs can be controllably altered via different wavelength UV-treatment, leading to the development of highly sensitive and reproducible UV photodetectors with high responsivity and detectivity.
研究不足
The study focuses on the optical and structural changes of NGQDs under UV irradiation and their application in UV photodetectors. Potential limitations include the scalability of the synthesis method and the stability of the photodetector devices under prolonged UV exposure.
1:Experimental Design and Method Selection:
NGQDs were synthesized from a single glucosamine precursor via a hydrothermal method and treated with UV light at three different wavelengths (254, 302, 365 nm) for time intervals of 0 to 60 min.
2:Sample Selection and Data Sources:
Aqueous suspension of glucosamine-HCl was used as the precursor.
3:List of Experimental Equipment and Materials:
High-resolution Transmission Electron Microscope (TEM JEOL JEM-2100), Horiba Scientific SPEX NanoLog Spectrofluorimeter, Cary 60 UV-Vis absorption spectrometer, Thermo Nicolet Nexus 670 FTIR, DeltaNu Raman spectrometer, NT-MDT nanosolver AFM, Anatech Hummer-VII gold sputtering deposition system, Keithley 2420 Source Meter.
4:Experimental Procedures and Operational Workflow:
NGQDs were synthesized, purified, and then irradiated with UV light. Optical and structural properties were characterized before and after UV treatment. UV photodetector devices were fabricated and their performance was evaluated.
5:Data Analysis Methods:
Absorbance and fluorescence spectra were analyzed to assess changes in optical properties. TEM and AFM were used to evaluate changes in size and morphology. FTIR and Raman spectroscopy were used to analyze chemical composition and structural changes.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Transmission Electron Microscope
JEOL JEM-2100
JEOL
Morphological characterization of NGQDs
暂无现货
预约到货通知
-
UV-Vis absorption spectrometer
Cary 60
Agilent Technologies
Measurement of absorbance spectra
Cary 60 UV-Vis Spectrophotometer
立即获取同款设备
-
FTIR spectrometer
Nicolet Nexus 670
Thermo
Detection of vibrational transitions
暂无现货
预约到货通知
-
Source Meter
Keithley 2420
Keithley
Assessment of electrical response
暂无现货
预约到货通知
-
Spectrofluorimeter
SPEX NanoLog
Horiba Scientific
Measurement of visible/NIR fluorescence spectra
暂无现货
预约到货通知
-
Raman spectrometer
DeltaNu
DeltaNu
Characterization of graphitic structure
暂无现货
预约到货通知
-
Atomic Force Microscope
NT-MDT nanosolver
NT-MDT
Assessment of height profiles
暂无现货
预约到货通知
-
Gold sputtering deposition system
Anatech Hummer-VII
Anatech
Deposition of gold electrodes
暂无现货
预约到货通知
-
登录查看剩余6件设备及参数对照表