研究目的
Investigating the generation of ZnS, CdS, CaS, and MgS quantum dots in the matrix of distarch phosphate, an anionic polysaccharide, and analyzing their interactions with the matrix.
研究成果
Distarch phosphate is suitable for the generation of CdS QDs, with the anionic character of the matrix providing larger and less aggregated QDs than non-ionic polysaccharide matrices. The study highlights the influence of the polysaccharide matrix on QD formation and properties.
研究不足
The study found that only CdS formed uniform QDs in the distarch phosphate matrix, with other QDs showing less uniformity and stability. The hydrolysis of MgS and CaS salts affected the matrix integrity.
1:Experimental Design and Method Selection
The study involved the generation of quantum dots (QDs) in a distarch phosphate matrix, analyzing their interactions with the matrix through FTIR spectra, thermograms, and Differential Scanning Calorimetry.
2:Sample Selection and Data Sources
Distarch phosphate was purchased from WPZZ.SA (Luboń, Poland). ZnS, CdS, CaS, and MgS nanocomposites were prepared from gelatinized distarch phosphate and respective salts.
3:List of Experimental Equipment and Materials
High resolution JEOL 7550 scanning electron microscope, F7000 Hitachi spectrophotometer, Mattson 3000 FT-IR spectrophotometer, Mettler-Toledo 851e apparatus, Mettler-Toledo 821e calorimeter, Shimadzu 10AC pump, Dawn-DSP-F multiangle laser light scattering detector, L-7490 differential refractive index detector.
4:Experimental Procedures and Operational Workflow
Distarch phosphate was gelatinized, treated with salts to prepare nanocomposites, and then analyzed for QD generation and properties.
5:Data Analysis Methods
Analysis included TEM for size and morphology, photoluminescence spectrometry for emission properties, FTIR-ATR spectrometry for interactions, thermogravimetry for decomposition, DSC for thermal effects, and HPSEC-MALLS-RI for molecular weight and radii of gyration.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
JEOL 7550 scanning electron microscope
7550
JEOL
Analysis of sizes and morphologies of nanoparticles
-
F7000 Hitachi spectrophotometer
F7000
Hitachi
Photoluminescence measurements
-
Shimadzu 10AC pump
10AC
Shimadzu
Part of the HPSEC system for molecular weight determination
-
Mattson 3000 FT-IR spectrophotometer
3000
Mattson
Recording FTIR-ATR spectra
-
Mettler-Toledo 851e apparatus
851e
Mettler-Toledo
Thermogravimetric analysis coupled with mass spectrometry
-
Mettler-Toledo 821e calorimeter
821e
Mettler-Toledo
Differential scanning calorimetry
-
Dawn-DSP-F multiangle laser light scattering detector
Dawn-DSP-F
Wyatt Technology
Detection in HPSEC system
-
L-7490 differential refractive index detector
L-7490
Merck
Detection in HPSEC system
-