研究目的
Investigation of electrically driven perovskite light-emitting diodes (PeLEDs) with hybrid organic additives and colloidal NiOx nanoparticle hole transport layer for improved performance.
研究成果
The novel PeLED with a multiple-additive-assisted CsPbBr3 EML and a colloidal NiOx NP HTL demonstrated significant improvements in performance, including a low turn-on voltage of 2.4 V, high luminance maximum of 4456 cd/m2, and enhanced current efficiency of 2.9 cd/A. These improvements were attributed to better hole transporting and high radiative recombination rate.
研究不足
The study does not address the long-term stability of PeLEDs under operational conditions. The impact of environmental factors on device performance was not explored.
1:Experimental Design and Method Selection:
The study involved the synthesis of NiOx nanoparticles and CsPbBr3 perovskite powder, followed by the fabrication of PeLEDs with various organic additives in the emission layer.
2:Sample Selection and Data Sources:
CsPbBr3 powder was synthesized from PbBr2 and CsBr in DMSO, and NiOx NPs were prepared from nickel nitrate hexahydrate.
3:List of Experimental Equipment and Materials:
Instruments included a Rigaku MiniFlex II X-ray diffractometer, UV-VIS spectrometer, TEM, AFM, and UPS. Materials included CsPbBr3, NiOx NPs, PEO, TPBi, and FIrpic.
4:Experimental Procedures and Operational Workflow:
The PeLEDs were fabricated by spin-coating NiOx NP and CsPbBr3 layers on ITO-glass substrates, followed by deposition of TPBi and Ca/Al electrodes.
5:Data Analysis Methods:
The performance of PeLEDs was evaluated through luminance–current density–voltage measurements and EL spectra analysis.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Atomic force microscope
Innova
Bruker
Obtaining surface morphology of films
暂无现货
预约到货通知
-
Keithley 2400 source meter
2400
Keithley
Measuring current–voltage curves
暂无现货
预约到货通知
-
Rigaku MiniFlex II X-ray diffractometer
MiniFlex II
Rigaku
Obtaining X-ray diffraction patterns
-
Fiber-optic spectrometer
USB 4000
Ocean Optics
Measuring electroluminescence spectra
暂无现货
预约到货通知
-
Transmission electron microscope
JEM-2100F
JEOL
Obtaining size of nanoparticles
暂无现货
预约到货通知
-
UV-VIS spectrometer
LKU-5200
LINKO
Measuring absorption spectra
暂无现货
预约到货通知
-
Electron spectrometer
ULVAC-PHI
Chigasaki
Obtaining UPS spectra
暂无现货
预约到货通知
-
Luminance meter
LS-110
Minolta
Measuring luminance properties
暂无现货
预约到货通知
-
登录查看剩余6件设备及参数对照表