研究目的
To evaluate and compare radiographic crestal bone loss (CBL) and soft tissue parameters around submerged/two-stage and nonsubmerged/one-stage single implants with the same endosseous portion and identical intramucosal laser-microgrooved surface, after 3 years of loading.
研究成果
After 3 years of loading, no differences were found in CBL and soft tissue conditions between single submerged two-stage and non-submerged one-stage laser-microgrooved implants.
研究不足
The study's limitations include the use of two different abutments, a small sample size, and lack of histological data.
1:Experimental Design and Method Selection:
A randomized clinical trial with a split-mouth design was conducted to compare submerged/two-stage and nonsubmerged/one-stage single implants.
2:Sample Selection and Data Sources:
Twenty partially edentulous patients were enrolled, with each receiving one submerged and one nonsubmerged implant in posterior areas.
3:List of Experimental Equipment and Materials:
Tapered Internal Laser-Lok? implant and Tapered Tissue Level Laser-Lok? implant were used.
4:Experimental Procedures and Operational Workflow:
Implants were placed, and radiographic and clinical examinations were performed at implant placement, prosthetic restoration delivery, and yearly follow-ups.
5:Data Analysis Methods:
Statistical analysis was performed using SPSS software, including ANOVA and Wilcoxon signed-rank tests.