To develop shape-deformable and self-healing electroluminescence displays (SSELDs) that can self-repair mechanical damages and recover their initial electronic performance.
研究成果
The study demonstrated a simple and robust route for fabricating shape-deformable and self-healing displays using a viscoelastic light-emitting composite. The SSELDs showed excellent self-healing capabilities and shape deformability, making them suitable for practical applications in lighting and sensors.
研究不足
The manual shutdown process was necessary for 'self-healing of the device,' which could be resolved by combining a sensor system that detects hole formation.
1:Experimental Design and Method Selection:
The study involves fabricating a polymer composite of elastomeric poly(urethane) (PU) and light-emitting Cu-doped ZnS microparticles with the addition of Triton X-100 (TX) to render the composite viscoelastic.
2:Sample Selection and Data Sources:
The materials used include aqueous aliphatic PU dispersion, green, orange, and blue ZnS microparticles, stainless steel wire, and a nonionic surfactant Triton X-
3:List of Experimental Equipment and Materials:
1 Equipment includes Rigaku SmartLab HR-XRD, Spectrum 100 FT-IR, Olympus BX 51M optical microscope, NETZSCH DSC 124 Polyma, TA Instrument Q100, Mettler Toledo AG-TGA/SDTA851e, TA Instrument Q800 DMA, Konica CS 2000 spectroradiometer, Agilent 33220A function generator, TREK 623B high-voltage amplifier, and ZIMMER Electronics Systems LMG
4:Experimental Procedures and Operational Workflow:
5 The VLC was prepared by mixing the PU dispersion/TX mixture with ZnS microparticles, followed by annealing. SSELDs were fabricated by inserting VLCs between top and bottom ITO electrodes.
5:Data Analysis Methods:
The study involved XRD, FT-IR, optical microscopy, DSC, TGA, DMA, and spectroradiometry for characterization.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Rigaku SmartLab HR-XRD
Rigaku
Collecting powder XRD patterns
-
Spectrum 100 FT-IR
PerkinElmer
Acquiring FT-IR spectra
-
Olympus BX 51M
Olympus
Visualizing the VLCs
-
NETZSCH DSC 124 Polyma
NETZSCH
Carrying out DSC
-
TA Instrument Q100
TA Instrument
Performing TGA
-
Mettler Toledo AG-TGA/SDTA851e
Mettler Toledo
Performing TGA
-
TA Instrument Q800
TA Instrument
Carrying out DMA
-
Konica CS 2000
Konica
Obtaining luminance and EL spectra
-
Agilent 33220A
Agilent
Function generator for operating the device
-
TREK 623B
TREK
High-voltage amplifier for operating the device
-
ZIMMER Electronics Systems LMG 500
ZIMMER Electronics Systems
Recording current–voltage–luminance characteristics
-
登录查看剩余9件设备及参数对照表