研究目的
Investigating the metrological analysis of optoelectronic monitoring systems for pro? lograms of shells of rotation to determine the feasibility of applying one or another system based on required accuracy and speed.
研究成果
The spectral method and the geometrical center of gravity method are advisable for technical implementation of optoelectronic systems due to minimal methodological errors. The selection of an optical setup should consider the manufacturing process, technical characteristics, and industrial automation level.
研究不足
The study assumes deviations from the nominal radius do not exceed the tolerance for the size of the part and the amplitude of the ?rst harmonic component de? ning eccentricity is equal to zero. The applicability of methods may vary based on the spectral structure of the pro? lograms.