研究目的
To synthesize new water-soluble cationic gallium(III) and zinc(II) phthalocyanines and investigate their photodynamic activities and cytotoxicity for potential use in Photodynamic therapy (PDT).
研究成果
The cationic Zn(II) phthalocyanine complex exhibits high photocytotoxicity upon light exposure, making it a promising photosensitizer for PDT. The Ga(III)Cl complex shows no photocytotoxicity but has high solubility and no aggregation in aqueous media.
研究不足
The study is limited to in vitro evaluation using HEp2 cells. The photodynamic therapy (PDT) efficacy in vivo and potential side effects were not investigated.
1:Experimental Design and Method Selection:
The synthesis involved macrocyclization and quaternization reactions to produce cationic Ga(III) and Zn(II) phthalocyanines. Spectroscopic properties, singlet oxygen generation, and cytotoxicity were investigated.
2:Sample Selection and Data Sources:
Human HEp2 cells were used for cytotoxicity and intracellular localization studies. Spectroscopic data were obtained using UV-Vis and fluorescence spectroscopy.
3:List of Experimental Equipment and Materials:
Instruments included a Shimadzu UV-3100 spectrometer, Shimadzu RF-5300PC spectrofluorometer, JEOL delta ECX-500 spectrometer, Bruker microTOF, and bioMérieux VITEK? MS for mass spectrometry.
4:Experimental Procedures and Operational Workflow:
The synthesis steps included macrocyclization and quaternization reactions. Cytotoxicity was evaluated using CellTiter Blue assay, and intracellular localization was determined using fluorescence microscopy with organelle-specific probes.
5:Data Analysis Methods:
Data were analyzed using UV-Vis and fluorescence spectroscopy, ESR for singlet oxygen detection, and statistical analysis for cytotoxicity assays.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Shimadzu UV-3100 spectrometer
UV-3100
Shimadzu
Recording UV-Vis absorption spectra
暂无现货
预约到货通知
-
Shimadzu RF-5300PC spectrofluorometer
RF-5300PC
Shimadzu
Recording photoluminescence (PL) spectra
暂无现货
预约到货通知
-
JEOL delta ECX-500 spectrometer
delta ECX-500
JEOL
Recording 1H NMR spectra
暂无现货
预约到货通知
-
Bruker microTOF
microTOF
Bruker
Recording electrospray ionization mass (ESI-TOF-MS) spectra
暂无现货
预约到货通知
-
Absolute PL quantum yield measurement apparatus
C9920-02
Hamamatsu Photonics
Evaluating fluorescence quantum yields
暂无现货
预约到货通知
-
Xenon lamp
MAX-301
Asahi Spectra
Light source to induce photosensitized singlet oxygen evolution reaction
暂无现货
预约到货通知
-
Optical power meter
8230E
ADCMT
Measuring light intensities
-
Optical sensor
82311B
ADCMT
Measuring light intensities
暂无现货
预约到货通知
-
Bruker EMX Plus spectrometer
EMX Plus
Bruker
Recording EPR spectra
暂无现货
预约到货通知
-
bioMérieux VITEK? MS
VITEK? MS
bioMérieux
Recording matrix-assisted laser desorption/ionization time-of-flight mass (MALDI-TOF-MS) spectra
暂无现货
预约到货通知
-
登录查看剩余8件设备及参数对照表
查看全部