Investigating the electromagnetic coupling of the Advanced Virgo input mirror payload in response to a slowly time-varying magnetic field and its impact on the low frequency sensitivity of the gravitational-wave detector.
研究成果
The FE model validated through experimental measurements shows that the magnetic noise contribution to the Advanced Virgo strain noise is currently negligible but may become significant as the detector approaches its design sensitivity. Further measurements and refinements are needed to fully understand and mitigate this potential noise source.
研究不足
The study is limited by the complexity of the payload's assembly and the assumptions made in the FE model, such as neglecting steel and titanium parts due to their lower conductivity. The environmental magnetic field's uniformity assumption may not hold in real conditions.
1:Experimental Design and Method Selection:
The study employs finite element (FE) analysis to model the electromagnetic coupling of the Advanced Virgo input mirror payload. The FE model is validated through experimental measurements.
2:Sample Selection and Data Sources:
The payload is the main sample, with measurements taken in a controlled environment to validate the FE model.
3:List of Experimental Equipment and Materials:
Includes a triaxial magnetic field sensor FL3-100, AC current generator (CoCo80), linear amplifier (BAA 120), and a structural PVC cubic frame with two coils.
4:Experimental Procedures and Operational Workflow:
The payload's response to a slowly time-varying magnetic field is measured and compared with FE simulations to validate the model.
5:Data Analysis Methods:
The agreement between measurements and simulations is assessed using a relative difference function, and the magnetic noise contribution to the strain noise is computed.