研究目的
Investigating the local chemical environment in hexane-methylethylketone solutions as a model of polyethylene degradation using fluorescence spectroscopy.
研究成果
The fluorescence spectra of pyrene and Prodan in hexane-MEK solutions showed clear dependence on the solvent environment, making fluorescence intensity ratios useful indicators of solution polarity. The fluorescence probe method, especially using Prodan, was found to be markedly more sensitive than the conventional carbonyl index by IR spectroscopy for detecting early stages of polymer degradation. This method is expected to assist in the development of material degradation analysis techniques.
研究不足
The study notes that it would be difficult to evaluate the absolute concentration of carbonyl groups from the fluorescence index due to the presence of other moieties like hydroxyl and carboxyl groups in actual polymer degradation. Additionally, fluorescence indexes reflect information corresponding to the regions where the probe molecule is present, which may not represent the entire polymer environment.
1:Experimental Design and Method Selection:
The study used fluorescence spectroscopy to investigate the local chemical environment in hexane-methylethylketone solutions, modeling polyethylene degradation. Pyrene and Prodan were used as fluorescence probes due to their sensitivity to solvent polarity.
2:Sample Selection and Data Sources:
Hexane-methylethylketone mixtures were prepared with varying ratios to model different stages of polyethylene degradation. Pyrene and Prodan were dissolved in these mixtures at specific concentrations.
3:List of Experimental Equipment and Materials:
A Hitachi F-7000 spectrofluorometer was used for fluorescence measurements, and a Shimadzu IRAffinity-1 spectrometer connected to a diamond attenuated total reflectance (ATR) unit was used for IR spectra measurements.
4:Experimental Procedures and Operational Workflow:
Fluorescence spectra were measured in a quartz cell with an optical path length of 1 cm. Excitation and emission slits with a bandpass of 2.5 nm were used. IR spectra were measured by directly loading samples on the ATR crystal.
5:5 nm were used. IR spectra were measured by directly loading samples on the ATR crystal.
Data Analysis Methods:
5. Data Analysis Methods: The fluorescence intensity ratios (I384/I373 for pyrene and I380/I420 for Prodan) were analyzed to investigate the local chemical environment. The carbonyl index (CI) from IR measurements was compared with fluorescence indexes.