研究目的
Investigating the fabrication of flexible silver nanowire transparent conductive films through an electrostatic adsorption self-assembly process.
研究成果
The electrostatic adsorption self-assembly process is a facile and effective method for fabricating flexible AgNW transparent conductive films with excellent optoelectrical properties, low surface roughness, and high reliability. The method is suitable for arbitrary shaped substrates, broadening its application in optoelectronic devices.
研究不足
The method requires precise control over the concentration of AgNW dispersion and the amount of dispersant to achieve optimal optoelectrical performance. Over-long ion bombardment time can damage the AgNW network.
1:Experimental Design and Method Selection:
The study employed an electrostatic adsorption self-assembly process to fabricate AgNW networks on flexible PET substrates.
2:Sample Selection and Data Sources:
Modified PET films with positively charged functional groups and AgNW dispersions with anionic dispersant were used.
3:List of Experimental Equipment and Materials:
Polyvinylpyrrolidone (PVP), 1,2-propylene glycol (PG), tetrabutylammonium chloride (TBAC), catechol, silver nitrate (AgNO3), Zonyl FSP, N, N0-(dimethylamino) ethyl methacrylate (DMAEMA), 1-bromododecane (R12Br), meta-sodium periodate (NaIO4), precision ion etching system (RES 101, Leica, Germany).
4:Experimental Procedures and Operational Workflow:
The process involved graft polymerization onto PET films, immersion into AgNW dispersion, and ion bombardment treatment to remove insulating dispersant.
5:Data Analysis Methods:
X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), zeta potential measurements, scanning electron microscopy (SEM), atomic force microscopy (AFM), UV-NIR spectrophotometry, and 4-point probes resistivity measurement.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
precision ion etching system
RES 101
Leica
Used to remove non-conductive polymers from the surface of AgNW films.
-
X-ray photoelectron spectrometer
ESCALAB 250
Thermofisher VG
Used to detect the graft polymerization of DMAEMA-R12Br onto PET films.
-
Fourier transform infrared spectroscopy
NICOLET 6700
Thermo Scientific
Used to characterize the pristine AgNWs and redispersed AgNWs.
-
ZS Zetasizer apparatus
Malvern Zetasizer Nano-ZS90
Malvern
Used to measure zeta potentials.
-
solid surface zeta potential analyzer
SURPASS
Antor Paar
Used to measure zeta potentials.
-
scanning electron microscopy
SUPRA 55 Sapphire
Zeiss
Used to characterize the morphologies of TCFs.
-
atomic force microscopy
INNOVA
Bruker
Used to observe the surface roughness of TCFs.
-
UV-NIR spectrophotometer
CARY 5000
Agilent
Used to measure the optical transmittance of TCFs.
-
4-point probes resistivity measurement system
RTS-9
Used to measure the sheet resistance of TCFs.
-
登录查看剩余7件设备及参数对照表
查看全部