研究目的
To develop an ultra-sensitive H2S gas sensor based on WO3 nanocubes with low operating temperature to reduce power consumption and improve detection capabilities for harmful gases.
研究成果
The nanocube WO3 sensor demonstrates high sensitivity, excellent selectivity, and fast response to H2S at a low operating temperature of 100°C, making it suitable for practical applications in gas detection with reduced power consumption.
研究不足
The study does not address long-term stability under varying environmental conditions, potential interference from other gases in real-world applications, and scalability of the synthesis method for mass production.
1:Experimental Design and Method Selection:
The study used a hydrothermal method to synthesize WO3 nanocubes without templates or organic additives, followed by sensor fabrication and characterization to evaluate gas sensing properties.
2:Sample Selection and Data Sources:
Analytical grade chemicals from Sinopharm Chemical Reagent Co. Ltd. were used; samples were synthesized and characterized for structural and morphological analysis.
3:List of Experimental Equipment and Materials:
Equipment includes D8 ADVANCE diffractometer (XRD), Hitachi S-4800 FE-SEM, WS-30A static testing system, agate mortar, alumina tube, gold electrodes, Ni-Cr alloy coil, and various chemicals like Na2WO4·2H2O and HCl.
4:Experimental Procedures and Operational Workflow:
Steps involved dissolving Na2WO4·2H2O, adding HCl, hydrothermal reaction at 180°C, centrifugation, drying, paste preparation, coating on alumina tube, annealing, aging, and gas sensing tests with resistance measurements.
5:Data Analysis Methods:
XRD patterns compared with JCPDS files, SEM for morphology, sensor response calculated as Ra/Rg for reducing gases, response and recovery times defined as 90% resistance change time.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
D8 ADVANCE diffractometer
D8 ADVANCE
Bruker
Used for X-ray diffraction analysis to determine the crystal phase of the synthesized WO3 powder.
-
field emission scanning electron microscope
S-4800
Hitachi
Used to observe the morphology of the WO3 powder.
-
static testing system
WS-30A
Winsen Technology Co. Ltd.
Used to investigate the electrical resistance of the sensor during gas sensing measurements.
-
agate mortar
Used to mix the WO3 powder with deionized water to form a viscous paste for sensor fabrication.
-
alumina tube
Used as the substrate for coating the WO3 paste to form the sensor film.
-
gold electrodes
Installed on the alumina tube to form electrical contacts for the sensor.
-
Ni-Cr alloy coil
Used as a heater inserted into the alumina tube to provide operating temperature during testing.
-