Optimal Design of Sandwich Composite Cradle for Computed Tomography Instrument by Analyzing the Structural Performance and X-ray Transmission Rate
摘要: Carbon fiber-reinforced composite has an excellent X-ray transmission rate as well as specific modulus and strength. The major components of medical devices, X-ray systems, and computed tomography (CT) equipment that require superior X-ray transmission performance also require structural performance for deformation. Therefore, medical components consist of a sandwich composite structure with carbon fiber composites applied as a face material. The X-ray transmission ratios of face material and foam material were measured according to thickness, and the relation equation for thickness and X-ray transmission rate was derived. The X-ray transmission rate for the sandwich composite structure consisting of face and core material was measured and the relationship between the X-ray transmission rate and the dimension for thickness of sandwich cradle was derived. Using the optimization process, the thicknesses of face and core materials for sandwich cradles were determined to minimize the cost of used materials. They also met the criteria that the deflection should not be more than 20 mm, and the X-ray transmission rate of the cradle should be equal to or greater than that of aluminum at 1.5 mm thickness. The sequence pattern of face material was proposed through structural analysis. The face material of the sandwich cradle was manufactured by a resin infusion and vacuum bagging method, followed by inserting the core between the cured faces. Next, the sandwich cradle assembly was completed and re-cured. The sandwich cradle met the criteria that the deflection at the end was 19.04 mm and the X-ray transmission was 78.7% greater than the X-ray transmission of 1.5 mm aluminum.
关键词: X-ray transmission,computed tomography,sandwich composite,CT cradle
更新于2025-09-19 17:15:36
-
Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance
摘要: Objective Evaluate and compare the image quality and acceptance of a full MBIR algorithm to that of an earlier full IR hybrid algorithm and filtered back projection (FBP). Methods Acquisitions were performed with a 320 detector-row CT scanner with seven different dose levels. Images were reconstructed with three algorithms: FBP, full hybrid iterative reconstruction (HIR), and a full model-based iterative reconstruction algorithm (full MBIR). The sensitometry, spatial resolution, image texture, and low-contrast detectability of these algorithms were compared. Subjective analysis of low-contrast detectability was performed. Ten radiologists answered a questionnaire on image quality and confidence in full MBIR images in clinical practice. Results The contrast-to-noise ratio of full MBIR was significantly higher than in the other algorithms (p < 0.0015). The spatial resolution was also higher with full MBIR at high frequencies (> 0.3 lp/mm). Full MBIR at low dose levels led to better low-contrast detectability and more inserts being identified with a higher confidence (p < 0.0001). Full MBIR was associated with a change in image texture compared to HIR and FBP. Eighty percent of radiologists judged general appearance and texture of full MBIR images worse than HIR. Moreover, compared with HIR, for 50% of radiologists, the diagnostic confidence on full MBIR images was worse. Questionnaire reliability was considered acceptable (Cronbach alpha 0.7). Conclusion Compared to conventional iterative reconstruction algorithms, full MBMIR presented a higher image quality and low-contrast detectability and a worse acceptance among radiologists.
关键词: Computed tomography,Phantom imaging,Image quality,Abdomen,Image reconstruction
更新于2025-09-19 17:15:36
-
Integrate imaging approach for minimally invasive and robotic procedures
摘要: Over the past two decades, robotic and minimally invasive cardiac surgery has been continuously refined and is currently an alternative to traditional open-heart surgery for some patients. The parallel evolution of imaging modalities has made robotic surgery safer and more efficient. Here, we review the pre- and post-operative use of computed tomography (CT) in minimally invasive and robotic cardiac procedures.
关键词: Cardiac surgical procedures,vascular graft occlusion,X-ray computed tomography,mitral valve annuloplasty,minimally invasive surgical procedures
更新于2025-09-19 17:15:36
-
Pore space characteristics and corresponding effect on tensile properties of Inconel 625 fabricated via laser powder bed fusion
摘要: In this work, the tensile behavior of Inconel 625 parts fabricated via laser powder bed fusion (LPBF) at different laser power levels is examined, and correlated to bulk porosity as well as pore characteristics such as pore size, aspect ratio morphology, and polar orientation extracted from X-ray computed tomography (CT). Scanning electron microscopy (SEM) is employed to identify the fracture mode and origin of failure in the pulled samples. Microstructural examination on the as-built samples showed that increasing the laser power resulted in the transition of melting mode, from lack of fusion to keyhole, with an increase in part bulk density from 98.86% to 99.29%, respectively. It was found that the general bulk porosity level does not correlate directly with the Ultimate Tensile Strength (ranging between 780–820 MPa) and strain to fracture (ranging between 0.2–0.39) behavior of the parts. Detailed pore space characteristics obtained from CT datasets before and after the tensile test contributed to establishing a relationship between defects size, morphology, orientation and tensile properties of the samples. In general, it was found that strain to failure is directly influenced by pore space characteristics, while tensile strength is influenced by a combination of pore space and microstructural characteristics. This study also identified that there are systematic bias effects in the LPBF process, likely introduced by the combination of nuisance variables such as powder layer spreading and gas flow.
关键词: Inconel 625 alloy,Pore space characteristics,Laser powder bed fusion,Tensile behavior,X-ray computed tomography
更新于2025-09-19 17:13:59
-
Positron emission tomography/computed tomography dual imaging using 18-fluorine flurodeoxyglucose and 11C-labeled 2-?2-carbomethoxy-3-?2-(4-fluorophenyl) tropane for the severity assessment of Parkinson disease
摘要: The value of dual imaging mode for the severity assessment of Parkinson disease (PD) is explored by conducting positron emission tomography computed tomography (PET/CT) double imaging using combined 18-fluorine flurodeoxyglucose (18F-FDG) brain metabolism and 11C-2b-carbomethoxy-3b-(4-fluorophenyl) tropane (11C-CFT) brain dopamine transporter (DAT). A total of 102 patients with PD and 50 healthy people in the control group are enrolled for the PET/CT dual imaging of 18F-FDG brain metabolism and 11C-CFT brain DAT. The characteristics of 18F-FDG PET/CT and 11C-CFT PET/CT imaging are analyzed by delineating the region of interest. Differences in the glucose metabolism and DAT distribution in the basal ganglia of patients with PD and healthy control group in the PET/CT imaging and the radioactive distribution characteristics of cerebral cortex in glucose metabolism imaging are compared. The characteristics of PET/CT imaging of 11C-CFT brain DAT in the ganglion region in absorbing 11C-CFT in different PD groups are analyzed. Compared with the healthy control group, changes in the cerebral glucose metabolism in the PD group mainly occur due to the increased symmetry metabolism of the nucleus of bilateral basal ganglia and the decreased metabolism of the cerebral cortex as shown in the 18F-FDG PET/CT images. With disease progression, the bilateral parietal, frontal, temporal, and occipital leaves showed different degrees of FDG metabolism. Statistically significant difference is observed for the11C-CFT absorption among the caudate nucleus and the anterior, middle, and posterior nuclei of the bilateral basal ganglia of the PD and healthy control groups. In the PD group, the bilateral caudate nucleus and the anterior, middle, and posterior parts of the putamen show decreased DAT distribution. Regardless of unilateral or bilateral symptoms, the DAT distribution in the nucleus of the contralateral basal ganglia and in the posterior part of the nucleus is substantially reduced. PET/CT dual imaging by 18F-FDG PET/CT combined with 11C-CFT PET/CT features high application value for the severity assessment of PD.
关键词: brain metabolism,dopamine transporter,computed tomography of electron emission,Parkinson disease
更新于2025-09-19 17:13:59
-
[IEEE 2019 5th International Conference on Signal Processing, Computing and Control (ISPCC) - Solan, India (2019.10.10-2019.10.12)] 2019 5th International Conference on Signal Processing, Computing and Control (ISPCC) - Technical Survey and review on MPPT techniques to attain Maximum Power of Photovoltaic system
摘要: The lp (0 < p < 1) regularization has attracted a great attention in the compressive sensing field, because it can obtain sparser solutions than the well-known l1 regularization. Recently, we developed an approximate general analytic thresholding representation for any lp regularization with 0 < p < 1. The derived thresholding representations are exact for the well-known soft-threshold filtering for l1 regularization and the hard-threshold filtering for l0 regularization. Because the lp regularization is a nonconvex problem, an iterative algorithm can only converge to local optima instead of the global optimum. In this paper, we propose an alternating iteration algorithm for computed tomography reconstruction in a thresholding form based on our general analytic thresholding representation for better convergent properties. The alternating iteration algorithm alternatively minimizes one l1 and one lp (0 < p < 1) regularized objective functions. While the lp regularization can help to find a sparser solution, the l1 regularization can help to monitor the solution not away from the global optimum. Both numerical simulations and phantom experiments are performed to evaluate the proposed alternating iteration algorithm. Compared with the lp (0 < p < 1) regularization using a single p, the proposed alternating iteration algorithm reduces more data measurements for accurate reconstruction and is more robust for projection noise.
关键词: Compressive sensing,lp regularization,least square solution,image reconstruction,alternating iteration,computed tomography
更新于2025-09-19 17:13:59
-
[IEEE 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Chicago, IL, USA (2019.6.16-2019.6.21)] 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Marked improvement of the photoresponsivity of BaSi <sub/>2</sub> light absorbers by increasing growth temperature and three-step growth method
摘要: The lp (0 < p < 1) regularization has attracted a great attention in the compressive sensing field, because it can obtain sparser solutions than the well-known l1 regularization. Recently, we developed an approximate general analytic thresholding representation for any lp regularization with 0 < p < 1. The derived thresholding representations are exact for the well-known soft-threshold filtering for l1 regularization and the hard-threshold filtering for l0 regularization. Because the lp regularization is a nonconvex problem, an iterative algorithm can only converge to local optima instead of the global optimum. In this paper, we propose an alternating iteration algorithm for computed tomography reconstruction in a thresholding form based on our general analytic thresholding representation for better convergent properties. The alternating iteration algorithm alternatively minimizes one l1 and one lp (0 < p < 1) regularized objective functions. While the lp regularization can help to find a sparser solution, the l1 regularization can help to monitor the solution not away from the global optimum. Both numerical simulations and phantom experiments are performed to evaluate the proposed alternating iteration algorithm. Compared with the lp (0 < p < 1) regularization using a single p, the proposed alternating iteration algorithm reduces more data measurements for accurate reconstruction and is more robust for projection noise.
关键词: Compressive sensing,lp regularization,least square solution,image reconstruction,alternating iteration,computed tomography
更新于2025-09-19 17:13:59
-
Predicting the fatigue life of an AlSi10Mg alloy manufactured via selective laser melting by using data from Computed Tomography
摘要: A modelling strategy is proposed to evaluate the influence of defect morphology on the fatigue limit of additively manufactured Al alloys by: (i) obtaining an x-ray micro-computed tomography (μ-CT) 3D image of the material, (ii) computing the Equivalent Inertia Ellipse of each individual pore, (iii) modelling the influence of the defect on the fatigue limit through the DSG approach and, (iv) 3D mapping the criticality of each individual defect. For this fatigue study, an AlSi10Mg alloy was manufactured by selective laser melting using sub-optimal deposition parameters in order to produce large lack-of-fusion defects. After a T6 heat treatment, tension-compression fatigue tests, with R = -1, were conducted on specimens oriented with their loading axis either parallel or normal to the Z-axis of the additive manufacturing equipment. Two samples were characterised before μ-CT testing in order to characterise the initial 3D defect population. Each sample was fatigued step by step in order to determine the fatigue limit. The fracture surface was then carefully observed using a scanning electron microscope (SEM) in order to identify the critical defect in the initial μ-CT image. A comparison with the fatigue results led to the following conclusions: (i) when the longest axis of the defect is perpendicular to the load axis, modelling the defect as an equivalent inertia prolate ellipse gives better results (5 % error on the fatigue limit) than modelling it as a simple equivalent sphere (22 % error on the fatigue limit), (ii) the prolate ellipse is not relevant when the longest axis of the defect is oriented along the loading axis; in this case an oblate equivalent ellipse should be used, (iii) the concept of ‘size’ for a complex 3D shaped defect should be linked to the inertia and the loading, (iv) with this approach, surface defects are shown to be more critical than internal ones for fatigue life and, (v) a 3D defect criticality map of the entire sample can be plotted to provide visual feedback on which defects are the most critical for fatigue life.
关键词: AlSi10Mg alloy,defect morphology,selective laser melting,fatigue life,Computed Tomography
更新于2025-09-19 17:13:59
-
Evaluation of internal defects generated in machine milled carbon fiber reinforced plastic using X-ray computed tomography
摘要: In this study, X-ray computed tomography (X-ray CT) was used to investigate internal defects generated on machine milled carbon fiber reinforced plastics (CFRP). Internal defects such as cracks, fractures, and deformation of the carbon fibers, which are invisible from the surface, were observed using the X-ray CT method. Defects were generated based on the machining method and direction of the fibers. A large number of defects were generated when using the conventional cut method along 45°, 90°, and the climb cut method along 90°. Few internal defects were observed when using the climb cut method along 45°; however, the machined surface was very rough. The mechanism for these phenomena was investigated by studying surface observations and cutting force, in addition to X-ray CT imaging. These results indicate that X-ray CT is a powerful tool for visualizing internal defects in CFRP, which differ significantly based on the direction of the fiber and machining method used.
关键词: Carbon fiber reinforced plastics,Surface roughness,Milling,Internal defect,X-ray computed tomography
更新于2025-09-16 10:30:52
-
Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan
摘要: Objective: Knowledge-based iterative model reconstruction (IMR) yields diagnostically acceptable image quality in low-dose static computed tomography (CT). We aimed to evaluate the feasibility of IMR in dynamic myocardial computed tomography perfusion (CTP). Methods: We enrolled 24 patients who underwent stress dynamic CTP using a 256-slice CT. Images were reconstructed using filtered back projection (FBP), hybrid IR, and IMR. Image quality and hemodynamic parameters were compared among three algorithms. Results: Qualitative image quality and contrast-to-noise ratio were significantly higher by IMR than by FBP or hybrid IR (visual score: 4.1 vs. 3.0 and 3.5; contrast-to-noise ratio: 12.4 vs. 6.6 and 8.4; P < 0.05). No significant difference was observed among algorithms in CTP-derived myocardial blood flow (1.68 vs. 1.73 and 1.70 mL/g/min). Conclusions: The use of knowledge-based iterative model reconstruction improves image quality without altering hemodynamic parameters in low-dose dynamic CTP, compared with FBP or hybrid IR.
关键词: iterative reconstruction,myocardial blood volume,myocardial blood flow,computed tomography perfusion,mean transit time
更新于2025-09-12 10:27:22