修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Adaptive backstepping approach for dc-side controllers of Z-source inverters in grid-tied PV system applications

    摘要: Z-source inverters (ZSIs) are single-stage power converters with both voltage buck and boost capabilities provided by the unique impedance network and the ability to operate during shoot-through states. This study proposes a novel non-linear adaptive backstepping method for dc-side controllers in a multi-loop control scheme of the ZSI in grid-tied photovoltaic (PV) systems. Despite the variability of the capacitor and inductor values in the ZSI impedance network, the proposed controller guarantees robust and stable operation under varying levels of PV irradiance and temperature. The shoot-through duty ratio of the ZSI is obtained directly from the output of an MPPT algorithm and the measured PV and inductor currents. This strategy overcomes the disadvantages of the conventional approach such as the non-minimum phase at the dc side of the ZSI. It also eliminates the need to linearise the voltage/current characteristics of the PV arrays and ZSI model. The ac-side controllers consist of an outer proportional–integral voltage controller and an inner deadbeat current controller to achieve unity power factor and stable capacitor voltage in spite of grid voltage fluctuations. The efficacy of the proposed adaptive backstepping controller and the multi-loop control scheme is validated by offline and hardware-in-the-loop real-time simulations.

    关键词: maximum power point tracking,Z-source inverters,adaptive backstepping control,grid-tied inverters,photovoltaic systems

    更新于2025-09-23 15:21:01

  • A Reconfigurable Solar Photovoltaic Grid-Tied Inverter Architecture for Enhanced Energy Access in Backup Power Applications

    摘要: In this paper, a photovoltaic (PV) reconfigurable grid-tied inverter (RGTI) scheme is proposed. Unlike a conventional GTI that ceases operation during a power outage, the RGTI is designed to act as a regular GTI in the on-grid mode but it is reconfigured to function as a DC-DC charge-controller that continues operation during a grid outage. During this period, the RGTI is tied to the battery-bank of an external UPS based backup power system to augment it with solar power. Such an operation in off-grid mode without employing high-bandwidth communication with the UPS is challenging, as the RGTI control must not conflict with the battery management system of the UPS. The hardware and control design aspects of this requirement are discussed in this paper. A battery emulation control scheme is proposed for the RGTI that facilitates seamless functioning of the RGTI in parallel with the physical UPS battery to reduce its discharge current. A system-level control scheme for overall operation and power management is presented to handle the dynamic variations in solar irradiation and UPS loads during the day, such that the battery discharge burden is minimized. The design and operation of the proposed RGTI system are independent of the external UPS and can be integrated with an UPS supplied by any manufacturer. Experimental results on a 4 kVA hardware setup validate the proposed RGTI concept, its operation and control.

    关键词: Solar PV,Battery,Grid-tied Inverters,dual-mode inverters,UPS,Closed-loop control

    更新于2025-09-12 10:27:22