  • Reproducibility of Central Corneal Thickness Measurements in Normal Eyes Using the Zeiss Cirrus 5000 HD-OCT and Pentacam HR

    摘要: Objectives: To determine the repeatability and reproducibility of Central Corneal Thickness (CCT) measurements using two different anterior segment imaging modalities, including those obtained with the new anterior segment lens attachments for the Cirrus 5000 HD-OCT. Methods: A total of 32 eyes from 16 normal volunteers (8 male, 8 female) were enrolled in this prospective study. CCT was measured by the same examiner using the Cirrus 5000 HD-OCT and Pentacam HR. The results of CCT obtained by each method were averaged and compared using t-test analysis. The agreement between the measurement methods was evaluated. Coefficient of Repeatability (CoR) and Intra-Class Correlation Coefficient (ICC) were computed. Results: The mean measurements taken with the Cirrus OCT anterior chamber lens (CCTAC), HD cornea lens (CCTHDC) and pachymetry scans (CCTPach) were 545.35 ± 31.02, 537.87 ± 26.82, and 532.04 ± 29.82 μm, respectively. The mean CCT obtained with the Pentacam (CCTPent) was 545.51 ± 30.71 μm. CCTPent were significantly higher than CCTHDC and CCTPach (p< 0.0001). In contrast, the CCTPent and CCTAC were similar (p=0.87). CCT, as evaluated by the two different instruments, showed excellent correlation (r > 0.98, p< 0.0001) with an ICC > 0.99 (95% CI, 0.97 – 0.99). CoR was the highest for CCTPach (3.7 ± 1.4, 95% CI (3.0- 4.6)). Conclusion: CCT measurements from the Cirrus OCT using the new anterior segment lens attachments and the Pentacam HR are highly correlated. This should allow the use of a standardized correction factor if necessary to inter-relate the measurements between the two devices.

    关键词: Imaging,Central corneal thickness,Cornea,Optical coherency tomography,Scheimpflug technology,Pachymetry

    更新于2025-09-23 15:21:01

  • Evaluation of Corneal Epithelial Thickness Imaged by High Definition Optical Coherence Tomography in Healthy Eyes

    摘要: Purpose: To evaluate corneal epithelial thickness (CET) and corneal thickness (CT) in healthy eyes using spectral domain optical coherence tomography. Methods: Thirty-six healthy eyes were imaged using the Cirrus high-definition (HD)-optical coherence tomography device. The average CET and CT were assessed using Cirrus Review Software within predefined concentric corneal ring-shaped zones. Specific regions of CET (superior, inferior, temporal, nasal, superonasal, inferotemporal, superotemporal, and inferonasal) were also assessed. The difference between zones was compared between males and females. Results: The average CET was 48.3, 47.1, 46.1, and 45.8 mm in the 4 concentric zones (0–2, 2–5, 5–7, and 7–9 mm), respectively (P < 0.001). The average CT was 533.5, 550.8, and 579.4 mm in the 3 zones (0–2, 2–5, and 5–7 mm), respectively (P < 0.001). There was no statistically significant correlation between CET and CT in any of the measured zones. Males had thicker corneas than did females in each of the 3 CT zones (P < 0.05), but CET did not differ significantly. The CET superonasal–inferotemporal in 2.0 to 5.0 mm and CET superotemporal–inferonasal in 5.0- to 7.0-mm zones were significantly thinner in males than in females (?1.15 vs. 0.9 mm, ?3.5 vs. ?1.9 mm), respectively (P < 0.05). Conclusions: Optical coherence tomography-based analysis of CET reveals that it is thinner in the periphery, whereas the total corneal thickness is greater. Although total CT seems to be influenced by sex, CET is not. Regional and sex-based variations in CT may need to be considered when assessing corneal and epithelial alterations in the setting of disease.

    关键词: corneal thickness,optical coherency tomography,imaging,corneal epithelial thickness