- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Thermal Mapping of a Lithium Polymer Batteries Pack with FBGs Network
摘要: In this paper, a network of 37 fiber Bragg grating (FBG) sensors is proposed for real-time, in situ, and operando multipoint monitoring of the surface temperature distribution on a pack of three prismatic lithium polymer batteries (LiPBs). Using the network, a spatial and temporal thermal mapping of all pack interfaces was performed. In each interface, nine strategic locations were monitored by considering a three-by-three matrix, corresponding to the LiPBs top, middle and bottom zones. The batteries were subjected to charge and discharge cycles, where the charge was carried out at 1.0 C, whereas the discharge rates were 0.7 C and 1.4 C. The results show that in general, a thermal gradient is recognized from the top to the bottom, but is less prominent in the end-of-charge steps. The results also indicate the presence of hot spots between two of the three batteries, which were located near the positive tab collector. This occurs due to the higher current density of the lithium ions in this area. The presented FBG sensing network can be used to improve the thermal management of batteries by performing a spatiotemporal thermal mapping, as well as by identifying the zones which are more conducive to the possibility of the existence of hot spots, thereby preventing severe consequences such as thermal runaway and promoting their safety. To our knowledge, this is the first time that a spatial and temporal thermal mapping is reported for this specific application using a network of FBG sensors.
关键词: in situ monitoring,lithium polymer batteries pack,FBGs network,safety,thermal mapping
更新于2025-09-23 15:22:29
-
Characterization of CMP Slurries Using Densitometry and Refractive Index Measurements
摘要: We investigated the possibility of employing refractive index (RI) measurements for inline incoming slurry control at the point of use (POU), as an alternative to the widespread densitometry method. As such, it became necessary to determine if RI could detect smaller changes in slurry composition and, therefore, provide a tighter control. Three industrially-relevant silica-based slurries, namely, Fujimi PL-7106, Klebosol 1501-50, and CMC W7801, were characterized using both densitometry and RI measurements. Initial solutions of the three slurries were prepared and increasingly small amounts of ultrapurified water (UPW) were added to study the change in slurry properties. Results showed that both density and RI decreased linearly with the addition of water for all three slurries, with the 1501-50 being the most sensitive to water addition. A linear correlation between the two properties was found, with R2 values that exceeded 0.95 in all cases. Furthermore, the approximate limit of detection of both metrology tools was estimated based on the slope of the fitting line and resolution. When compared to densitometry, RI was found to be the far superior method for detecting smaller changes in water concentration.
关键词: semiconductor technology,slurry characterization,in-line monitoring and control,chemical mechanical planarization
更新于2025-09-23 15:22:29
-
Tests of a New Drowsiness Characterization and Monitoring System Based on Ocular Parameters
摘要: Drowsiness is the intermediate state between wakefulness and sleep. It is characterized by impairments of performance, which can be very dangerous in many activities and can lead to catastrophic accidents in transportation or in industry. There is thus an obvious need for systems that are able to continuously, objectively, and automatically estimate the level of drowsiness of a person busy at a task. We have developed such a system, which is based on the physiological state of a person, and, more specifically, on the values of ocular parameters extracted from images of the eye (photooculography), and which produces a numerical level of drowsiness. In order to test our system, we compared the level of drowsiness determined by our system to two references: (1) the level of drowsiness obtained by analyzing polysomnographic signals; and (2) the performance of individuals in the accomplishment of a task. We carried out an experiment in which 24 participants were asked to perform several Psychomotor Vigilance Tests in different sleep conditions. The results show that the output of our system is well correlated with both references. We determined also the best drowsiness level threshold in order to warn individuals before they reach dangerous situations. Our system thus has significant potential for reliably quantifying the level of drowsiness of individuals accomplishing a task and, ultimately, for preventing drowsiness-related accidents.
关键词: drowsy driving,drowsiness,photooculography,psychomotor vigilance test,monitoring,polysomnography
更新于2025-09-23 15:22:29
-
Quantifying Multi-Decadal Change of Planted Forest Cover Using Airborne LiDAR and Landsat Imagery
摘要: Continuous monitoring of forest cover condition is key to understanding the carbon dynamics of forest ecosystems. This paper addresses how to integrate single-year airborne LiDAR and time-series Landsat imagery to derive forest cover change information. LiDAR data were used to extract forest cover at the sub-pixel level of Landsat for a single year, and the Landtrendr algorithm was applied to Landsat spectral data to explore the temporal information of forest cover change. Four different approaches were employed to model the relationship between forest cover and Landsat spectral data. The result shows incorporating the historic information using the temporal trajectory fitting process could infuse the model with better prediction power. Random forest modeling performs the best for quantitative forest cover estimation. Temporal trajectory fitting with random forest model shows the best agreement with validation data (R2 = 0.82 and RMSE = 5.19%). We applied our approach to Youyu county in Shanxi province of China, as part of the Three North Shelter Forest Program, to map multi-decadal forest cover dynamics. With the availability of global time-series Landsat imagery and affordable airborne LiDAR data, the approach we developed has the potential to derive large-scale forest cover dynamics.
关键词: afforestation,forest inventory,Three-North Shelter Forest Program,time-series,forest monitoring
更新于2025-09-23 15:22:29
-
26.1%-efficient POLO-IBC cells: Quantification of electrical and optical loss mechanisms
摘要: We present experimental results for interdigitated back contacted (IBC) solar cells with passivating POLO contacts for both polarities with a nominal intrinsic poly‐Si region between them. We reach efficiencies of 26.1% and 24.9% on a 1.3 Ω cm and 80 Ω cm p‐type FZ wafer and 24.6% on a 2 Ω cm n‐type Cz wafer, respectively. The initially measured implied efficiency potentials of the cells after passivating the surfaces are very similar, namely, 26.8%, 26.8%, and 26.4%, respectively. We attribute the difference between the efficiency potential and the final current‐voltage measurement to degradation, perimeter, and series and shunt resistance losses, which we quantify by lifetime measurements. With these measurements in combination with a finite element simulation, we determine the surface recombination velocity in the nominal intrinsic poly‐Si region to be in the range from 13 to 21 cm s?1. Using the same approach, we analyze the increase of the front surface recombination velocity during cell processing from 2 to 10 cm s?1 for the 1.3 Ω cm and from 0.5 to 2.3 cm s?1 for the 80 Ω cm. This leads to the fact that cells fabricated on lowly doped bulk material are more vulnerable to a process‐induced degradation of the surface passivation quality. We further determine the theoretical limits of the cells by firstly idealizing the recombination (28% for 1.3 Ω cm and 28.2% for 80 Ω cm) and secondly also idealizing the optics of the solar cells (29.4% and 29.5%).
关键词: IBC solar cells,efficiency potential,lifetime monitoring,POLO,passivating contacts
更新于2025-09-23 15:22:29
-
[IEEE 2018 20th International Conference on Transparent Optical Networks (ICTON) - Bucharest (2018.7.1-2018.7.5)] 2018 20th International Conference on Transparent Optical Networks (ICTON) - Soft Failure Localization in Elastic Optical Networks
摘要: Soft failure localization to early detect service level agreement violations is of paramount importance in elastic optical networks (EONs), while it allows anticipating possible hard failure events. Nowadays, effective and automated solutions for soft failure localization during lightpaths’ commissioning testing and operation are still missing. In this paper, we focus on presenting soft failure localization algorithms based on two different active monitoring techniques. First, the Testing optIcal Switching at connection SetUp timE (TISSUE) algorithm is proposed to localize soft failures during commissioning testing phase by elaborating the estimated bit-error rate (BER) values provided by low-cost optical testing channel (OTC) modules. Second, the FailurE causE Localization for optIcal NetworkinG (FEELING) algorithm is proposed to localize failures during lightpath operation using cost-effective optical spectrum analyzers (OSAs) widely deployed in network nodes. Results are presented to validate both algorithms in the event of several soft failures affecting lasers and filters.
关键词: machine learning algorithms,soft failure localization,monitoring and data analytics
更新于2025-09-23 15:22:29
-
Epidermis inspired ultrathin 3D cellular sensors array for self-powered biomedical monitoring
摘要: Sensing devices with wearability would open the door to many advanced applications including soft robotics, artificial intelligence and healthcare monitoring. Here, inspired by the configuration of human epidermis, we present a flexible three-dimensional (3D) cellular sensor array (CSA) via a one-step thermally induced phase separation method. The CSA was framed by 3D cellular electret with caged piezoelectric nanoparticles, which was ultrathin (80 μm), lightweight and high mechanically durable. For biomedical sensing, the 3D-CSA holds a decent pressure sensitivity up to 0.19 V kPa-1 with a response time of less than 16 ms. Owing to its rigid structural symmetry, the 3D-CSA could be identically operated from both sides, and it was demonstrated to successfully measure the human heartbeat, detect the eye ball motion for sleeping quality monitoring, as well as tactile image. Mimicking the functionalities of human skin with a self-powered operation feature, the 3D-CSA was expected to represent a substantial advancement in wearable electronics for healthcare.
关键词: ultrathin,biomedical monitoring,self-powered,cellular sensors array,epidermis
更新于2025-09-23 15:21:21
-
Deep-learning based surface region selection for deep inspiration breath hold (DIBH) monitoring in left breast cancer radiotherapy
摘要: Deep inspiration breath hold (DIBH) with surface supervising is a common technique for cardiac dose reduction in left breast cancer radiotherapy. Surface supervision accuracy relies on the characteristics of surface region. In this study, a convolutional neural network (CNN) based automatic region-of-interest (ROI) selection method was proposed to select an optimal surface ROI for DIBH surface monitoring. The curvature entropy and the normal of each vertex on the breast cancer patient surface were calculated and formed as representative maps for ROI selection learning. 900 ROIs were randomly extracted from each patient’s surface representative map, and the corresponding rigid ROI registration errors (RE) were calculated. The VGG-16 (a 16-layer network structure developed by Visual Geometry Group(VGG) from University of Oxford) pre-trained on a large natural image database ImageNet were fine-tuned using 27 thousand extracted ROIs and the corresponding RE from thirty patients. The RE prediction accuracy of the trained model was validated on additional ten patients. Satisfactory RE predictive accuracies were achieved with the root mean square error (RMSE)/mean absolute error (MAE) smaller than 1mm/0.7mm in translations and 0.45°/0.35° in rotations, respectively. The REs of the model selected ROIs on ten testing cases is close to the minimal predicted RE with mean RE differences <1mm and <0.5° for translation and rotation, respectively. The proposed RE predictive model can be utilized for selecting a quasi-optimal ROI in left breast cancer DIBH radiotherapy (DIBH-RT).
关键词: DIBH,ROI selection,transfer learning,motion monitoring
更新于2025-09-23 15:21:21
-
Li-Tect: 3D Monitoring and Shape Detection using Visible Light Sensors
摘要: In this paper, we propose Li-Tect, an algorithm to detect the shape of an object located in an indoor environment using low cost optical elements through sensing the environment's light. The algorithm analyzes, relying on the predictability of optical propagation paths, how much light is expected to propagate in the absence of obstructions caused by the presence of an object. Then, based on the received light when the object is in the room, the algorithm infers the shape of the object. In addition, the algorithm considers the reflected paths from surfaces in order to determine the object's estimated shape. We study five different scenarios characterized by different levels of complexity, room sizes and a range of reflection nodes. The algorithm is also tested in a real prototype where several experiments are carried out in two scenarios to demonstrate the capabilities of Li-Tect in two and three dimensional monitoring and shape detection cases. Finally, the results show that the shape and the detection of objects in the scenarios can be easily acquired with high accuracy, even if the number of transceivers is reduced.
关键词: Visible Light Sensors,Ray Tracing,Monitoring,Visible Light Communications,Shape Detection
更新于2025-09-23 15:21:21
-
A New Approach to Guided Wave Ray Tomography for Temperature-Robust Damage Detection Using Piezoelectric Sensors
摘要: In this paper, a new approach to guided wave ray tomography for temperature-robust damage detection with time-of-flight (TOF) temperature compensation is developed. Based on the linear relationship between the TOF of a guided wave and temperature, analyses show that the TOF of the baseline signal can be compensated by the temperature measurement of the inspected materials without estimating the temperature compensation parameters. The inversion is based on the optimization of the TOF misfit function between the inspected and compensated baseline TOFs of the guided waves, and is applied by the elastic net penalty approach to perform thickness change mapping in a structural health monitoring (SHM) application. Experiments that are conducted in isotropic plates by piezoelectric sensors demonstrate the effectiveness of the proposed method. According to the results, our approach not only eliminates the artefacts that are caused by a temperature variation from 25 ?C to 70 ?C but also provides more accurate and clearer imaging of damage than conventional ray tomography methods.
关键词: TOF,ray tomography,piezoelectric sensors,guided wave,structural health monitoring,temperature compensation
更新于2025-09-23 15:21:21