oe1(光电查) - 科学论文

10 条数据
?? 中文(中国)
  • Green Fluorescent Protein-Based Glucose Indicators Report Glucose Dynamics in Living Cells

    摘要: Glucose is the most important energy source for living animals. Here, we developed a series of single fluorescent protein (FP)-based glucose indicators, named as "Green Glifons", to understand the hierarchal and mutual relationships between molecules involved in energy metabolism. Three indicators showed a different EC50 for glucose (50 μM, 600 μM and 4,000 μM), producing a ~7-fold change in fluorescence intensity in response to glucose. The indicators could visualize glucose dynamics in the cytoplasm, plasma membrane, nucleus and mitochondria of living HeLa cells and in vivo, in the pharyngeal muscle of C. elegans and could measure murine blood glucose levels. Finally, the indicators were applicable to dual-color imaging, revealing the dynamic interplay between glucose and Ca2+ in mouse pancreatic MIN6 m9 β cells. We propose that these indicators will facilitate and contribute to in vivo and multi-color imaging of energy metabolism.

    关键词: biosensors,artificial sweeteners,dual-color imaging,C. elegans,live cell imaging,glucose,blood glucose level,fluorescent protein

    更新于2025-11-21 11:24:58

  • Prediction Quality of Glucose Trend Indicators in Two Continuous Tissue Glucose Monitoring SystemsParts of these data were previously presented at the 53rd Annual Meeting of the European Association for the Study of Diabetes, September 11–15, 2017, Lisbon, Portugal.

    摘要: Background: Continuous interstitial glucose monitoring (CGM) systems often provide glucose trend indicators (e.g., arrows) in addition to current glucose values. These indicators are recommended to be used in therapeutic decisions, because they are ascribed predictive qualities by CGM system manufacturers and expert committees. This study assessed how reliably trend indicators match future glucose change, because such information is missing. Methods: In a clinical trial, two different CGM systems were used by 20 participants, with two sensors of each system per patient. Participants used the systems for 14 days with three study site visits (48 h each). During study site visits, glucose trend indicators, as displayed by the CGM systems, were recorded at least once per hour during daytime and once at night in a diary. In addition, CGM data were downloaded from the devices. Trend indicators were compared with glucose change calculated from CGM data >30 min after recording the trend indicator. Results: Approximately 60% of trend indicators matched the glucose change calculated from CGM data. More than 10% of trend indicators differed by at least two trend indicator categories. Focusing on trend indicators recorded around carbohydrate (CHO) intake and insulin deliveries resulted in approximately half of trend indicators matching the calculated glucose change. Conclusions: Trend indicators do not always match future glucose change, especially within the first few hours after CHO intake and insulin deliveries. Manufacturers’ labeling and recommendations should reflect this, so that CGM users can make informed decisions.

    关键词: Trend arrow,Trend indicator,Continuous glucose monitoring,Nonadjunctive use,Blood glucose monitoring replacement

    更新于2025-09-23 15:23:52

  • Power spectral density-based nearinfrared sub-band detection for noninvasive blood glucose prediction in both <i>in-vitro</i> and <i>in-vivo</i> studies

    摘要: Diabetes is a widespread and serious disease and noninvasive measurement has been in high demand. To address this problem, a power spectral density-based method was offered for determining glucose sensitive sub-bands in the nearinfrared (NIR) spectrum. The experiments were conducted using phantoms of different optical properties in-vitro conditions. The optical bands 1200–1300 nm and 2100–2200 nm were found feasible for measuring blood glucose. After that, a photoplethysmography (PPG)-based low cost and portable optical system was designed. It has six different NIR wavelength LEDs for illumination and an InGaAs photodiode for detection. Optical density values were calculated through the system and used as independent variables for multiple linear regression analysis. The results of blood glucose levels for 24 known healthy subjects showed that the optical system prediction was nearly 80% in the A zone and 20% in the B zone according to the Clarke Error Grid analysis. It was shown that a promising easy-use, continuous, and compact optical system had been designed.

    关键词: Noninvasive,led,blood glucose,power density.,nearinfrared,photoplethysmography

    更新于2025-09-23 15:23:52

  • Overcoming Individual Discrepancies, a Learning Model for Non-Invasive Blood Glucose Measurement

    摘要: Non-invasive Glucose Measurement (NGM) technology makes great sense for the blood glucose management of patients with hyperglycemia or hypoglycemia. Individual Discrepancies (IDs), e.g., skin thickness and color, not only block the development of NGM, but also become the reason why NGM cannot be widely used. To solve this problem, our solution is designing an individual customized NGM model that can measure these discrepancies through multi-wavelength and tune parameters for glucose estimating. In this paper, an NGM prototype is designed, and a learning model for glucose estimating with automatically parameters tuning based on Independent Component Analysis (ICA) and Random Forest (RF) is presented. The clinic trial proves that the correlation coefficient between estimation and reference Blood Glucose Concentration (BGC) can reach 0.5 after merely 10 times of learning, and rise to 0.8 after about 60 times of learning.

    关键词: Independent Component Analysis (ICA),random forest,non-invasive,blood glucose,diabetes

    更新于2025-09-23 15:22:29

  • Highly Sensitive Room-Temperature Sensor Based on Nanostructured K2W7O22 for Application in the Non-Invasive Diagnosis of Diabetes

    摘要: Diabetes is one of the most rapidly-growing chronic diseases in the world. Acetone, a volatile organic compound in exhaled breath, shows a positive correlation with blood glucose and has proven to be a biomarker for type-1 diabetes. Measuring the level of acetone in exhaled breath can provide a non-invasive, low risk of infection, low cost, and convenient way to monitor the health condition of diabetics. There has been continuous demand for the improvement of this non-invasive, sensitive sensor system to provide a fast and real-time electronic readout of blood glucose levels. A novel nanostructured K2W7O22 has been recently used to test acetone with concentration from 0 parts-per-million (ppm) to 50 ppm at room temperature. The results revealed that a K2W7O22 sensor shows a sensitive response to acetone, but the detection limit is not ideal due to the limitations of the detection system of the device. In this paper, we report a K2W7O22 sensor with an improved sensitivity and detection limit by using an optimized circuit to minimize the electronic noise and increase the signal to noise ratio for the purpose of weak signal detection while the concentration of acetone is very low.

    关键词: non-invasive,biomarker,ferroelectric property,blood glucose,volatile organic compound,acetone,nanostructured K2W7O22,diabetes

    更新于2025-09-23 15:21:21

  • Wearable-band Type Visible-Near Infrared Optical Biosensor for Non-invasive Blood Glucose Monitoring

    摘要: Diabetes is a worldwide-serious problem that can only be delayed or prevented by a regular monitoring of blood glucose (BG) concentration level. Continuous monitoring systems allow subjects to prepare the diabetes management strategy and prevent the long-term complications diseases. Until now, most studies utilize various biofluids such as sweat, tears and saliva that have serious unresolved setback such as expensive material, sensor stability, sensor calibration and long-settling time. Therefore, we developed a novel BG sensor which is cost efficient and highly wearable with a small data acquisition time window that allow a non-invasive, long-term continuous blood glucose monitoring (CGM) system. The novel biosensor exploits a unique information of the pulsatile to continuous components of the arterial blood volume pulsation during the change of blood glucose (BG) concentration at the wrist tissue. The reflected optical signal was measured in the combine visible-near infrared (Vis-NIR) spectroscopy. An in-vivo experiment which enclosed 12 volunteers in a two-hour modified carbohydrate-rich meals reached the average correlation coefficient (????) between the estimated and reference BG concentration of 0.86, with the standard prediction error (SPE) of 6.16 mg/dl. Moreover, the full-day experiment was also conducted to test the reliability of the proposed sensor. Results showed that the created model in the previous day, may estimate a full-day BG concentration which was done in next day with an adequate performance.

    关键词: Wearable Sensor,Optical Biosensor,Noninvasive Measurement,Visible-Near Infrared Spectroscopy,Diabetes,Continuous Blood Glucose Monitoring

    更新于2025-09-19 17:15:36

  • Spectral Interrogation based SPR Sensor for Blood Glucose Detection with Improved Sensitivity and Stability

    摘要: A sensor chip for specific detection of blood glucose was developed. The sensor utilized a surface-plasmon-resonance (SPR) setup on a prism based Kretschmann configuration utilizing spectral interrogation scheme. Self-assembled monolayers (SAMs) based preparation provided the chip stability due to covalent bonds and hence it can be reused for multiple times. Such a scheme can be advantageous in continuous monitoring of blood glucose, without changing the chip. Control experiments were performed without molecular recognition layer to confirm the performance of the sensor. Furthermore, the measurements were performed on blood serums and compared with that of a conventional glucometer. The present sensor has the advantages of improved sensitivity (0.14 nm/(mg/dl)) and stable response for 3 months, which are better compared to existing reports.

    关键词: Blood glucose,Self assembled monolayers,Surface plasmon resonance,Biosensor

    更新于2025-09-19 17:15:36

  • Noninvasive blood glucose detection by Quantum Cascade Laser

    摘要: Quantum Cascade Laser (QCL) was invented in late 90s as a promising mid-infrared light source and contributed to the field of industry, military, medicine, and biology. The room temperature operation, watt-level output power, compact size, and wide tuning capability of this laser advanced the field of noninvasive blood glucose detection by exploring transmission, absorption, and photoacoustic spectroscopy. This review provides a complete overview of the recent progress and technical details of these spectroscopy techniques, using QCL as an infrared light source for detecting blood glucose concentration for diabetic patients.

    关键词: transmission spectroscopy,Quantum Cascade Laser,mid-infrared,noninvasive blood glucose detection,photoacoustic spectroscopy,absorption spectroscopy

    更新于2025-09-19 17:13:59

  • [IEEE 2018 IEEE 20th International Conference on e-Health Networking, Applications and Services (Healthcom) - Ostrava, Czech Republic (2018.9.17-2018.9.20)] 2018 IEEE 20th International Conference on e-Health Networking, Applications and Services (Healthcom) - Investigation on Dielectric Properties of Glucose Aqueous Solutions at 500 KHz-5MHz for Noninvasive Blood Glucose Monitoring

    摘要: Noninvasive blood glucose monitoring (NBGM) provides patient with diabetes a prospective approach with the characteristics of painless and sustainable monitoring. In this study, the dielectric properties of glucose aqueous solutions, namely, deionized water solutions and saline solutions were studied. Specifically, the conductivity and the dielectric constant were measured by using impedance analyzer in the frequencies range of 500 KHz to 5MHz at 25°C. The results showed that both the dielectric constant and the conductivity for the two types of glucose aqueous solutions decreased with the increase of glucose concentration in the above frequency band. By comparing the two solutions with human blood, it was found that the dielectric properties of physiological saline are closer to that of human blood. In the study, saline solution was adopted as research object. In order to formulate the relationship between the dielectric properties of saline solutions and glucose concentration, the third-order Cole-Cole model for each glucose concentration was developed and the coefficient of determination R2 was as higher as 0.99. In addition, a second-order polynomial is used to model the glucose concentration dependence for the Cole–Cole parameters. The result indicates that the NBGM at low frequencies has potentials in practical applications.

    关键词: dielectric properties,Cole-Cole parameters,glucose concentration,Noninvasive blood glucose monitoring

    更新于2025-09-10 09:29:36

  • Transmission Spectroscopy in Noninvasive Blood Glucose Measurement

    摘要: The use of laser diodes and photodiodes in transmission spectroscopy has some effects (temperature, time, spectral, and spatial) reducing the accuracy of glucose measurement. These effects can be reduced by using a (1600 ± 3) nm laser in combination with fixation and occlusion of the tissue area under examination. In this work, a method is suggested that allows spatial displacements of the system to be taken into account. A number of methods for reducing the effect of the thermal drift of the diodes are also suggested. A portable noninvasive optical glucose meter implemented using these methods provides high clinical performance: more than 97% of the measurements are in the A and B zones of the Parkes error grid.

    关键词: photodiodes,transmission spectroscopy,noninvasive blood glucose measurement,laser diodes,thermal drift,spatial displacements

    更新于2025-09-04 15:30:14