- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Size and shape effects on the field enhancement induced at a silver triangular tip
摘要: A computational study is conducted on the near field enhancement induced by localized surface plasmon resonance (LSPR) around a silver nanotape of various sizes and shapes. The results show the consistent dominance of the dipole field generated at the rectangular Ag nanotape surfaces of various lengths by a normal incident electromagnetic plane wave of polarization along the long edge. The dipole field is further shown to exhibit monotonous spectral redshifts and increased magnitudes with increased length (?) of the rectangular nanotape. In contrary, the spectral peak and the field magnitude do not show the simple consistent variations with varied apex angle (θ) of the triangular nanotape. The calculated result for the triangular tape does exhibit the largely concentrated near field magnitude at the tip. It is found that a remarkable enhancement factor of 107 is attained at θ = 45° and ? = 50 nm.
关键词: field enhancement,silver triangular tip,localized surface plasmon resonance,computational study
更新于2025-09-04 15:30:14
-
Novel luminescent paper based calix[4]arene chelation enhanced fluorescence- photoinduced electron transfer probe for Mn2+, Cr3+ and F-
摘要: A novel structurally simple calix[4]arene attached 1-aminoanthraquinone associated lower rim calix[4]arene conjugate was synthesized and has been used as turn on/off/on fluorescence probe for Mn2+, Cr3+ and F-. This chelation enhanced fluorescence - photoinduced electron transfer (CHEF-PET) based TAAC probe has been applied for its analytical application in real samples such as Mn2+ from blood serum, Cr3+ and F- from industrial effluent with 94 - 99 % recovery. The limit of detection of this sensor is found to be 11 nM for Mn2+, 4 nM for Cr3+ and 19 nM for F- with the concentration range of 0-120 nM. Further, we report an easy-to-use, low cost and disposable paper-based sensing device for rapid chemical screening of Mn2+, Cr3+ and F-. The device comprises fluorescent sensing probes embedded into a nitrocellulose matrix where the resonance energy transfer phenomenon seems to be the sensing mechanism. It opens up new opportunities for simple and fast screening in remote settings where sophisticated instrumentation is not always available. The MOPAC-2016 software package has been used to optimize the TAAC using PM7 well established method and calculates the HOMO-LUMO energy band gap for structure TAAC and TAAC with Mn2+, Cr3+ and F- ion based structures.
关键词: paper based analytical device,computational study,CHEF,PET,calix[4]arene
更新于2025-09-04 15:30:14