修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Raman spectroscopic analysis of high molecular weight proteins in solution – considerations for sample analysis and data pre-processing

    摘要: This study explores the potential of Raman spectroscopy, coupled with multivariate regression techniques and a protein separation technique (ion exchange chromatography), to quantitatively monitor diagnostically relevant changes in high molecular weight proteins in liquid plasma. Measurement protocols to detect the imbalances in plasma proteins as an indicator of various diseases using Raman spectroscopy are optimised, such that strategic clinical applications for early stage disease diagnostics can be evaluated. In a simulated plasma protein mixture, concentrations of two proteins of identified diagnostic potential (albumin and fibrinogen) were systematically varied within physiologically relevant ranges. Scattering from the poorly soluble fibrinogen fraction is identified as a significant impediment to the accuracy of measurement of mixed proteins in solution, although careful consideration of pre-processing methods allows construction of an accurate multivariate regression prediction model for detecting subtle changes in the protein concentration. Furthermore, ion exchange chromatography is utilised to separate fibrinogen from the rest of the proteins and mild sonication is used to improve the dispersion and therefore quality of the prediction. The proposed approach can be expeditiously employed for early detection of pathological disorders associated with high or low plasma/serum proteins.

    关键词: sonication,pre-processing,disease diagnostics,Raman spectroscopy,plasma proteins,ion exchange chromatography,multivariate regression

    更新于2025-09-19 17:15:36

  • Silica bead-based microfluidic device with integrated photodiodes for the rapid capture and detection of rolling circle amplification products in the femtomolar range

    摘要: The rapid and sensitive detection of specific nucleic acid sequences at the point-of-care (PoC) is becoming increasingly in demand for a variety of emergent biomedical applications ranging from infectious disease diagnostics to the screening of antimicrobial resistance. To meet such demand, considerable efforts have been invested towards the development of portable and integrated analytical devices combining microfluidics with miniaturized signal transducers. Here, we demonstrate the combination of rolling circle amplification (RCA)-based nucleic acid amplification with an on-chip size-selective trapping of amplicons on silica beads (~8 nL capture chamber) coupled with a thin-film photodiode (200 × 200 μm area) fluorescence readout. Parameters such as the flow rate of the amplicon solution and trapping time were optimized as well as the photodiode measurement settings, providing minimum detection limits below 0.5 fM of targeted nucleic acids and requiring only 5 μL of pre-amplified sample. Finally, we evaluated the analytical performance of our approach by benchmarking it against a commercial instrument for RCA product (RCP) quantification and further investigated the effect of the number of RCA cycles and elongation times (ranging from 10 to 120 minutes). Moreover, we provide a demonstration of the application for diagnostic purposes by detecting RNA from influenza and Ebola viruses, thus highlighting its suitability for integrated PoC systems.

    关键词: Microfluidics,Infectious disease diagnostics,Silica microbeads,Photodiodes,Rolling circle amplification

    更新于2025-09-04 15:30:14