修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Spatial heterodyne spectroscopy for high speed measurements of Stark split neutral beam emission in a high temperature plasma

    摘要: Measurement of electrostatic potential, or local electric field, turbulence is a critical missing component in validating nonlinear turbulence and transport simulations of fusion plasmas. A novel diagnostic is being developed for measuring local electric field fluctuations, ?E(r, t), via high-speed measurements of the light emitted from a hydrogenic neutral beam. It exploits the proportionality of the spectral line splitting from the Motional Stark Effect to the total electric field experienced by the neutral atom at the excitation site. The measurement is localized by the usual cross-beam geometry of beam-spectroscopy measurements. The corner stone of the diagnostic is a high spectral resolution, high etendue spatial heterodyne spectrometer (SHS). A SHS design with high etendue (~5 mm2 sr) and resolution (~0.14 nm) meets the formidable spectrometer requirements. Field tests of the spectrometer at the DIII-D tokamak demonstrate that the beam emission spectrum produced by the SHS agrees with that of a traditional spectrometer and that the measured flux is adequate for turbulence studies.

    关键词: Stark split neutral beam emission,electric field fluctuations,spatial heterodyne spectroscopy,turbulence diagnostics,high temperature plasma

    更新于2025-09-23 15:21:21

  • Versitile X-ray diagnostics of laser-produced high-temperature plasmas using an ultra-high luminosity spectrometer

    摘要: Versitile diagnostics of high-temperature magnesium laser-produced plasmas is performed using an ultra-high luminosity X-ray focusing crystal spectrometer. The plasmas are produced by focusing nanosecond laser pulses (0.53 mm, 1 J, 2 ns) on a massive magnesium target. The absolute intensities and X-ray yields are measured for the resonance lines of H- and He-like ions (spectral range: D?l = 8 –10 ?), the electron temperature of plasmas is determined (range: Te = 200 – 550 eV), and the behaviour of these parameters is established in a broad range of laser pulse energy EL (10 mJ – 1 J). This approach permits the parameters of laser-plasma radiation sources to be monitored in real time in a wide intensity range (difference in intensity: over 104) and in a broad range of plasma parameters.

    关键词: laser-produced plasmas,X-ray spectrometers,high-temperature plasma diagnostics,X-ray spectroscopy and metrology,multiply charged ions

    更新于2025-09-16 10:30:52