- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Effect of phototherapy on dentin bond strength and microleakage when bonded to resin with different conditioning regimes
摘要: Aim To assess the efficacy of phototherapy on bond strength and microleakage of bulk fill composites in comparison to conventional dentin surface treatments. Materials and Methods Ninety human third molars were divided into 3 groups (n=30 each) according to surface conditioning treatment. Group 1 (Etch and Bond) EB, group 2 was treated with Er,Cr: YSGG (ECL) and group 3 was treated with a diode laser (DL). Based on the type of bulk fill resin composite, samples were divided into six sub-groups. In sub-group 1, 2 and 3 (n=15) build-up was done using ZirconCore (ZC) and these subgroups were named as EB-ZC, ECL-ZC and DL-ZC. In subgroup 4,5,6 (n=15) MulticCore Flow (MC) was used for core build-up and these subgroups were named as EB-MC, ECL-MC, DL-MC. For shear bond strength (SBS) all the samples were exposed to loads using a universal testing machine. Five samples each from all subgroups were immersed in methylene blue dye for 24hours prior to microleakage testing. Data were assessed using analysis of variance and Tukey multiple comparisons test. Results: Among all the groups the lowest bond strength was achieved in DL-ZC [10.45(0.459)]. Similarly, the highest bond strength was attained in EB-MC[17.84(0.925)]. The highest microleakage scores amongst different group was exhibited in DL-ZC [82.45(39.459)] whereas, the lowest microleakage scores were displayed in EB-MC [31.21(15.92)]. Conclusion: Phototherapy in the form of Er,Cr:YSGG laser showed comparable adhesive bond outcomes to conventional etch and bond dentin conditioning techniques. Moreover, Multicore bulk fill material showed better bond strength and microleakage scores than zirconium particle infiltrated bulk fill composite in the presence of dentin phototherapy.
关键词: dentine,bond strength,Cr: YSGG,microleakage,Er,bulk fill composite
更新于2025-09-23 15:23:52
-
Efficacy of phototherapy with different conventional surface treatments on adhesive quality of lithium disilicate ceramics
摘要: Aim: The aim of the present study was to evaluate shear bond strength (SBS) of LDC and resin composite in combination with phototherapy and different ceramic surface treatments. Materials and Method: Forty Lithium Disilicate Glass Ceramic (LDC) disks measuring (4x4x9mm) were fabricated. The specimens were randomly divided into four groups (n=10 each) according to the surface treatment. Group 1 HF+ Silane (Control); Group 2 HF+ Ultrasonic bath + Silane; Group 3 SECP (Self etch ceramic primer) and Group 4 phototherapy (Er, Cr: YSGG) + Silane. On each ceramic disk a resin build-up was done. For SBS the specimens were subjected to increasing load with a transversal velocity of 1ml/min on a universal testing machine on a ceramic resin interface. Failure mode was evaluated using digital microscope. The failure modes were divided into adhesive, cohesive and admixed interface. Data through bond strength testing was tabulated using statistical program for social science (SPSS). Means and standard deviations were compared using analysis of variance and Tukey's post hoc test (p<0.05) Results: The maximum and minimum bond strength was observed in group 2 [19.58(1.011)] and group 1 [17.14(1.122)] respectively. The bond strength among experimental group 1 [17.14 (1.122)] and group 4 [17.48(1.145)] were found to be comparable. Specimens in Group 2 displayed significantly higher bond strength among all experimental groups. Commonly adhesive failure mode was observed in the present study, with an incidence of 60%, 100% and 70% in groups 1,2 and 3 correspondingly Conclusion: Phototherapy using laser at frequency 30Hz and 4.5 W can be used as a surface conditioner for LDC alternate to HF acid. Conditioning of LDC using Self-etch ceramic primer showed better SBS outcomes as compared to phototherapy (Er, Cr: YSGG laser).
关键词: bond strength,microleakage,Phototherapy,lithium disilicate ceramics
更新于2025-09-23 15:22:29
-
Influence of phototherapy on adhesive strength and microleakage of bleached enamel bonded to orthodontic brackets: An Invitro study
摘要: Aim: The aim of the present in-vitro study was to explore bleached enamel reversal with phototherapy (Er,Cr:YSGG) when using two dissimilar bonding system to bond brackets on microleakage and shear bond strength. Material and Methods: Amongst one twenty samples, ninety samples were bleached using 35% hydrogen peroxide. After the bleaching procedure, the teeth were randomly divided into three groups according to surface conditioning treatment (n=30 each). Group 1: treated with Er,Cr:YSGG (ECL) Group 2: 10% sodium ascorbate (SA) and Group 3: Bleached only (BO). Based on the type of adhesive, specimens were further classified into eight subgroups. In subgroup 1,2,3 and no treatment (NT) (n=15) adhesive Transbond XT was applied on already etched surface and these subgroups were named as NT-TEP, BO-TEP, ECL-TEP and SA-TEP. Similarly, in subgroup 5,6,7 and NT specimens (n=15) were conditioned with Transbond Plus self-etching primer and these subgroups were named as NT-SEP, BO-SEP, ECL-SEP and SA-SEP. Samples from each subgroup were exposed to increasing load for evaluation of shear bond strength. Microleakage among subgroups were tested by immersing samples in Methylene blue prior one day. Analysis of variance and Tukey multiple comparisons test was used to assess data. Results: The maximum and minimum bond strength was observed in group NT-TEP [17.14(2.54)] and BO-SEP [6.14(0.215)] respectively. Samples conditioned with phototherapy ECL-TEP [16.14(1.231)] exhibited comparable bond strength to specimens conditioned with sodium ascorbate (SA-TEP) [16.72(1.298)]. Similarly, bond strength values of ECL-SEP [13.43(0.921)] and SA-SEP were comparable. The highest microleakage score was demonstrated in BO-SEP [83.21(38.21)] whereas, the lowest microleakage scores were displayed in NT-TEP [23.73(13.45)]. Conclusion: Er,Cr:YSGG phototherapy reversal on bleached enamel with etch and rinse adhesives has a potential to be used in clinical settings alternate to conventional sodium ascorbate when bonding orthodontic brackets.
关键词: Microleakage,Bleached enamel,Sodium Ascorbate,Phototherapy,Bond strength
更新于2025-09-23 15:22:29
-
Laser-Aided Enamel Conditioning: A Comparison of Microleakage Under Brackets Following Different Aging Procedures
摘要: Objective: To evaluate microleakage under the orthodontic adhesives applied following two version of erbium:yttrium aluminum garnet (Er:YAG) laser-aided enamel conditioning after thermal and thermomechanical simulators. Materials and Methods: A comparative analytical study based on metal braces bonded on the enamel of extracted teeth (n = 160) etched with acid, Er:YAG laser and Er:YAG laser with an X-Runner handpiece, and self-etch adhesives. An arch wire was ligatured to samples which were embedded in acrylic blocks by two with periodontal ligaments. The specimens were subdivided into two groups: those aged with thermal cycling and thermomechanical aging procedures. The samples were immersed in basic fuchsin solution (0.5%) for 24 h. Buccolingual sections were performed on the mesial and distal wings of the braces. The color penetration at the gingival and occlusal margins of the adhesive-bracket and enamel-adhesive was evaluated under a stereomicroscope. The median and mean values of microleakage in both groups were evaluated with Kruskal–Wallis and Mann–Whitney U tests (P < .05). Results: The highest microleakage was recorded in the gingival part of the samples aged with the thermomechanical aging procedure (P = .001). The amount of microleakage generally increased in the samples subjected to thermomechanical loading, but the only significant difference was recorded in the gingival part in each four different conditioning methods. Conclusion: Microleakage of the phosphoric acid-etched groups was recorded with lower values for both aging methods. Thermomechanical aging should be included to microleakage studies due to increased microleakage on gingival side for all etching groups.
关键词: thermomechanical aging,Chewing simulation in orthodontics,microleakage,X-Runner handpiece,Er:YAG Laser
更新于2025-09-16 10:30:52
-
Assessment of Microleakage of a Composite Resin Restoration in Primary Teeth Following Class III Cavity Preparation Using Er, Cr: YSGG laser: An In Vitro Study
摘要: Introduction: Marginal seal integrity is important for a successful adhesive dental restoration. Alterations caused by laser irradiation in the enamel and dentin surface can affect the marginal integrity of adhesive restorations. The aim of this study was to evaluate the microleakage of a composite resin restoration in primary teeth following laser irradiation of enamel and dentin. Methods: Forty freshly extracted sound human primary maxillary and mandibular anterior teeth were used in this study. The teeth were randomly divided into two groups (I and II), with 20 teeth in each. In group I, proximal cavities (Class III) were prepared using an airotor hand –piece and diamond bur. The cavities were etched for 15 seconds with 35% phosphoric acid gel, rinsed with water for 15 seconds, air dried and a bonding agent was applied onto the cavity surfaces and light cured for 20 seconds. The cavities were restored with composite resin and light cured for 40 seconds. In group II, proximal (Class III) cavities were prepared using Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) (Er,Cr:YSGG) (Biolaseiplus, wave length 2.78 μm). The cavity was then rinsed, air dried and without etching, a bonding agent was applied and light cured for 20 seconds. The cavities were restored in the same manner as that of group I. The treated teeth were mounted on acrylic resin blocks and were subjected to a thermocycling regimen. Following, the teeth were immersed in 2% methylene blue for 24 hours. The teeth were sectioned longitudinally in a bucco-lingual direction using a diamond disc at slow speed. The sections of all the groups were examined under a stereomicroscope for micro-leakage. Results: The mean scores for microleakage in group I was 1.95 ± 1.31 and in group II it was 1.4 ± 1.27. There was no significant difference between the two groups (P = 0.882). Conclusion: No significant difference in microleakage was noticed between the composite resin bonded to lased enamel and dentin and the teeth preparedwith conventional method.
关键词: laser,primary teeth,cavity preparation,dental,microleakage
更新于2025-09-11 14:15:04
-
Microleakage of conventional light-cure resin-based fissure sealant and resin-modified glass ionomer sealant after application of a fluoride varnish on demineralized enamel
摘要: Background International guidelines on the prevention of caries recommend sealing of the pits and fissures of the permanent molars. There is no evidence on which type of material is most effective on demineralized enamel. Aim To evaluate the microleakage of a conventional light-cured, resin-based fissure sealant (LCRBS), GrandiO Seal, and a resin-modified glass ionomer sealant (RMGIS), Vitremer, after application of a fluoride varnish, Bifluorid 12, on demineralized enamel. Design 80 human third molars were divided into eight groups. The groups combined the three study factors (1) type of enamel (intact or demineralized); (2) enamel non-varnished or varnished with Biflourid12; and (3) type of sealant (GrandiO Seal or Vitremer). The percentage of microleakage after thermocycling was measured using imaging analysis software. The Kruskal-Wallis plus Dunn tests were used to compare differences in microleakage in the different groups. Results The lowest microleakage was in the unvarnished groups, and was the same for GrandiO Seal and Vitremer. When varnish was applied, microleakage was greater in demineralized enamel than in intact enamel for both LCRBS and RMGIS. Conclusion The application of fluoride varnish on demineralized enamel increases the microleakage of both GrandiO Seal and Vitremer.
关键词: microleakage,demineralized enamel,resin-modified glass ionomer sealant,fluoride varnish,light-cure resin-based fissure sealant
更新于2025-09-04 15:30:14