- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
[IEEE 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018) - Paris, France (2018.7.8-2018.7.13)] 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018) - A High Precision Multi-Ratio Three-Stage Current Transformer (CT) for Loss Measurements of Extra High Voltage (EHV) Three-Phase Shunt Reactors with Test Voltages up to 1100 kV
摘要: An overview of the development and performance of special high precision multi-ratio three-stage CT and its application for loss measurement of EHV three-phase shunt reactors with AC test voltages up to 1100 kV at Royal SMIT Transformers are presented and discuss. It features current ratios of 500A/1A, 400A/1A, 300A/1A, 200A/1A, and 100A/1A with ratio errors within 3×10-6 in both magnitude and phase with burdens up to 1.0 ? and at power frequencies of 50 Hz - 60 Hz.
关键词: multi-ratio,ratio errors,multistage,Extra High Voltage (EHV),loss measurements,uncertainty,shunt reactor,three-stage,precision measurements
更新于2025-09-10 09:29:36