修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

143 条数据
?? 中文(中国)
  • Haab striae: Optical coherence tomographic analysis

    摘要: Purpose. — To study Haab striae in adults with primary congenital glaucoma and describe them by anterior segment optical coherence tomography, as well as analyze their evolution over the patient’s lifetime. Material and methods. — Three patients with primary congenital glaucoma were recruited, aged between 17 and 48 years old, with incidentally noted Haab striae on glaucoma consultation. They were studied by: slit lamp; anterior segment optical coherence tomography, Heidelberg Engineering Inc., Germany, (with anterior segment module) and Cirrus HD-OCT, Carl Zeiss Meditec, Dublin, California, USA (with 3D reconstruction); and specular biomicroscopy. The results obtained were contrasted with other studies performed in children. Results. — Rounded excrescences protruding towards the anterior chamber were found, as well as dense, irregular tissue between them. In addition, endothelial abnormalities (polymegathism and polymorphism) were found. These findings fit the evolution of those obtained in pediatric studies and remain stable in adult life. Conclusions. — Through noninvasive methods such as optical coherence tomography and specular biomicroscopy, it is possible to make the diagnosis and follow up these patients. The findings suggest posterior corneal topographic changes; additional studies on this subject may be necessary.

    关键词: Haab striae,Primary congenital glaucoma,Anterior segment optical coherence tomography,Corneal endothelium,Specular biomicroscopy

    更新于2025-09-23 15:22:29

  • A Comprehensive Model for Correcting RNFL Readings of Varying Signal Strengths in Cirrus Optical Coherence Tomography

    摘要: PURPOSE. To develop a model for the Cirrus HD-OCT that allows for the comparison of retinal nerve fiber layer (RNFL) thickness measurements with dissimilar signal strengths (SS) and accounts for test–retest variability. METHODS. Retinal nerve fiber layers were obtained in normals using the Cirrus optic disc cube 200 3 200 protocol during a single encounter. Five RNFL scans were obtained with a SS of 9 or 10. Diffusion lens filters were used to degrade SS to obtain five scans at each SS group of 7 or 8, 5 or 6, and 3 or 4. The relationship between average RNFL thickness and SS was established, and an equation was developed to allow for adjustment of an RNFL measurement had it been a SS of 7. Intravisit interclass correlation coefficient (ICC) and coefficient of variation (CV) parameter estimates for each SS group were calculated. Repeatability and upper tolerance limit were calculated as 1.96 3 =2 3 within-subject standard deviation (Sw) and 1.645 3 =2 3 Sw, respectively. RESULTS. There was a linear relationship between average RNFL and SS. RNFLadj ? RNFL (cid:2) 1.03*SS t 7.21 allows for the adjustment of RNFL readings to the same SS. Interclass correlation coefficients and CVs were good for all measurements down to SS of 3 or 4. Repeatability and upper tolerance limit were 5.24 and 4.40 lm, respectively. CONCLUSIONS. Our model adjusts RNFL readings based on SS and includes an upper tolerance limit of 5 lm. If validated, this model could improve the detection of real RNFL changes. Further study to validate this model should be performed before widespread use is adopted.

    关键词: glaucoma anterior segment,Cirrus OCT,signal strength,optical coherence tomography

    更新于2025-09-23 15:22:29

  • Optimizing a Portable ERG Device for Glaucoma Clinic: The Effect of Interstimulus Frequency on the Photopic Negative Response

    摘要: Purpose: The purpose of this study was to investigate the effect of interstimulus frequency on the photopic negative response (PhNR) in the clinical electroretinogram (ERG) in glaucoma and healthy eyes. Methods: Participants with open angle glaucoma (n = 15) and age-matched controls (n = 20) were recruited. Photopic ERGs were recorded in one eye using five frequencies (1–5 Hz) delivered in random order. ERGs were analyzed for changes to amplitude and timing between groups and interstimulus frequency. Coefficient of variation (CoV) was used to examine variability within recordings for each frequency. Results: While the a-wave and b-wave showed minimal alteration, the PhNR was highly sensitive to changes in interstimulus frequency. The PhNR signal was largest at 1 Hz and steadily diminished with higher frequencies in both control and glaucoma groups. Significant differences in PhNR amplitude were found between controls and glaucoma groups at 2 and 3 Hz. While 1 Hz delivered the largest PhNR, it also showed a significantly greater CoV compared to other frequencies. Conclusions: An interstimulus frequency of 2 Hz was optimal for recording the PhNR, creating a good balance between testing time and signal quality. A higher frequency could be used to further shorten clinical testing times; however, this may compromise its clinical utility by dampening the PhNR. Translational Relevance: Here we show the importance of considering flash interstimulus frequency when designing ERG protocols for recording the PhNR as while higher frequencies can shorten test times, they also have considerable effects on the PhNR.

    关键词: glaucoma,photopic negative response,electroretinogram

    更新于2025-09-23 15:22:29

  • Relationship between Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography and Visual Field Severity Indices

    摘要: Purpose: Though there are many reports regarding the structure-function relationship in glaucoma, they are too complicated to apply to the routine clinical setting. The aim of this study was to investigate the direct relationship between peripapillary retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and visual field (VF) severity indices computed by standard automated perimetry. Methods: This cross-sectional comparative study included 104 glaucomatous patients and 59 healthy subjects. Peripapillary RNFL thickness was measured by spectral domain (SD) and time domain (TD) OCTs. Four glaucoma VF severity indices, including mean deviation (MD), pattern standard deviation (PSD), Collaborative Initial Glaucoma Treatment Study (CIGTS) VF score, and Advanced Glaucoma Intervention Study (AGIS) VF score, were calculated using standard automated perimetry. The Pearson’s correlation coefficients (r) between the average and quadrants of peripapillary RNFL thicknesses and the four VF severity indices were calculated. Results: In glaucomatous eyes, the r value between the average RNFL thickness measured by SD OCT and each VF severity index were 0.562, -0.514, -0.577, and -0.567 for the MD, PSD, CIGTS VF score, and AGIS VF score, respectively (all p < 0.001). Among each quadrant, the inferior RNFL thickness showed the largest r value; 0.587, -0.552, -0.613, and -0.598 for the MD, PSD, CIGTS VF score, and AGIS VF score, respectively (all p < 0.001). Measurements by TD OCT showed similar strengths of association with SD OCT. Conclusions: Moderate correlation was identified between peripapillary RNFL thicknesses measured by SD/TD OCT and glaucoma VF severity indices. Among each quadrant, the inferior RNFL thickness showed the greatest association with glaucoma VF severity indices. There was no significant difference according to the type of VF severity index or the type of OCTs.

    关键词: Glaucoma,Retinal nerve fiber layer thickness,Optical coherence tomography,Visual fields

    更新于2025-09-23 15:22:29

  • Polybenzyl Glutamate Biocompatible Scaffold Promotes the Efficiency of Retinal Differentiation toward Retinal Ganglion Cell Lineage from Human-Induced Pluripotent Stem Cells

    摘要: Optic neuropathy is one of the leading causes of irreversible blindness caused by retinal ganglion cell (RGC) degeneration. The development of induced pluripotent stem cell (iPSC)-based therapy opens a therapeutic window for RGC degeneration, and tissue engineering may further promote the efficiency of differentiation process of iPSCs. The present study was designed to evaluate the effects of a novel biomimetic polybenzyl glutamate (PBG) scaffold on culturing iPSC-derived RGC progenitors. The iPSC-derived neural spheres cultured on PBG scaffold increased the differentiated retinal neurons and promoted the neurite outgrowth in the RGC progenitor layer. Additionally, iPSCs cultured on PBG scaffold formed the organoid-like structures compared to that of iPSCs cultured on cover glass within the same culture period. With RNA-seq, we found that cells of the PBG group were differentiated toward retinal lineage and may be related to the glutamate signaling pathway. Further ontological analysis and the gene network analysis showed that the differentially expressed genes between cells of the PBG group and the control group were mainly associated with neuronal differentiation, neuronal maturation, and more specifically, retinal differentiation and maturation. The novel electrospinning PBG scaffold is beneficial for culturing iPSC-derived RGC progenitors as well as retinal organoids. Cells cultured on PBG scaffold differentiate effectively and shorten the process of RGC differentiation compared to that of cells cultured on coverslip. The new culture system may be helpful in future disease modeling, pharmacological screening, autologous transplantation, as well as narrowing the gap to clinical application.

    关键词: induced pluripotent stem cells,retinal ganglion cells,tissue engineering,glaucoma,optic neuropathy,polybenzyl glutamate,electrospinning scaffold

    更新于2025-09-23 15:22:29

  • Baseline Detrending for the Photopic Negative Response

    摘要: Purpose: The photopic negative response (PhNR) of the light-adapted electroretinogram (ERG) holds promise as an objective marker of retinal ganglion cell function. We compared baseline detrending methods to improve PhNR repeatability without compromising its diagnostic ability in glaucoma. Methods: Photopic ERGs were recorded in 20 glaucoma and 18 age-matched control participants. A total of 50 brief, red-flashes (1.6 cd.s/m2) on a blue background (10 photopic cd/m2) were delivered using the RETeval device. Detrending methods compared were: (1) increasing the high-pass filter from 1 to 10 Hz and (2) estimating and removing the trend with an increasing polynomial (order from 1–10) applied to the prestimulus interval, prestimulus and postsignal interval, or the whole ERG signal. Coefficient of repeatability (COR%), unpaired Student’s t-test, and area under the receiver operating characteristic curve (AUC) were used to compare the detrending methods. Results: Most detrending methods improved PhNR test–retest repeatability compared to the International Society for Clinical Electrophysiology of Vision (ISCEV) recommended 0.3 to 300 Hz band-pass filter (COR% 6 200%). In particular, detrending with a polynomial (order 3) applied to the whole signal performed the best (COR% 6 44%) while achieving similar diagnostic ability as ISCEV band-pass (AUC 0.74 vs. 0.75, respectively). However, over-correcting with higher orders of processing can cause waveform distortion and reduce diagnostic ability. Conclusions: Baseline detrending can improve the PhNR repeatability without compromising its clinical use in glaucoma. Further studies exploring more complex processing methods are encouraged. Translational Relevance: Baseline detrending can significantly improve the quality of the PhNR.

    关键词: electroretinogram,baseline detrending,glaucoma,photopic negative response

    更新于2025-09-23 15:22:29

  • Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature

    摘要: Purpose: The aim of the study was to assess the influence of central corneal thickness (CCT) and corneal curvature in tonometry measurements taken by Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT). Methods: This was a prospective study of 185 eyes from 97 subjects, attending outpatient ophthalmology appointments, who underwent intraocular pressure measurements by GAT and Pascal DCT. CCT and corneal curvature were obtained using ultrasound pachymetry and Orbscan topography, respectively. All measurements were carried out among males and females during the period 2009–2012. Apart from the usual descriptive and exploratory data analysis, one-way analysis of variance and agreement analysis were performed, linear as well as intraclass correlation coefficients were estimated, and multiple scatter and Bland–Altman plots were produced. Results: Mean IOP measurements obtained were 17.21±4.10 mmHg by DCT and 13.23±4.07 mmHg by GAT. Mean difference between the GAT and DCT measurements was 3.88±2.8 mmHg. Mean CCT and corneal curvature were 522.78±52 μm and 43.83±2.9823 D, respectively. Conclusion: Intraocular pressure measured by GAT was consistently lower when compared with DCT, and this difference was greatest with thinner CCT. Flat corneas seem to influence GAT measurements compared to DCT.

    关键词: Pascal,glaucoma,tonometry,Goldmann

    更新于2025-09-23 15:22:29

  • Continuous 24-hour ocular dimensional profile recording in medically treated normal-tension glaucoma

    摘要: Purpose: To analyze the 24-hour ocular dimensional profile in normal-tension glaucoma (NTG) patients on medical treatment. Methods: Consecutive, medically treated NTG subjects were recruited from a university eye center. Subjects were on a mean of 1.7±0.7 types of antiglaucoma medications and 56.6% were on a prostaglandin analog. A contact lens-based sensor device was worn in one eye of NTG patients to record the intraocular pressure (IOP)-related profile for 24 hours, recording the following: variability from mean over 24 hours, nocturnally and diurnally, as well as the number of peaks and troughs diurnally and nocturnally. Results: In 18 NTG subjects, the nocturnal variability around the mean contact lens-based sensor device signal was 48.9% less than the diurnal variability around the mean. The number of peaks was 54.7% less during the nocturnal period than during the diurnal period. The rate of increase in the ocular dimensional profile when going to sleep was significantly greater than the rate of decrease upon waking (P<0.001). Conclusion: In medically treated NTG subjects, there was more variability in the IOP-related pattern during the daytime and there were fewer peaks during sleep.

    关键词: intraocular pressure,24-hour,normal tension glaucoma

    更新于2025-09-23 15:22:29

  • Effect of Apraclonidine and Diclofenac on Early Changes in Intraocular Pressure After Selective Laser Trabeculoplasty

    摘要: Précis: Adjuvant diclofenac and apraclonidine eye drop given in conjunction with selective laser trabeculoplasty (SLT) do not significantly impact medium-term intraocular pressure (IOP) reduction compared with placebo, but apraclonidine can be used to blunt immediate postlaser pressure spikes. Purpose: There is limited high-grade evidence guiding the choice of eye drops given before and after SLT. The authors chose to measure IOP during the first 24 hours, at 1 week, 6 weeks, and 6 months after SLT, and compare the effect of apraclonidine before SLT and diclofenac after SLT, with placebo. Materials and Methods: In this double-blind, randomized, placebo-controlled trial, patients with open-angle glaucoma or ocular hypertension referred for SLT were recruited between 2016 and 2018. Patients were randomized to receive either apraclonidine pre-SLT with placebo post-SLT, placebo pre-SLT with diclofenac post-SLT, or placebo before and after SLT. Results: Sixty eyes from 35 patients were treated with 360-degree SLT. Twenty-four-hour IOP measurements with patient self-monitoring after SLT demonstrated a moderate IOP spike at 1 hour and 2 hours post-SLT in the placebo and diclofenac study arms (mean = +4.05 ± 0.58 mm Hg and +4.47 ± 0.73, respectively, P < 0.001 vs. pre-SLT IOP), which was prevented by apraclonidine (mean = ?2.41 ± 0.88 mm Hg, P < 0.0001 vs. other study arms post-SLT). There were no significant differences between the 3 arms of the study on the long-term IOP reduction achieved by SLT (6 wk: P = 0.51, 6 mo: P = 0.42). Conclusions: Neither the use of apraclonidine before SLT nor diclofenac after SLT significantly influenced the IOP reduction induced by SLT. Except for a slight and transient reduction in intraocular inflammation, there was no beneficial effect of diclofenac on early IOP changes or the degree of patient discomfort relative to placebo.

    关键词: open-angle glaucoma,non–steroidal anti-inflammatory,selective laser trabeculoplasty,intraocular pressure,ocular hypertension

    更新于2025-09-23 15:21:01

  • Randomized Prospective Study of the Use of Anti-Inflammatory Drops After Selective Laser Trabeculoplasty

    摘要: Purpose: Evaluating the use of Indomethacin, Dexamethasone, and no anti-inflammatory treatment immediately after selective laser trabeculoplasty (SLT). Materials and Methods: Prospective randomized clinical trial of 132 eyes. Both eyes of the patient underwent SLT. One of the eyes was treated with Indomethacin 0.1% or Dexamethasone 0.1% 3 times daily for 1 week; the other eye did not receive any anti-inflammatory treatment. Intraocular pressure (IOP) and inflammatory parameters were recorded at 1 hour, 1 week, 1, 3, and 6 months. Results: Cells in the anterior chamber were present in 57% to 71% of the patients after 1 hour. About 16% to 37% of the patients reported pain/discomfort after 1 hour. Redness was present before SLT in 29% to 34% of the patients, probably due to antiglaucoma medication. After 1 hour, the amount of redness recorded raised to 32% to 42%, but the amount of patients with redness returned to pretreatment levels after 1 week. An IOP peak of >5 mm Hg above baseline IOP 1 hour after laser was present in 3% to 9% of the patients. IOP lowered 11% to 21% compared with IOP at baseline. The number of medications needed changed from 1.45 to 1.49 before, to 0.23 to 0.45 six months after SLT. No differential effects based on the kind of anti-inflammatory treatment or no treatment were found for any of the parameters. Conclusions: SLT induces little inflammation: anti-inflammatory drops do not make a significant difference in pain, redness, cells in anterior chamber, or peak IOP following SLT. The IOP-lowering effect of the SLT is not influenced by the use of Indomethacin or Dexamethasone.

    关键词: anti-inflammatory drops,use of steroids,selective laser trabeculoplasty,glaucoma,side effects of SLT

    更新于2025-09-23 15:21:01