Open-path Halon 1301 NDIR sensor with temperature compensation
摘要: Halon 1301 (bromotrifluoromethane) is a kind of fire extinguishing agent in aviation industry. Volume concentration measurement of Halon 1301 is necessary in the design of aircraft fire protection systems. In this research, an open-path Halon 1301 non-dispersive infrared (NDIR) sensor has been developed for in-situ measurement, a novel cavity-type absorption module was designed to get fast response and more compact structure. Experiment results show that measurement was remarkably affected by temperature. Therefore, temperature compensation algorithm was also studied in this thesis, which was proven to be effective within the range of 25 oC-105 oC.
关键词: non-dispersive infrared (NDIR),mid-infrared absorption spectrum,Halon 1301,temperature compensation,concentration measurement