- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Photocatalytic Studies of Tio2/Sio2 Nanocomposite Xerogels
摘要: The use of titania-silica materials in photocatalytic processes has been proposed as an alternative to the conventional TiO2 catalysts, in order to facilitate the separation of products after the reaction. However, despite the large number of research in this field, the mechanism governing the photocatalytic activity of the mixed TiO2/SiO2 oxides is not clear. Titania-Silica nanocomposite xerogels were prepared by sol-gel method. This work has been used to describe the synthesis and the photocatalytic properties of TiO2-SiO2 nanocomposite xerogel. The nanocomposite xerogels were prepared by keeping the molar ratio of TEOS:TTIP:MtOH:DIW at 1: 1:6:14 respectively and the catalysts used were HCl and NH4OH. After the preparation xerogels were characterized by FTIR, XRD, UV and LLS. All these techniques show the amorphous nature of Titania-silica xerogel.
关键词: UV,FTIR,Photocatalysis,TiO2-SiO2 mixed oxide,LLS,XRD
更新于2025-09-10 09:29:36
-
[IEEE 2018 34th International Conference on Lightning Protection (ICLP) - Rzeszow (2018.9.2-2018.9.7)] 2018 34th International Conference on Lightning Protection (ICLP) - Optical Lightning Measurement System and First Results
摘要: This paper introduces a newly developed optical lightning measurement system (OLMS). The OLMS is based on a video system using a camera with a 360° panorama view and a frame rate of 60 frames per second. The OLMS locates the lightning from the direction of the illuminated lightning channel and the travel time of the thunder sound. The analysis comprises 34 flashes containing 144 strokes, which occurred during the time period from 30th of July 2017 to 24th of August 2017. The results are compared to data obtained by the European lightning location network EUCLID. The comparison revealed a flash detection efficiency of 100 % and a stroke detection efficiency of 93.1 % for EUCLID. With EUCLID, the fraction of 92.5 % was classified correctly as cloud-to-ground lightning and the minor fraction of 7.5 % was miss-classified as cloud-to-cloud lightning. On average (arithmetic mean), the negative flashes contained 4.3 return strokes with 1.7 different striking points. For multi-stroke flashes with return strokes using the same lightning channel, EUCLID located the individual striking points with a median deviation of 57.3 m. The average striking distance was about 10 km. Due to the far distance the thunder sound could often not be separated from the thunder sound of other lightning. Therefore, the OLMS located the lightning with a relatively high deviation compared to the data of EUCLID. The arithmetic (geometric) mean value of the deviation was 1330 m (670 m).
关键词: optical measurement,detection efficiency,Lightning location system (LLS),multiple lightning flash,location accuracy,selectivity CG/CC
更新于2025-09-09 09:28:46