- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Water-sensitive ratiometric fluorescent probes and application to test strip for rapid and reversible detection of water
摘要: Naphthalimide-decorated fluorinated acetamides 1 and 2 were developed as solvent-sensitive dual emissive fluorescence probes. Particularly, 1 exhibited dual emission with a large Stokes shift for water, DMF, and DMSO solvents over other various organic solvents. The dual emission might be due to the increase of intramolecular charge transfer (ICT) of the naphthalimide moiety through the association of the difluorinated acetamide group with the solvent molecules. The 1 can give rise to a ratiometric change in the dual emission and a visual fluorescent color change depending on the water contents in organic solvents, including ethanol, methanol, acetonitrile and DMF solvents. Moreover, the 1-impregnated paper strips showed a rapid and easy-to-visualize fluorescent color change enabling water detection in organic solvents. These simple-to-use paper strips were also found to be reusable over 20 times.
关键词: Naphthalimide,Ratiometric fluorescence probe,Reusable test strip,Intramolecular charge transfer (ICT),Water detection
更新于2025-11-19 16:46:39
-
Copper nanoclusters @ nitrogen-doped carbon quantum dots-based ratiometric fluorescence probe for lead (II) ions detection in porphyra
摘要: A novel ratiometric fluorescence probe was proposed for detecting lead (II) ions (Pb2+) in porphyra, the approach was based on copper nanoclusters and nitrogen-doped carbon quantum dots (CuNCs-CNQDs). In this probe, the CuNCs delivered the response signal, the fluorescence of which was enhanced by Pb2+ due to the aggregation-induced emission enhancement (AIEE) between Pb2+ and CuNCs. The CNQDs provided the self-calibration signal, whose fluorescence remained almost unchanged in coexistence with Pb2+. According to the change of fluorescence intensity ratio between the fluorophores, CuNCs–CNQDs nanohybrid was used as ratiometric probes for the sensitive detection of Pb2+ in the range of 0.010 to 2.5 mg L-1, with a detection limit of 0.0031 mg L-1. Finally, the probe was successfully applied to detect Pb2+ in porphyra with relative standard deviations (RSDs) lower than 5%. This study provides a straightforward, stable, and sensitive approach for detecting Pb2+ in porphyra.
关键词: Lead (II) ions,Ratiometric fluorescence probe,Aggregation-induced emission enhancement,Copper nanoclusters,Nitrogen-doped carbon quantum dots
更新于2025-09-23 15:21:01