Evaluation of Light-Emitting Diodes’ Effects on the Expression Level of P53 and EGFR in the Gingival Tissues of Albino Rats
摘要: Background and objectives: The light-curing unit is considered an essential piece of equipment in every dental office. This study was conducted to evaluate the effect of Light-Emitting Diodes (LEDs) by the light cure (LC) device on gingival tissues of albino rats histologically and by regarding the expression of P53 and epidermal growth factor receptor (EGFR). Materials and methods: Gingival tissues of the rats were exposed to LEDs for 30 s with an interval of 30 s for periods of 2 and 5 min and were examined after two and four weeks of light exposure. After the set time, histological sections were studied and the P53 and EGFR expressions were evaluated immunohistochemically and by molecular methods. Results: Mild hyperplasia and mild inflammatory response were detected in higher rates after two weeks of exposure when compared to 4 weeks postexposure. Whereas fibrosis was found at a higher rate after four weeks than that found after two weeks postexposure, parakeratosis was seen only in the group that was exposed for 5 min to LC and when biopsies were taken after 2 weeks. We found that the immunohistochemical expression of P53 was not changed. Similarly, the alteration of EGFR expression was statistically nonsignificant (p > 0.05) when compared to the control group. The data obtained from the qRT-PCR reaction was analyzed using the comparative CT (2???CT) method. Statistically, there was no significant difference in the expression of EGER and P53 gene transcripts. Conclusions: LED causes no serious alteration in P53 and EGFR expression, and only trivial histopathological changes occurred, most of which recovered after a 4-week interval.
关键词: P53,qRT-PCR,EGFR,dental curing lights,blue light hazard
更新于2025-09-12 10:27:22
-
Comparison of the Amount of Temperature Rise in the Pulp Chamber of Teeth Treated With QTH, Second and Third Generation LED Light Curing Units: An In Vitro Study
摘要: Introduction: This in vitro study was designed to measure and compare the amount of temperature rise in the pulp chamber of the teeth exposed to different light curing units (LCU), which are being used for curing composite restorations. Methods: The study was performed in two settings; first, an in vitro and second was mimicking an in vivo situation. In the first setup of the study, three groups were formed according to the respective three light curing sources. i.e. quartz-tungsten-halogen (QTH) unit and two light-emitting diode (LED) units (second and third generations). In the in vitro setting, direct thermal emission from three light sources at 3 mm and 6 mm distances, was measured with a k-type thermocouple, and connected to a digital thermometer. For a simulation of an in vivo situation, 30 premolar teeth were used. Class I Occlusal cavity of all the teeth were prepared and they were restored with incremental curing of composite, after bonding agent application. While curing the bonding agent and composite in layers, the intrapulpal temperature rise was simultaneously measured with a k-type thermocouple. Results: The first setting of the study showed that the heat produced by irradiation with LCU was significantly less at 6 mm distance when compared to 3 mm distance. The second setting of the study showed that the rise of intrapulpal temperature was significantly less with third generation LED light cure units than with second generation LED and QTH light cure units. Conclusion: As the distance from the light source increases, less irradiation heat is produced. Third generation LED lights cause the least temperature change in the pulp chamber of single rooted teeth.
关键词: LED dental curing lights,temperature,QTH units,LED lights,pulp chambers,third generation LED lights,intrapulpal temperature rise
更新于2025-09-11 14:15:04