  • Ambient dose during intraoral radiography with current techniques: Part 1 conversion factor for scattered radiation using a rectangular collimator

    摘要: The aim of this study was to establish a conversion factor for assessing the scattered radiation produced during intraoral radiography with a rectangular collimator in areas where the remnant beam is not present. The dose level in the remnant beam will be addressed in another study. A radiological phantom (Rando) in the upright position was exposed to radiation delivered by a Planmeca Intra X-ray unit over 9 exposure geometries (right side of a full mouth series). For each geometry, the scattered radiation dose was measured at 5 locations in the horizontal plane and 4 locations in the vertical plane in front of the patient. The measurements were corrected for background and leakage radiation. An inventory of the distributions of the different geometries with respect to their share of the total workload was created in order to assign the correct weightings of the total ambient scattered radiation for the different geometries. The weightings were used to construct a scattered radiation pattern for a representative mix of exposures. The maximum value found in this pattern was used to arrive at a safe conversion factor. The scattered ambient radiation dose was evenly distributed over the horizontal plane. The scattered ambient radiation dose ranged from 20 to 65% lower in the vertical plane. The conversion factor established for scattered ambient radiation was 0.05 μSv per mAs at 1 meter. This factor is 3-fold lower than the conversion factors reported previously.

    关键词: radiation protection,dental radiography,radiation monitoring,Dental Equipment

    更新于2025-09-23 15:23:52

  • Ambient dose during intra-oral radiography with current techniques: Part 2 quantifying the remnant beam - an <i>in vivo</i> study

    摘要: Objectives: (1) To find a safe reference transmission factor for the remnant beam to be used when assessing the remnant beam during intra-oral radiography. (2) To identify factors such as exposure type, side (left or right), gender and age that might significantly affect transmission. Methods: Measurements were performed in the remnant beam during 323 intra-oral exposures of 43 patients. The exposure parameters were 60 kV and 7 mA. These measurements were compared with values in the same setting, but without a patient present to arrive at a transmission value. Differences between types of exposure [bitewing (BW), incisor and canine (IC) periapical, premolar and molar (PM) periapical], exposure side (left or right), gender and age were statistically analysed. The reference value was based on the exposure yielding the highest transmission value, to which a safety margin of two standard deviations (SDs) was added, and then rounding up. Results: The respective mean transmission values (SD) for BW, IC and PM exposures were as follows: 1.78% (1.15%), 0.639% (0.63%) and 2.60% (0.98%). The differences between PM and IC and between BW and IC were significant (p > 0.01). The differences between exposure side, gender and age were not significant. The reference transmission value, which was calculated from the highest mean transmission percentage for PM (2.60%) plus twice the SD (0.98%) and rounding up, was 5%. Conclusions: A transmission factor of 5% could be used to assess the remnant beam during intra-oral radiography. Anterior exposures led to significantly lower transmission values than posterior exposures.

    关键词: radiation protection,dental radiography,dental equipment,radiation monitoring

    更新于2025-09-23 15:23:52

  • Intensity output and effectiveness of light curing units in dental offices

    摘要: Background: The aims of the study were measuring the light intensity of light curing units used in Qazvin’s dental offices, determining the relationship between the clinical age of these units and their light intensity, and identifying the reasons for repairing them. Material and Methods: In this cross-sectional study, the output intensity of 95 light curing devices was evaluated using a radiometer. The average output intensity was divided up into four categories (less than 200, 200-299, 300-500, and more than 500 mW/cm2). In addition, a questionnaire was designed to obtain information mainly about the type, clinical age, and frequency of maintenance of the units and the reasons for fixing them. Data were analyzed using Kolmogorov-Smirnov, chi-squared, and t-tests (p < 0.05) on SPSS 24. Results: A total of 95 light curing units were examined, with 61 (64.2%) of them being of the LED type and 34 (35.8%) of the QTH type. While average light intensity in LED units was significantly higher than in QTH devices, the two device types were not significantly different regarding desirable light intensity (i.e., ≥ 300 mw/cm2). A negative correlation was observed between clinical age and light intensity. In addition, bulb replacement in QTH devices was over three times as much as in LED units. Also, repairing QTHs was more than twice as much frequent as fixing LEDs. The most common reason for repair was the breakage of the tip of the device. Conclusions: The light intensity of LED units is significantly higher than that of QTH devices, and the frequency of repairing in QTHs was significantly more than in LEDs. Furthermore, light intensity decreases with aging, and dentists should regularly monitor the conditions of light units.

    关键词: Light curing unit,dental equipment,radiometer,light intensity,dental offices