[IEEE 2019 IEEE 26th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA) - Hangzhou, China (2019.7.2-2019.7.5)] 2019 IEEE 26th International Symposium on Physical and Failure Analysis of Integrated Circuits (IPFA) - Characterization of 1122nm Laser for Laser Based Fault Isolation Applications
摘要: This paper presents one of the first studies of the harmonic impact of a significantly large photovoltaic (PV) solar farm of 20 MW in a utility distribution system. This solar farm is a constituent of the 80-MW PV solar farm in Sarnia, Ontario, which is so far the largest solar farm in Canada. The utility network is modeled in detail using the commercial grade PSCAD/EMTDC software, which is validated through load flow studies conducted by CYME software and correlated with SCADA measurements. The validated network model is used for network resonance study and harmonics impact analysis of the solar farms under different network conditions. The harmonics data instrumented for several months were provided by the transmission utility at the two solar farm units and at the main feeder substation. These data were utilized for extensive harmonic impact studies with widely different short-circuit levels and network resonance conditions. This paper presents the detailed procedure adopted for performing such harmonic impact studies. It is concluded that this large solar farm may not cause any substantial voltage distortion on the distribution network during steady-state operating conditions. However, recommendations are made for utilities to perform such studies to ensure the safe operation of critical loads.
关键词: network resonance,total harmonic distortion,solar energy,harmonics,Distribution systems,total demand distortion,photovoltaic (PV) solar system,frequency scan
更新于2025-09-23 15:19:57
-
[IEEE 2019 Workshop on Recent Advances in Photonics (WRAP) - Guwahati, India (2019.12.13-2019.12.14)] 2019 Workshop on Recent Advances in Photonics (WRAP) - Stand-off Femtosecond Laser Induced Breakdown Spectroscopy of Metals, Soil, Plastics and Classification Studies
摘要: This paper presents one of the first studies of the harmonic impact of a significantly large photovoltaic (PV) solar farm of 20 MW in a utility distribution system. This solar farm is a constituent of the 80-MW PV solar farm in Sarnia, Ontario, which is so far the largest solar farm in Canada. The utility network is modeled in detail using the commercial grade PSCAD/EMTDC software, which is validated through load flow studies conducted by CYME software and correlated with SCADA measurements. The validated network model is used for network resonance study and harmonics impact analysis of the solar farms under different network conditions. The harmonics data instrumented for several months were provided by the transmission utility at the two solar farm units and at the main feeder substation. These data were utilized for extensive harmonic impact studies with widely different short-circuit levels and network resonance conditions. This paper presents the detailed procedure adopted for performing such harmonic impact studies. It is concluded that this large solar farm may not cause any substantial voltage distortion on the distribution network during steady-state operating conditions. However, recommendations are made for utilities to perform such studies to ensure the safe operation of critical loads.
关键词: network resonance,total harmonic distortion,solar energy,harmonics,Distribution systems,total demand distortion,photovoltaic (PV) solar system,frequency scan
更新于2025-09-16 10:30:52
-
[IEEE 2019 8th International Conference on Modeling Simulation and Applied Optimization (ICMSAO) - Manama, Bahrain (2019.4.15-2019.4.17)] 2019 8th International Conference on Modeling Simulation and Applied Optimization (ICMSAO) - Harmonic analysis of high penetration level of Photovoltaic generation in distribution network and solution studies
摘要: The high penetration level of Photovoltaic (PV) generation in distribution network reduces carbon emissions but also becomes problematic in terms of network management. Harmonic distortion is the main factor studied in this paper and a typical three-bus distribution network is built in MATLAB/Simulink to understand the harmonics problem. Results show that current harmonics are more vulnerable to fluctuate compared to voltage harmonics. Based on existing harmonic standards, total demand distortion of current (TDDi) is evaluated to estimate maximum PV penetration level at Point of Common Coupling (PCC), and the maximum acceptable TDDi at each bus differs according to specific loading and short-circuit levels. Meanwhile, total harmonic distortion of current (THDi) at inverter outputs represents inverter performance. Instead of assessing at standard test conditions (STC), the impact of irradiance variations is studied. Low irradiance results in an increased THDi of the inverter whilst doesn’t explicitly affect TDDi at PCC. A simple and low-cost solution is proposed to dynamically vary the settings of inverter’s filter elements against irradiance, and harmonic distortion at low irradiance of the inverter is successfully mitigated.
关键词: power system,total demand distortion,total harmonic distortion,irradiance,PV penetration level
更新于2025-09-12 10:27:22