研究目的
Investigating the therapeutic effects of a specific herbal medicine on a particular disease.
研究成果
An in-depth analysis and summary of the results summarized, emphasizing interpretability and forward-looking nature. Based on the results, it further refines the core findings, significance of the research, and suggestions for future studies.
研究不足
The technical and application constraints of the experiments, as well as potential areas for optimization.
1:Experimental Design and Method Selection:
Includes the overall experimental design rationale, the theoretical models or algorithms employed, and detailed procedures of the experimental methods.
2:Sample Selection and Data Sources:
Specifies the samples or datasets used in the experiment, including selection criteria and data acquisition methods.
3:List of Experimental Equipment and Materials:
Enumerates the required instruments, devices, and materials, along with their specifications and intended uses.
4:Experimental Procedures and Operational Workflow:
Provides a step-by-step description of the experimental process, covering equipment setup, data collection techniques, and control of variables during the experiment.
5:Data Analysis Methods:
Explains the approach for analyzing experimental data, including statistical techniques and software tools utilized.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Bruker AM 400 spectrometer
AM 400
Bruker
1H NMR spectra were obtained
-
model 2400 source meter
2400
Keithley Instruments, Inc. USA
measuring the generated photocurrent
-
Waters LCT Premier XE spectrometer
LCT Premier XE
Waters
HRMS measurements were performed
-
Varian Cary 100 spectrophotometer
Cary 100
Varian
UV-Vis absorption spectra were recorded
-
Varian Cray Eclipse fluorescence spectrophotometer
Cray Eclipse
Varian
fluorescence spectra were recorded
-
Versastat II electrochemical workstation
Versastat II
Princeton Applied Research
The cyclic voltammograms of the dyes were obtained
-
AM 1.5 solar simulator
91160
Oriel
Photovoltaic measurements were performed
-
Newport Oriel PV reference cell
Oriel PV
Newport
The power of the simulated light was calibrated
-
Newport-74125 system
74125
Newport Instruments
Action spectra of the incident monochromatic photon-to-electron conversion efficiency (IPCE) for the solar cells were obtained
-
Si detector
71640
Newport
The intensity of monochromatic light was measured
-
Zahner IM6e Impedance Analyzer
IM6e
ZAHNER-Elektrik GmbH & CoKG, Kronach, Germany
The electrochemical impedance spectroscopy (EIS) measurements of all the DSSCs were performed
-
登录查看剩余9件设备及参数对照表
查看全部