研究目的
Investigating the photovoltaic performance of one-axis multiple-positions sun-tracked photovoltaic panels based on solar geometry and the dependence of photovoltaic conversion efficiency on the incident angle of solar rays on PV panels.
研究成果
The annual electricity generation from INSA sun-tracked PV system with the β of INSA yearly adjusted four times is highly close to that from similar 2-axis sun-tracked PV system. The AEG of MP-PV increases with the increase of daily AZA adjustment number, but such increase is not noticeable when M>5. Optimal θa values for maximizing AEG were identified for different configurations of MP-PV, showing that MP-PV can achieve AEG close to that of 2A-PV systems with simpler tracking techniques.
研究不足
The study is limited to M=3, 5, and 7 for the number of daily azimuth angle adjustments, indicating a practical limitation on the frequency of adjustments. The reduction in annual electricity generation due to deviation from the optimal θa is less than 0.1%, suggesting minimal impact but also a limitation in precision.