研究目的
Investigating the therapeutic effects of a self-assembled carrier-free nanosonosensitizer for photoacoustic imaging-guided synergistic chemo-sonodynamic cancer therapy.
研究成果
The constructed Ce6-PTX@IR783 nanomedicine demonstrated high synergistically chemo-sonodynamic therapeutic efficacy both in vitro and in vivo, with high biodegradability, biocompatibility, and biosafety. The study provides a new strategy for high-efficient utilization of hydrophobic drugs and a simplified all-in-one theranostic nanosystem for tumor diagnosis and treatment.
研究不足
The study focuses on a specific nanosonosensitizer and its application in a particular type of cancer (4T1 breast cancer). The long-term biosafety and potential side effects in humans are not fully explored. The scalability and reproducibility of the self-assembly procedure for large-scale production need further investigation.
1:Experimental Design and Method Selection:
The study utilized hydrophilic-hydrophobic self-assembly technology to assemble hydrophobic organic dye Ce6 and broad spectral anti-cancer agent Paclitaxel with hydrophilic organic dye IR783 to generate nanoscale sonosensitizer, Ce6-PTX@IR
2:Sample Selection and Data Sources:
7 4T1 breast cancer cells were used for in vitro experiments, and 4T1-tumor-bearing mice were used for in vivo experiments.
3:List of Experimental Equipment and Materials:
Ce6, IR783, PTX, DMSO, PBS, Taxol, and various instruments like TEM, SEM, DLS, HPLC, UV-vis-NIR spectrophotometer, ESR, CLSM, and PA imaging system.
4:Experimental Procedures and Operational Workflow:
Synthesis of Ce6-PTX@IR783 nanomedicine, characterization, in vitro drug-releasing assay, detection of 1O2 generation, cytotoxicity evaluation, in vitro and in vivo PA imaging, blood circulation, biodistribution, biosafety evaluation, and in vivo synergistic therapeutic effect.
5:Data Analysis Methods:
Data were analyzed using various instruments and software tools for imaging, spectroscopy, and statistical analysis.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
SEM
Magellan 400
FEI Co.
Scanning electron microscopy for imaging
-
DLS
Nano ZS90
Malvern Instrument Ltd.
Dynamic light scattering for measuring hydrodynamic diameter
-
HPLC
Agilent 1260 Infinity II
Agilent
High performance liquid chromatogram for quantitative determination
-
UV-vis-NIR spectrophotometer
UV-3600
Shimadzu
Spectrophotometer for absorbance measurement
-
ESR
EMX
Bruker
Electron spin resonance for detecting singlet oxygen
-
Ce6
Sigma-Aldrich
Sonosensitizer
-
IR783
Sigma-Aldrich
Hydrophilic cyanine dye for tumor-targeting and photoacoustic imaging
-
PTX
Sigma-Aldrich
Chemotherapeutic agent
-
DMSO
Sinopharm Chemical Reagent Co.
Solvent
-
PBS
Shanghai Runcheng BioTech Co., Ltd.
Buffer solution
-
Taxol
Zhongshan Hospital of Fudan University
Chemotherapeutic drug
-
TEM
JEM-2100F
Transmission electron microscopy for imaging
-
CLSM
Confocal laser scanning microscopy for imaging
-
PA imaging system
Vevo LAZR-X
Visual Sonics
Photoacoustic imaging system
-