研究目的
Investigating the effects of pyrazine derivatives and substituted positions on the photoelectric properties and electromemory performance of D–A–D series compounds.
研究成果
The study demonstrated that the acceptor DPP, with one more nitrogen atom than DPx, exhibited stronger electron-withdrawing ability, leading to a red-shift in the ICT absorption bands and fluorescent emission spectra. The compounds showed high thermal stability and the fabricated memory devices exhibited binary non-volatile flash memory behavior with good repeatability.
研究不足
The study focused on the effects of pyrazine derivatives and substituted positions on the photoelectric properties and electromemory performance, but did not explore the potential for further optimization of the compounds' performance in other applications.
1:Experimental Design and Method Selection:
The study involved the synthesis of four different D–A–D compounds using pyrazine derivatives quinoxaline and pyridopyrazine as acceptors and benzocarbazole as the donor. The compounds were characterized using density functional theory (DFT), UV-vis spectroscopy, fluorescent spectroscopy, and cyclic voltammetry.
2:Sample Selection and Data Sources:
The compounds were synthesized through one-step Suzuki coupling reactions.
3:List of Experimental Equipment and Materials:
Materials included 4,4-dimethoxy benzil, liquid bromine, sodium borohydride, and others. Equipment included Varian AMX 400 for NMR, Bruker Daltonics Flexanalysis for MALDI-TOF MS, and NETZSCH STA 499C TG-DSC for thermal stability.
4:Experimental Procedures and Operational Workflow:
The synthesis involved reduction, condensation, and Suzuki coupling reactions. The memory devices were fabricated by vapor-depositing the compounds on ITO glass and then depositing an Al top electrode.
5:Data Analysis Methods:
The optical and electrochemical properties were analyzed using UV-vis and fluorescent spectroscopy, cyclic voltammetry, and thermogravimetric analysis.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Varian AMX 400
Varian
Used for measuring 1H and 13C NMR spectra.
-
Bruker Daltonics Flexanalysis
Bruker
Used for MALDI-TOF MS measurements.
-
NETZSCH STA 499C TG-DSC
NETZSCH
Used for thermal stability measurements.
-
Varian Cary 5000
Varian
Used for collecting UV-vis data.
-
LS55 fluorescent photometer
Perkin Elmer
Used for measuring fluorescent spectra.
-
CHI 760C
CHI
Used for measuring the electrochemical properties of the compounds.
-
Hitachi S 4700 scanning electron microscope
Hitachi
Used for capturing SEM images.
-
MFP-3DTM
Used for atomic force microscopy (AFM) measurements.
-
Keithley 4200
Keithley
Used for testing the performance of memory devices.
-