研究目的
Investigating the use of bio-based alternatives for PMMA as host matrix for luminescent solar concentrators (LSCs).
研究成果
The bio-based polyesters demonstrated potential as renewable matrices for high-performance LSCs, with optical efficiencies comparable or superior to those of PMMA-based LSCs. The GTPn copolymer showed higher compatibility with fluorophores and better film homogeneity, leading to higher optical efficiencies.
研究不足
The study is limited to the synthesis and characterization of two types of bio-based polyesters and their application in LSCs. The performance comparison is made with PMMA-based LSCs, and the study does not explore other potential bio-based matrices or fluorophores.
1:Experimental Design and Method Selection:
Two types of renewable polyesters were synthesized via a two-step melt-polycondensation reaction with dibutyl tin oxide as catalyst.
2:Sample Selection and Data Sources:
The polymers were characterized by 1H NMR, GPC, UV/Vis-NIR, DSC, and TGA.
3:List of Experimental Equipment and Materials:
Materials included 1,3-propanediol, dimethyl terephthalate, dibutyltin(IV) oxide, diethyl 2,3:4,5-di-O-methylene-galactarate, isosorbide, PMMA, Lumogen Red F350, and TPETPAFN. Equipment included a Varian Mercury Plus NMR spectrometer, Mettler Toledo TGA/SDTA851, PerkinElmer DSC, Jasco PU-2089 Plus chromatograph, PerkinElmer Lambda 650 spectrometer, and Horiba Jobin–Yvon Fluorolog-3 spectrofluorometer.
4:Experimental Procedures and Operational Workflow:
Polymer synthesis, film preparation, and optical efficiency measurements were conducted.
5:Data Analysis Methods:
Spectroscopic characterization and optical efficiency determination were performed.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Jasco PU-2089 Plus chromatograph
PU-2089 Plus
Jasco
Used for gel permeation chromatography.
-
PerkinElmer Lambda 650 spectrometer
Lambda 650
PerkinElmer
Used for spectrophotometric measurements.
-
Horiba Jobin–Yvon Fluorolog-3 spectrofluorometer
Fluorolog-3
Horiba Jobin–Yvon
Used for fluorescence spectra measurements.
-
Lumogen Red F350
F350
BASF
Used as a fluorophore in the preparation of luminescent solar concentrators.
-
TPETPAFN
AIEgen Biotech Co., Limited
Used as an aggregation-induced emission fluorophore in the preparation of luminescent solar concentrators.
-
PMMA
Aldrich
Used as a reference host matrix in the preparation of luminescent solar concentrators.
-
Varian Mercury Plus
Mercury Plus
Varian
Used for recording 1H NMR spectra.
-
Mettler Toledo TGA/SDTA851
TGA/SDTA851
Mettler Toledo
Used for thermogravimetric analyses.
-
PerkinElmer DSC
PerkinElmer
Used for differential scanning calorimetry.
-
登录查看剩余7件设备及参数对照表