研究目的
To develop a rapid, quantitative, and ultrasensitive method for detecting diclofenac residues in water samples using a novel SERS-based immunochromatographic assay with AgMBA@SiO2-Ab as an immunoprobe.
研究成果
The developed SERS-ICA method is highly sensitive, specific, and rapid for diclofenac detection in water samples, with an LOD of 0.07 pg mL-1 and completion within 15 minutes. It shows good reproducibility, stability, and applicability to real samples, making it suitable for environmental monitoring and other fields.
研究不足
The assay is specific to diclofenac and may not detect other compounds without modification. It relies on specific antibodies and could be affected by matrix effects in complex samples. Optimization of silica shell thickness and MBA amount is critical for performance.
1:Experimental Design and Method Selection:
The study designed a SERS-based immunochromatographic assay (ICA) for competitive detection of diclofenac (DCF). It utilized Ag@SiO2 core-shell nanoparticles as SERS substrates for signal enhancement.
2:Sample Selection and Data Sources:
Water samples (tap water and surface water) were spiked with DCF standards for analysis.
3:List of Experimental Equipment and Materials:
Chemicals included diclofenac sodium, silver nitrate, mercaptobenzoic acid (MBA), monoclonal antibodies, etc. Apparatus included a UV-2300 spectrophotometer, Tecnai G220 TEM, and RamTracer-200-HS portable Raman analyzer.
4:Experimental Procedures and Operational Workflow:
Synthesis of Ag, Ag@SiO2, and AgMBA@SiO2 nanoparticles; preparation of immunoprobe (AgMBA@SiO2-Ab); fabrication of ICA strips; application of samples to strips; SERS signal measurement using a Raman analyzer with 785 nm laser.
5:Data Analysis Methods:
SERS intensities at 1074 cm-1 were measured, and data were analyzed for quantification using inhibition ratios and standard curves, with statistical methods like relative standard deviation (RSD) for reproducibility.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Transmission electron microscopy
Tecnai G220
FEI Company
Used for characterizing the morphology and size of nanoparticles.
-
Digital camera
Cannon IXUS 125 HS
Cannon Inc.
Used for taking digital photographs of ICA strips.
暂无现货
预约到货通知
-
UV-2300 spectrophotometer
UV-2300
Techcom
Used for measuring UV-visible absorption spectra of nanoparticles.
暂无现货
预约到货通知
-
Portable Raman Analyser
RamTracer-200-HS
Opto Trace Technologies, Inc.
Used for measuring SERS signals from immunoprobes on ICA strips.
暂无现货
预约到货通知
-
Deionized-RO water machine
Dura 12 F V
THE LAB Com
Used for producing deionized water for experiments.
暂无现货
预约到货通知
-
登录查看剩余3件设备及参数对照表