修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

8 条数据
?? 中文(中国)
  • Diode Array Near Infrared Spectrometer Calibrations for Composition Analysis of Single Plant Canola (Brassica napus) Seed

    摘要: A canola breeder needs an accurate, rapid, non-destructive method for analyzing seeds from a single plant to select the most promising samples for further breeding trials. Near Infrared Spectroscopy (NIRS) is widely used for quantitative analysis of oilseeds in a non-destructive manner. This research was aimed at developing NIRS calibration models for single plant canola seed using a diode array NIRS (950-1650 nm wavelength range), multivariate prediction models, and a mirrored sample cup. Eighteen different NIRS calibration models were developed using 100 samples for each constituent with different pre-processing techniques (mean center, derivatives, variates) and models (PLS, PCR). The relative performance of different calibration models for each constituent was compared using R2, SEP, and ratio performance deviation (RPD) values obtained from the validation set of 30 samples. NIRS models developed using the PLS regression algorithm for moisture content (R2 = 0.97, SEP = 0.32, RPD = 6.13) and oil content (R2 = 0.84, SEP = 0.61, RPD = 4.16) were successful. However, acceptable NIRS models were not obtained for fatty acid and glucosinolates content likely due to limited variability and low levels of the constituent and a narrow wavelength range of the DA-NIR instrument.

    关键词: Moisture content,Diode array,Fatty acid composition,Mirrored cup,DA-NIRS,Oil content,Oleic acid,Stearic acid,NIRS calibration model,Palmitic acid

    更新于2025-09-23 15:23:52

  • Application of Capillary Zone Electrophoresis Coupled with a Diode Array Detector (CZE-DAD) for Simultaneous Analysis of Ibuprofen and Phenylephrine

    摘要: Background: A validated method based on capillary zone electrophoresis coupled with a diode array detector (CZE-DAD) was investigated for analyzing binary mixture of ibuprofen (IBU) and phenylephrine (PHE) in their bulk and combined dosage form. Objective: This binary mixture is a challenging one as IBU is acidic and PHE is alkaline, which may affect their simultaneous analysis using CZE. The literature lacks any CZE report for IBU and PHE simultaneous analysis. Methods: Fused silica capillary (85 cm × 75 μm id) was used, and the electrolyte was a 50 mM borate buffer adjusted to pH 11 with 0.5 M NaOH. Results: The concentration ranges were 5–200 and 5–100 μg/mL for IBU and PHE, respectively, using CZE. High efficiency was achieved (N > 92990). Reasonable migration time (tm) was attained (tm< 8.5 min). Conclusions: Although the results obtained by the proposed CZE method and reported HPLC method were statistically comparable, the proposed method showed lower linearity ranges, higher efficiency, and a more reasonable run time. Highlights: CZE-DAD was used for the analysis of IBU and PHE in bulk and tablets, as no report was found for their determination using CZE. Binary mixture is challenging due to differences in chemical and physical properties. A detailed discussion of electrophoretic parameters optimization is included. Confirmation of peak purity was attained using DAD.

    关键词: Capillary zone electrophoresis,phenylephrine,diode array detector,simultaneous analysis,ibuprofen

    更新于2025-09-23 15:21:01

  • Reference Module in Chemistry, Molecular Sciences and Chemical Engineering || SPECTROPHOTOMETRY/Diode Array ☆

    摘要: Diode array spectrometry represents a particular approach for characterizing the result of the interaction between electromagnetic radiation and the sample, based on simultaneous measurement of light intensity over small spectral intervals having equal width. This is achieved through the following sequential stages, as schematically shown in Figs. 1 and 2D: a. interaction between the polychromatic beam and the sample; b. spatial dispersion of the transmitted (eventually reflected or emitted) radiation according to wavelength on multiple channels of equal widths, by means of a fixed optical element; c. imaging the dispersed radiation in a focal plane; and d. (quasi)simultaneous sampling of the dispersed radiation interval using photosensitive detectors, precisely positioned in the focal plane.

    关键词: photodiode principle,Diode array spectrometry,concave diffraction gratings,spectrophotometry,instrumentation

    更新于2025-09-23 15:21:01

  • 34.3: <i>Invited Paper:</i> Printing Pixel Circuits on Light Emitting Diode Array for AMLED Displays

    摘要: An active matrix light emitting display module integrated with carbon nanotubes control circuits was fully printed. The high performance of super pure single-chirality carbon nanotube TFT provides super bright and low power consumption technologies for indoor and outdoor augmented reality that are highly desirable for civil and military display applications.

    关键词: Aerosol Jet Printing,Active Matrix LED Display Module,Single Chirality Semiconducting Single-Walled Carbon Nanotubes,Thin Film Transistors,Light Emitting Diode Array

    更新于2025-09-16 10:30:52

  • Experimental study on cooling of high-power laser diode arrays using hybrid microchannel and slot jet array heat sink

    摘要: In this study, a hybrid microchannel and slot jet array heat sink is designed and fabricated to achieve a better thermal performance of the high-power laser diode arrays. A standard commercial laser bar with wavelength of 808 nm is packaged on the heat sink and experiments are performed to assess the cooling performance of the hybrid heat sink. In the experiments, the forward voltage method is used to measure the chip temperature and the structure function method is applied to obtain the thermal resistance of the heat sink. Using the deionized water as coolant, the heat sink deals with a heat flux of up to 506 W/cm2 and the thermal resistance of the heat sink is only 0.23 K/W when the flow rate is 0.8 L/min (The average jet velocity is 13.3 m/s). The optical power can be up to 135.5 W corresponding to the wall plug efficiency of 64.2%. Compared with the published solutions related to cooling similar laser chips, the thermal resistance reduces by over 15%, indicating that this hybrid heat sink is an interesting solution to improve the cooling of the high-power laser diode arrays.

    关键词: High-power laser diode array,Cooling,Forward voltage method,Thermal resistance,Optical power

    更新于2025-09-16 10:30:52

  • Quantitative Analysis of Twelve Active Components Combined With Chromatographic Fingerprint for Comprehensive Evaluation of Qinma Prescription by Ultra-Performance Liquid Chromatography Coupled With Diode Array Detection

    摘要: A combination method of ultra-performance liquid chromatography (UPLC) coupled with diode array detection has been developed for quality evaluation of Qinma prescription (QMP), based on chromatographic fingerprint technology with the similarity analysis (SA) and the quantitative analysis of 12 components by hierarchical cluster analysis (HCA). The established method has been validated by linearity, precision, repeatability, stability and recovery tests. The UPLC fingerprints with 17 common peaks of 5 QMP samples prepared by different extraction methods including water decoction extraction, water extraction-ethanol precipitation method, ethanol reflux extraction, ethanol extraction-water precipitation method and methanol ultrasonic extraction were obtained, and the SA results indicated that similarity index was greatly influenced by the large peak. The similarity index ranged from 0.816 to 0.999 basing on 17 peaks, which has been decreased to 0.683–0.999 basing on 16 peaks without the large peak of baicalin (BA). The results of simultaneous quantification of 12 components in these 5 QMP samples proved that BA, gallic acid (GA), wogonoside (WOG) and gentiopicroside (GEN) were the major ingredients in QMP with high contents >1.44 (mg/g), indicating that ethanol reflux was the most effective extraction method. Integrating fingerprint analysis, simultaneous determination and HCA, the established method is rapid, sensitive, accurate and readily applicable. All the results indicated that the combination method can control the quality of QMP and its related traditional Chinese medicinal compounds more comprehensively and scientifically.

    关键词: quantitative analysis,Qinma prescription,similarity analysis,diode array detection,UPLC,hierarchical cluster analysis,chromatographic fingerprint

    更新于2025-09-12 10:27:22

  • Anion exchange polymeric sorbent coupled to high‐performance liquid chromatography with <scp>UV</scp> diode array detection for the determination of ten <i>N</i> ‐nitrosamines in meat products: a validated approach

    摘要: Among mechanisms and molecules presumably involved in the carcinogenicity induced by meat consumption, the N-nitrosamines (N-NAs) are a class of compounds characteristic of processed meats. In this work, an analytical method for the determination of 10 N-Nitrosamines (N-Nitrosomorpholine, N-Nitriosomethyethylamine, N-Nitrosopyrrolidine, N-Nitrosodiethylamine, N-Nitrosopiperidine, N-Nitrosodipropylamine, N-Nitrosomethylaniline, N-Nitrosodibutylamine, N-Nitrosodiphenylamine, N-Nitrosodibenzylamine) in fresh meats and meat products was developed, optimized and validated. The method is based on optimized sample purification by solid phase extraction (anion exchange polymeric sorbent) and separation/detection by high performance liquid chromatography coupled to UV diode array detection. The validation procedure allowed to ascertaining good analytical performances in terms of sensitivity, selectivity towards interfering compounds, accuracy and robustness. The values obtained for precision (range: 4.3% - 14.4%) and recovery percentages (range: 80.8% - 95.1%) were compared to reference values indicated in the Decision No. 657/2002/EC, resulting as compliant. The measurement uncertainty (lower than 14.6%) was satisfactory for each N-NA as well.

    关键词: meat,food safety,solid phase extraction,validation,diode array detection,Nitrosamines,processed meats,HPLC,carcinogenic compounds,anion exchange sorbent

    更新于2025-09-11 14:15:04

  • [IEEE 2018 1st International Cognitive Cities Conference (IC3) - Okinawa, Japan (2018.8.7-2018.8.9)] 2018 1st International Cognitive Cities Conference (IC3) - A Novel Image Analysis of Light Emitting Diode Array Biostimulation Applied on Microcirculation

    摘要: A novel development platform of the specific microcirculation analysis was proposed in this study. This study was to observe the effect of the blood microcirculation with LED stimulation. The experiment involved the light emitting diode array (LEDA), the designed control board and the image processing algorithm on the platform. LEDA (six LEDs, wavelength 660 nm, operating frequency 8 - 15 Hz) was used to stimulate the palm of the subject, and then, the microcirculation images were analyzed by the image processing algorithm. The blood velocity on the ring finger was increased after LEDA stimulation, and it was approximately 1.7 times compared with and without the light stimulation. Thus, LEDA stimulation on the palm enhanced the microcirculation. Also, a specific platform of LEDA system with microcirculation measurement was developed in this study.

    关键词: image processing algorithm,microcirculation,light emitting diode array

    更新于2025-09-04 15:30:14