修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

104 条数据
?? 中文(中国)
  • Recent Advances and Applications of Near Infrared Spectroscopy for Honey Quality Assessment

    摘要: Currently, most of the technologies used to identify honey quality are inefficient and costly. There is a necessity to develop a more effective one for honey quality assessment. Near Infrared Spectroscopy (NIRS) has the potential to be such a technique for its unique characteristics. This study reviews recent advances and applications of NIR spectroscopy in honey authentication domain including constituents, adulteration, brand, botanical origin and geographical origin. It presents a comprehensive using of this technology, with advantages and limitations, in honey quality detection, which offers insights on selecting the most appropriate NIR spectroscopic method for samples presentation, spectral acquisition, spectral pretreatment and modeling. Future research is to be focused on increasing model robustness, developing overall NIR spectroscopic database and a NIR-based integrated technology system on honey quality assessment.

    关键词: honey,near infrared spectroscopy,Advances,detection,applications

    更新于2025-09-04 15:30:14

  • Quantitative Determination of Fluorine Content in Blends of Polylactide (PLA)–Talc Using Near Infrared Spectroscopy

    摘要: Near-infrared spectroscopy (NIRS) has been widely used for quantitative and/or qualitative determination of a wide range of matrices. The objective of this study was to develop a NIRS method for the quantitative determination of fluorine content in polylactide (PLA)-talc blends. A blending profile was obtained by mixing different amounts of PLA granules and talc powder. The calibration model was built correlating wet chemical data (alkali digestion method) and NIR spectra. Using FT (Fourier Transform)-NIR technique, a Partial Least Squares (PLS) regression model was set-up, in a concentration interval of 0 ppm of pure PLA to 800 ppm of pure talc. Fluorine content prediction (R2 cal = 0.9498; standard error of calibration, SEC = 34.77; standard error of cross-validation, SECV = 46.94) was then externally validated by means of a further 15 independent samples (R2 EX.V = 0.8955; root mean standard error of prediction, RMSEP = 61.08). A positive relationship between an inorganic component as fluorine and NIR signal has been evidenced, and used to obtain quantitative analytical information from the spectra.

    关键词: quantitative calibration,fluorine,PLA,polylactide,blends,talc,near infrared spectroscopy

    更新于2025-09-04 15:30:14

  • Correlation of Near Infrared Spectroscopy Measurements with the Surface Roughness of Wood

    摘要: The surface roughness of Chinese fir and Eucalyptus wood samples were measured using the stylus profile method in order to investigate the correlation between near infrared (NIR) spectroscopy and surface roughness. The results showed that the NIR spectra absorption showed differences among samples from different surface roughnesses, and the absorption decreased with the increase of the surface roughness. A strong relationship was found between the surface roughness parameters, i.e., the arithmetical mean deviation of the profile (Ra), the ten-point height of irregularities (Rz), and the maximum height of profile (Ry). Based on the NIR spectra of the Chinese fir wood samples and the mixed wood samples of the two wood species, and the correlation coefficients of these two types of wood samples in a calibration set were 0.77 to 0.83 and 0.67 to 0.74, respectively. A relatively poor correlation was found in the model based on the Eucalyptus samples; however, it was still significant. These results suggested that there was relative information about the surface roughness from the NIR spectra, which further illustrated that the surface roughness may influence the effect of models for wood properties built by NIR data.

    关键词: Near infrared spectroscopy,Correlation,Wood,Surface roughness

    更新于2025-09-04 15:30:14

  • The Efficacy of Near-Infrared Spectroscopy Monitoring in Carotid Endarterectomy: A Prospective, Single-Center, Observational Study

    摘要: There has been no gold standard for intraoperative monitoring in carotid endarterectomy (CEA) till now. The purpose of the current study was to investigate the value of near-infrared spectroscopy (NIRS) monitoring in CEA and explore the thresholds for intraoperative cerebral hypoperfusion. Eighty-four consecutive patients who underwent CEA surgery in Xuan Wu Hospital of Capital Medical University from August 2015 to June 2016 were enrolled in this study. All patients were intraoperatively monitored by transcranial Doppler ultrasonography (TCD) and NIRS. Regional oxygen saturation (rSO2) monitored by NIRS and blood flow velocity of the middle cerebral artery (V-MCA) monitored by TCD were continuously recorded. Correlation analysis was conducted for NIRS and TCD monitoring values. Intraoperative shunting was performed in five patients according to the TCD monitoring results and surgeon preference. During clamping of the carotid artery, the Pearson correlation index between rSO2 and V-MCA was 0.581 (P<0.001). A cut-off of 12.3% decrease of rSO2 was identified as the optimal threshold for intraoperative hypoperfusion indicated by TCD monitoring, when the sensitivity and specificity were 74.6% and 91.7%, respectively, with a 0.609 Kappa value. Physical examination immediately after operation showed no ischemic injury occurred, and no death and stroke occurred during the postoperative hospitalization. Our study demonstrated that NIRS could serve as a favorable monitoring tool during CEA. A 12.3% decrease of rSO2 could be adopted as a reliable threshold for intraoperative cerebral hypoperfusion.

    关键词: carotid endarterectomy,transcranial Doppler ultrasonography,hypoperfusion,near-infrared spectroscopy

    更新于2025-09-04 15:30:14