- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Cross-Sectional and Longitudinal Assessment of Retinal Sensitivity in Patients With Childhood-Onset Stargardt Disease
摘要: Purpose: We assess cross-sectional and longitudinal microperimetry and full-field static perimetry-derived retinal sensitivity with conventional and volumetric indices of retinal function in childhood-onset Stargardt disease (STGD1). Methods: Subjects with molecularly confirmed childhood-onset STGD1 underwent full-field static perimetry and/or microperimetry using custom designed grids. Mean sensitivity (MS) and total volume (VTOT) were computed for each microperimetry test. MS, VTOT, and central field volume (V30) were computed for each full-field static perimetry test. Subjects under 18 years old at baseline were classified as children and subjects 18 years or older as adults. Results: A total of 43 children (mean age at baseline, 13.0 years; range, 8–17) and 13 adults (mean age at baseline, 23.1 years; range, 18–32) were included in the analysis. For full-field static perimetry and microperimetry for both subgroups, intraclass correlation coefficient results for MS and volumetric indices were good to excellent, indicating strong test–retest reliability. Interocular symmetry in terms of baseline measurements and the annual rate of progression was observed. A greater rate of progression was observed in childhood. Conclusions: To our knowledge, this is the first prospective study of retinal sensitivity in a large cohort of molecularly confirmed subjects with childhood-onset STGD1 demonstrating that children with STGD1 can reliably undertake detailed functional testing. Moreover, using custom designed grids and subsequent topographic analysis, volumetric indices of retinal function provide a reliable measure of retinal sensitivity.
关键词: endpoints,Stargardt disease,retina,clinical trials,ABCA4,perimetry,visual field,STGD1,Retinal sensitivity
更新于2025-09-23 15:22:29
-
Optical coherence tomography parameters predictive of visual outcome after anti-VEGF therapy for retinal vein occlusion
摘要: Purpose: To determine the optical coherence tomography (OCT) parameters that are predictive of visual outcome after anti-VEGF therapy for a retinal vein occlusion (RVO). Methods: Fifty-seven eyes with macular edema (ME) secondary to a central or branch RVO treated with bevacizumab or ranibizumab were studied. Spectral-domain OCT and microperimetry were performed before, 1, 3, and 6 months after the treatment and at the final visit. Central retinal thickness (CRT), macular volume (MV), integrity of the external limiting membrane (ELM), ellipsoid zone (EZ), and foveal bulge (FB), and photoreceptor outer segment (PROS) length were determined. Results: The mean follow-up period was 17.8±11.5 months. In 46 of the 57 eyes, a resolution of the ME was achieved. The pretreatment CRT and MV, presence of intact ELM, EZ, and FB, and PROS length at the time of ME resolution were significantly correlated with the best-corrected visual acuity and retinal sensitivity at the final visit (P0.050). Multiple regression analyses showed that the pretreatment MV had the highest correlation with the posttreatment best-corrected visual acuity and retinal sensitivity (P0.050). Conclusion: The CRT, MV, ELM, EZ, FB, and PROS length are predictive factors for the visual outcome after anti-VEGF therapy for RVO.
关键词: spectral-domain optical coherence tomography,visual acuity,retinal sensitivity,anti-VEGF therapy,retinal vein occlusion
更新于2025-09-23 15:21:01
-
Microperimetry for Geographic Atrophy Secondary to Age-Related Macular Degeneration
摘要: Geographic atrophy (GA) is a progressive, advanced form of age-related macular degeneration leading to visual function impairment and irreversible vision loss. Standard clinical tests to evaluate visual function in patients with GA provide poor anatomic-functional correlation, while fundus imaging does not assess the visual function deficit. Microperimetry is a psychophysical visual function test that spatially maps retinal sensitivity and allows for correlation of anatomic features with visual function. In this review, we present an overview of mesopic microperimetry for GA, including: commercially available microperimetry devices, strategies to capture a mesopic microperimetry test, and strategies to assess and interpret microperimetry data in patients with GA. We demonstrate the importance of microperimetry data for assessing GA progression and for evaluating visual function loss through anatomic-functional correlations. Although valuable, current microperimetry tests require an extensive time commitment from patient and examiner, and the development of faster, more reproducible, and accessible methods is important to enable broader use of microperimetry in both clinical and research settings.
关键词: anatomic-functional correlation,visual function,geographic atrophy,microperimetry,age-related macular degeneration,retinal sensitivity
更新于2025-09-19 17:15:36
-
Clinical Correlation between Retinal Sensitivity and Foveal Thickness in Retinitis Pigmentosa Patients
摘要: Purpose: To investigate the relationship between retinal structure and retinal sensitivity comparing data obtained using spectral-domain optical coherence tomography (SD-OCT) and microperimetry in retinitis pigmentosa (RP) and healthy patients. Methods: A total of 49 patients (98 eyes) with RP were divided into 4 groups according to the OCT findings: group A, patients with no macular changes; group B, patients with cystoid macular edema (CME); group C, patients with vitreomacular traction (VMT); group D, patients with retinal thinning. As a control group, we enrolled 27 healthy subjects. All subjects underwent a complete ophthalmologic examination, including SD-OCT and microperimetry. For the statistical analysis, Pearson correlation test and linear regression analysis were used. A p value <0.05 was considered statistically significant. Results: We did not find any significant difference in best-corrected visual acuity (BCVA), foveal thickness, or retinal sensitivity between group A and the healthy subjects (p>0.05). In group B, linear regression of logMAR versus foveal thickness and retinal sensitivity versus foveal thickness gave r values of 0.931 and 0.786, respectively. In group C, r values were 0.786 and 0.842, respectively, while in group D they were 0.816 and 0.795. Conclusions: This article shows the first application of the new microperimeter MP3 in patients with RP, which has proven to be very sensitive in detecting functional abnormalities in all the patients. Future studies should investigate the relationships among photoreceptor cell loss, retinal sensitivity, and fixation in patients with RP.
关键词: MP3,Microperimetry,Retinitis pigmentosa,Optical coherence tomography,Retinal sensitivity,Foveal thickness
更新于2025-09-10 09:29:36
-
Assessment of Central Retinal Sensitivity Employing Two Types of Microperimetry Devices
摘要: Purpose: To compare the retinal sensitivity measurements obtained with two microperimeters, the Micro-Perimeter 1 (MP-1) and the Optos optical coherence tomography (OCT)/scanning laser ophthalmoscope (SLO) in subjects with and without maculopathies. Methods: Forty-five eyes with no known ocular disease and 47 eyes with maculopathies were examined using both microperimeters. A contrast-adjusted scale was applied to resolve the different stimuli and background luminance existing between the two devices. Results: There was a strong ceiling effect with the MP-1 in the healthy group, with 90.1% (1136 of 1260) test points clustered at 20 dB. The mean sensitivity for the corresponding points in the OCT/SLO was 25.8 6 1.9 dB. A floor effect was also observed with the OCT/SLO in the maculopathy group with 9.7% (128 of 1316) points clustered at 9-dB values. The corresponding mean sensitivity in the MP-1 was 1.7 6 3.9 dB. A regression equation between the two microperimeters was established in the common 10 to19 dB intervals as: OCT/SLO ? 15.6 t 0.564 3 MP-1 (cid:2) 0.009 3 MP-12 t k (k is an individual point constant; MP-1 coefficient P , 0.001; MP-12 coefficient P ? 0.006). Conclusion: The OCT/SLO and the MP-1 provide two different ranges of contrasts for microperimetry examination. Broadening the dynamic range may minimize the constraint of the ceiling and floor effect. There is a significant mathematical relationship in the common interval of the contrast scale. Translational Relevance: Applying a unified and broadened dynamic range in different types of microperimeters will help to generate consistent clinical reference for measurements.
关键词: comparison,retinal sensitivity,microperimetry
更新于2025-09-04 15:30:14