研究目的
To develop bimodal nanosystems consisting of hydrophilic quantum dots (QDs) directly conjugated to Gd(III)-DO3A monoamide chelates for combining the advantages of both MRI and fluorescence-based tools.
研究成果
The developed nanosystems combine bright fluorescence with high relaxivities, making them suitable for T1-weighted MRI and fluorescence imaging. They show negligible cytotoxicity and efficiently label cells, indicating potential for investigating biological processes.
研究不足
The study focuses on in vitro applications and preliminary cytotoxicity assessments. Further in vivo studies are needed to evaluate the nanosystems' performance in biological environments.
1:Experimental Design and Method Selection
The methodology involved the synthesis of CdTe QDs in an aqueous medium, functionalization with Gd(III)-DO3A monoamide chelates, and characterization through optical spectroscopy, relaxometric measurements, and fluorescence correlation spectroscopy (FCS).
2:Sample Selection and Data Sources
HeLa cells were used as a model for biological interaction studies. The QDs and bimodal nanosystems were characterized using various spectroscopic and microscopic techniques.
3:List of Experimental Equipment and Materials
UV-Vis 1800 spectrophotometer (Shimadzu), LS55 spectrofluorometer (PerkinElmer), Bruker Minispec mq60 and mq20 relaxometers, confocal microscope (LSM 780, Carl Zeiss Meditec AG), ICP-OES (Thermo Scientific – iCAP 6300).
4:Experimental Procedures and Operational Workflow
The synthesis of QDs, conjugation with Gd(III) chelates, purification, and characterization steps were detailed, including the use of coupling agents and ultrafiltration for purification.
5:Data Analysis Methods
Data analysis included the calculation of QD concentrations, hydrodynamic diameters from FCS, relaxivities from relaxometric measurements, and cell viability from resazurin assays.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Bruker Minispec mq60 relaxometer
mq60
Bruker
Used for relaxometric measurements to evaluate the relaxivity properties of the bimodal nanosystems.
暂无现货
预约到货通知
-
Bruker Minispec mq20 relaxometer
mq20
Bruker
Used for relaxometric measurements at different magnetic field strengths.
暂无现货
预约到货通知
-
Confocal microscope
LSM 780
Carl Zeiss Meditec AG
Used for fluorescence correlation spectroscopy (FCS) analysis and confocal fluorescence microscopy.
ZEISS LSM 990 Spectral Multiplex
立即获取同款设备 -
ICP-OES
iCAP 6300
Thermo Scientific
Used for determining the concentration of gadolinium ions in the nanosystems.
暂无现货
预约到货通知
-
UV-Vis 1800 spectrophotometer
1800
Shimadzu
Used for electronic absorption spectroscopy to characterize QDs and bimodal nanosystems.
暂无现货
预约到货通知
-
LS55 spectrofluorometer
LS55
PerkinElmer
Used for emission spectroscopy to characterize the fluorescence properties of QDs and bimodal nanosystems.
暂无现货
预约到货通知
-
登录查看剩余4件设备及参数对照表
查看全部