研究目的
To establish the size dependences of ZnxCd1-xS:Mn QDs optical characteristics in a gelatin matrix.
研究成果
The study demonstrated the possibility of optical properties tuning of ZnxCd1-xS:Mn QDs by changing the size and composition. The mechanisms of trap state PL were proposed, and the behavior of PL intensity was associated with the proposed emission mechanism. Doping with manganese introduced a new PL band, indicating effective excitation transfer to Mn centers.
研究不足
The technical and application constraints include the broad excitonic peak and its overlap with other peaks in absorbance spectrum, which may affect the accuracy of size distribution estimation for the smallest particles in ensemble.
1:Experimental Design and Method Selection:
Aqueous synthesis in gelatin was used to prepare ZnxCd1-xS:Mn QDs with varying sizes by changing synthesis conditions such as the amount of precursors and temperature.
2:Sample Selection and Data Sources:
Photographic inert gelatin was used as the polymer matrix. Manganese source (MnCl2?4H2O) was added to establish 10 mol. % impurity concentration in QDs solution.
3:List of Experimental Equipment and Materials:
DRON-3 diffractometer for XRD measurements, USB2000 spectrophotometer for UV-Vis absorption spectra, MDR-23 diffraction monochromator and R928P photomultiplier for PL measurements.
4:Experimental Procedures and Operational Workflow:
QDs sizes were varied by changing synthesis conditions, such as temperature and the amount of precursors. Gelatin matrix was partially removed for XRD measurements.
5:Data Analysis Methods:
Particle sizes were estimated using Scherrer formula, Kayanuma formula, DLF equation, and Pesika method. Optical characteristics were analyzed based on UV-Vis absorption and PL measurements.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
USB2000 spectrophotometer
USB2000
Ocean Optics
Used for collecting UV-Vis absorption spectra of investigated QDs.
-
R928P photomultiplier
R928P
Hamamatsu
Used for detecting photoluminescence in PL measurements.
暂无现货
预约到货通知
-
DRON-3 diffractometer
DRON-3
Burevestnik
Used for XRD measurements to investigate the crystal structure of ZnxCd1-xS QDs.
暂无现货
预约到货通知
-
MDR-23 diffraction monochromator
MDR-23
LOMO
Used for PL measurements in conjunction with a photomultiplier.
暂无现货
预约到货通知
-
HPL-H77GV1BT-V1 diode module
HPL-H77GV1BT-V1
HPL
Used as an excitation source for PL measurements.
暂无现货
预约到货通知
-
登录查看剩余3件设备及参数对照表