研究目的
To study the effect of N2 on the time evolution of gas temperature, rotational temperature and the vibrational temperatures of CO2 and CO in a pulsed glow discharge using in situ narrowband Quantum Cascade Laser (QCL) absorption spectroscopy.
研究成果
The study demonstrates the effectiveness of QCL absorption spectroscopy in measuring the time evolution of temperatures in a pulsed glow discharge. It highlights the significant impact of N2 admixtures on the vibrational temperatures of CO2 and CO, showing non-equilibrium conditions and the role of N2 as an energy reservoir for CO2 asymmetric stretch levels.
研究不足
The study is limited by the assumption of no coupling between rotational and vibrational levels, which becomes less accurate for higher vibrational levels. Additionally, the instrumental broadening and rapid passage effects may introduce uncertainties in the measurements.
The experimental setup involves three colinear QCLs scanning three regions between 2179.20 and 2253.51 cm?1 to measure absorption spectra of CO2 and CO transitions in a pulsed glow discharge. The plasma is operated with a 5-10 ms on-off cycle, a discharge current of 50 mA, and a pressure of around 6.7 mbar. A fitting routine is used to extract temperatures from the measured absorption spectra.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
DC-coupled detector
PDAVJ8
Thorlabs
Used to record the spectral tuning and intensity variations of the lasers.
-
Oscilloscope
Waverunner 610Zi
LeCroy
Used to record detector signals.
-
Pulse delay generator
DG535
Stanford Research Systems
Used to shift the plasma trigger with respect to the master clock from the QCL driver.
-
FTIR spectrometer
Vertex 80v
Bruker
Used to monitor the formation of products downstream.
-
Quantum Cascade Laser
TO3-L-53, TO3-L-54, TO3-L-55
Alpes Lasers
Used for scanning absorption spectra of CO2 and CO transitions.
-
Neutral density filter
NDIR03B, NDIR10B
Thorlabs
Used to attenuate the laser beam.
-
Beam splitter
BBAR-2500-14000 nm, 25.4x0.5 mm
Spectrogon
Used to redirect part of the laser beam for calibration.
-
Neoplas Q-MACS Basic MC multichannel controller
Used to drive three QCL laser heads.
-
Germanium etalon
3 inch-long
Used for wavelength calibration.
-
High voltage power amplifier
10/40A-HS
Trek
Used to amplify the pulse for the plasma.
-
Mass flow controller
F-201CV
Bronkhorst
Used to control the gas flow.
-
Dry Roots pump
ACP 15
Pfei?er
Used to maintain the pressure in the reactor.
-
Automatic valve
EVR 116
Pfei?er
Used to adjust the effective pumping speed.
-
Feedback controller
RVC 300
Pfei?er
Used to control the pressure.
-
Pressure gauge
CMR 263
Pfei?er
Used to measure the pressure.
-