研究目的
To propose and demonstrate a reliable method for measuring specific contact resistivity (ρC) for graphene-metal contacts, addressing the challenges in characterizing these junctions, especially with small contacts and varying interfacial resistances.
研究成果
The proposed contact end resistance method effectively measures specific contact resistivity for graphene-metal contacts, showing significant differences between 'wet' and 'dry' samples due to interfacial oxide and carbide formation. It is more reliable than TLM for small contacts and enables comprehensive characterization with a single contact pair, making it suitable for studying two-dimensional materials.
研究不足
The method assumes negligible metal resistance, which may not hold for all materials. Variability in sample preparation (e.g., adsorbed chemicals) could affect results. The use of thicker graphite flakes for AES and XPS might not fully represent monolayer graphene behavior.
1:Experimental Design and Method Selection:
The study uses a contact end resistance measurement method derived from TLM and CBKR, with simulations in LTspice to validate the approach. It involves electrical measurements and material characterization via AES and XPS.
2:Sample Selection and Data Sources:
Single-layer graphene flakes exfoliated from pyrolytic graphite are used. Two types of samples are prepared: 'wet' (exposed to DI water) and 'dry' (kept in vacuum and heated) to control interfacial layer formation.
3:List of Experimental Equipment and Materials:
Equipment includes an electron beam lithography system, thermal evaporation tool (Tectra Mini-Coater), reactive ion etching tool, lock-in amplifier (EG&G 7260 DSP), Auger electron spectrometer (PHI 700), and XPS spectrometer (ULVAC-PHI VersaProbe II). Materials include SiO2-coated Si wafers, graphene, chrome/gold for contacts, and aluminum.
4:Experimental Procedures and Operational Workflow:
Fabrication involves exfoliating graphene, defining contacts with e-beam lithography and evaporation, patterning channels with RIE, and depositing aluminum contacts under controlled conditions. Electrical measurements are performed at ambient conditions using the lock-in amplifier, and material analysis is done with AES and XPS.
5:Data Analysis Methods:
Data is analyzed using equations from the transmission line model to extract ρC, RSH, and RC. Simulations in LTspice help interpret current flow paths and errors.
独家科研数据包,助您复现前沿成果,加速创新突破