研究目的
To develop a non-destructive and reusable electrochemiluminescence (ECL) interface for the detection of cell-released dopamine (DA), addressing the need for methods that can handle fluctuating DA concentrations outside living cells.
研究成果
The Au-WS2 nanocomposites enhance ECL effectively, enabling a sensitive, selective, and reusable sensor for DA detection with a wide linear range and low detection limit. The sensor successfully monitors DA release from PC12 cells, showing potential for biological and medical applications in studying DA-related processes.
研究不足
The study may have limitations in terms of the specificity towards other neurotransmitters or biomolecules in complex biological samples, and the reusability is demonstrated up to six times, which might degrade with more uses. Optimization for real-time in vivo applications could be challenging.
1:Experimental Design and Method Selection:
The study employs a simple and green method for in situ growth of gold nanoparticles on WS2 nanosheets to create Au-WS2 nanocomposites, which enhance ECL. The ECL interface is designed for label-free and non-destructive detection of DA.
2:Sample Selection and Data Sources:
WS2 nanosheets are exfoliated from bulk WS2 powder using BSA and ethanol. PC12 cells are cultured and used as a source of DA release, stimulated by K+ and inhibited by nifidipine.
3:List of Experimental Equipment and Materials:
Equipment includes TEM (Hitachi H-7650), HRTEM (JEOL-2100 F), UV-vis spectrophotometer (Cary 60), ECL analyzer (MPI-A), and a three-electrode setup with gold working electrode, platinum auxiliary electrode, and Ag/AgCl reference electrode. Materials include WS2 powder, HAuCl4, BSA, ethanol, K2S2O8, DA, and other chemicals from specified suppliers.
4:Experimental Procedures and Operational Workflow:
WS2 nanosheets are prepared by sonication and centrifugation. Au-WS2 nanocomposites are synthesized by adding HAuCl4 to WS2 nanosheets. The ECL interface is fabricated by dropping Au-WS2 onto a gold electrode. ECL measurements are performed in PBS buffer with K2S2O8, using cyclic voltammetry from -2.0 to 0 V at 0.1 V/s. DA detection involves adding DA solutions of varying concentrations and measuring ECL intensity.
5:0 to 0 V at 1 V/s. DA detection involves adding DA solutions of varying concentrations and measuring ECL intensity. Data Analysis Methods:
5. Data Analysis Methods: ECL intensity is analyzed to establish a linear relationship with DA concentration. Selectivity is tested against interferents like UA, AA, L-cys, and Glu. Stability and reusability are assessed through multiple detection cycles.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Transmission Electron Microscope
H-7650
Hitachi
Used for taking TEM images of WS2 nanosheets and Au-WS2 nanocomposites.
暂无现货
预约到货通知
-
High-Resolution Transmission Electron Microscope
JEOL-2100 F
JEOL
Used for HRTEM images and EDS spectrum of Au-WS2 nanocomposites.
暂无现货
预约到货通知
-
UV-vis Spectrophotometer
Cary 60
Agilent
Used for obtaining UV-vis absorption spectra of WS2 nanosheets and Au-WS2 nanocomposites.
Cary 60 UV-Vis Spectrophotometer
立即获取同款设备 -
ECL Analyzer
MPI-A
Xi’An Remax Electronic Science & Technology Co. Ltd.
Used for ECL measurements in the detection of dopamine.
暂无现货
预约到货通知
-
Water Purification System
Not specified
Millipore SAS Corporation
Used to prepare ultrapure water for aqueous solutions.
暂无现货
预约到货通知
-
登录查看剩余3件设备及参数对照表
查看全部