- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Chlorogenic Acid Supplementation Improves Multifocal Electroretinography in Patients with Retinitis Pigmentosa
摘要: To evaluate the effect of chlorogenic acid supplementation in patients with retinitis pigmentosa, we evaluated objective change in visual function with multifocal electroretinography, along with visual acuity, visual field, standard electroretinography, and contrast sensitivity. Eighteen patients diagnosed with retinitis pigmentosa were enrolled in this prospective, non-comparative, single-arm study. Multifocal electroretinography, best-corrected visual acuity in Early Treatment Diabetic Retinopathy Study letters, total point score on visual field examination with Humphrey Field Analyzer II, electroretinography, and contrast sensitivity were measured and repeated after 3 months supplementation with chlorogenic acid. The amplitude of ring 5 was significantly higher on multifocal electroretinography after 3 months of chlorogenic acid supplementation (7.2 ± 9.5 vs 8.3 ± 10.8 nV/deg2, mean ± standard deviation, P = 0.022). There were no significant changes in the best-corrected visual acuity, total point score on Humphrey Field Analyzer, 30 Hz flicker amplitude on standard electroretinography, or contrast sensitivity. Chlorogenic acid may have a beneficial effect on the peripheral area at the margins of retinal degeneration, and should be considered as an anti-oxidant for the management of retinitis pigmentosa.
关键词: Retinitis Pigmentosa,Oxidative Stress,Chlorogenic Acid,Retinal Degeneration,Antioxidants
更新于2025-09-23 15:22:29
-
Validation of spectrophotometric determination of chlorogenic acid in fermentation broth and fruits
摘要: A fast and accurate ultraviolet-visible (UV-vis) spectrophotometric method was established to determine the presence of chlorogenic acid (CGA) according to potassium ferricyanide-Fe (III) detection system. The reaction temperature and pH level greatly influenced the CGA absorption spectrum. Maximum UV-vis absorption wavelength occurred at 790 nm under the optimum conditions (at 25 ℃ and pH 7.0). The results of UV-vis were further assessed by comparing the results with those of high-performance liquid chromatography (HPLC). The proposed method showed a wide linear sensing range of 10.0-800.0 μg mL-1 (R2 = 0.9996) and a high degree of precision (%R.S.D. < 1.50) and recovery (%R.S.D. > 3.39). Results of CGA and HPLC methods correlated well with each other. The proposed accurate, rapid, sensitive, low-cost, and high-throughput method was successfully used to quantify CGA in fermentation broth and fruits (Mango). Therefore, it may be applied for measuring CGA in biological samples.
关键词: Ultraviolet-visible spectrum,Chlorogenic acid,biological samples,high-throughput,HPLC
更新于2025-09-23 15:21:21