  • Green fluorescent carbon quantum dots functionalized with polyethyleneimine, and their application to aptamer-based determination of thrombin and ATP

    摘要: Brightly fluorescent carbon quantum dots coated with polyethylenimine (PEI-CDs) were prepared using malic acid and PEI as the precursors. The PEI-CDs have a high quantum yield (41%) and green emission (peaking at 502 nm under 430 nm excitation), both of which are not affected by high ionic strength. The PEI-CDs have a positive charge at physiological pH values and can electrostatically bind aptamers with their negative charge. This is shown for aptamers binding thrombin or ATP. Binding of aptamers results in quenching of fluorescence. If thrombin or ATP are introduced, the respective aptamer will bind them, and the complex is then released from the PEI-CDs. Fluorescence increases in proportion to the analyte concentration. Under optimized conditions, thrombin and ATP can be sensitively and selectively detected by fluorometry with lower detection limits of 1.2 and 13 nM, respectively. The assay was successfully applied to the determination of thrombin and of ATP in spiked serum samples.

    关键词: Aptamer sensor,Thrombin detection,Serum analysis,Green luminescent,PEI-CDs,Malic acid,Polyethylenimine,Fluorescence assay,ATP detection,Hydrothermal reaction

    更新于2025-09-19 17:13:59

  • Aluminum(III) triggered aggregation-induced emission of glutathione-capped copper nanoclusters as a fluorescent probe for creatinine

    摘要: Glutathione-capped copper nanoclusters (CuNCs) are presented that display aggregation-induced emission (AIE). This feature was exploited for selective and sensitive quantification of creatinine (CRN) which is an important diagnostic parameter. In the presence of Al3+ ions, such CuNCs rapidly aggregate, and this induces enhanced a red emission. The AIE nature of CuNCs was proven via TEM and fluorimetry. On addition of CRN, the coordination between CRN and Al3+ ions led to the quenching of fluorescence due to weakening the AIE. The best fluorescence intensity was measured at excitation/emission peaks of 360/585 nm. Quenched fluorescence intensity showed a linear dependence on the concentrations of CRN in the range of 2.5–34 μgL?1 with a detection limit of 0.63 μgL?1. The sensing mechanism of probe for CRN detection is discussed. The probe was applied to the determination of CRN in spiked human serum samples and gave satisfactory results.

    关键词: Nanosensor,Renal biomarker,Serum analysis,Fluorescent nanomaterials,Metal nanoclusters,Nanoprobe,Paired t-test,Fluorometry,Real sample analysis