- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Spatial Interpolation Enables Normative Data Comparison in Gaze-Contingent Microperimetry
摘要: PURPOSE. To demonstrate methods that enable visual field sensitivities to be compared with normative data without restriction to a fixed test pattern. METHODS. Healthy participants (n ? 60, age 19–50) undertook microperimetry (MAIA-2) using 237 spatially dense locations up to 138 eccentricity. Surfaces were fit to the mean, variance, and 5th percentile sensitivities. Goodness-of-fit was assessed by refitting the surfaces 1000 times to the dataset and comparing estimated and measured sensitivities at 50 randomly excluded locations. A leave-one-out method was used to compare individual data with the 5th percentile surface. We also considered cases with unknown fovea location by adding error sampled from the distribution of relative fovea–optic disc positions to the test locations and comparing shifted data to the fixed surface. RESULTS. Root mean square (RMS) difference between estimated and measured sensitivities were less than 0.5 dB and less than 1.0 dB for the mean and 5th percentile surfaces, respectively. Root mean square differences were greater for the variance surface, median 1.4 dB, range 0.8 to 2.7 dB. Across all participants 3.9% (interquartile range, 1.8–8.9%) of sensitivities fell beneath the 5th percentile surface, close to the expected 5%. Positional error added to the test grid altered the number of locations falling beneath the 5th percentile surface by less than 1.3% in 95% of participants. CONCLUSIONS. Spatial interpolation of normative data enables comparison of sensitivity measurements from varied visual field locations. Conventional indices and probability maps familiar from standard automated perimetry can be produced. These methods may enhance the clinical use of microperimetry, especially in cases of nonfoveal fixation.
关键词: fundus perimetry,microperimetry,normative database,AMD,gaze-contingent
更新于2025-09-23 15:23:52
-
Improving Visual Field Examination of the Macula Using Structural Information
摘要: Purpose: To investigate a novel approach for structure-function modeling in glaucoma to improve visual field testing in the macula. Methods: We acquired data from the macular region in 20 healthy eyes and 31 with central glaucomatous damage. Optical coherence tomography (OCT) scans were used to estimate the local macular ganglion cell density. Perimetry was performed with a fundus-tracking device using a 10-2 grid. OCT scans were matched to the retinal image from the fundus perimeter to accurately map the tested locations onto the structural damage. Binary responses from the subjects to all presented stimuli were used to calculate the structure-function model used to generate prior distributions for a ZEST (Zippy Estimation by Sequential Testing) Bayesian strategy. We used simulations based on structural and functional data acquired from an independent dataset of 20 glaucoma patients to compare the performance of this new strategy, structural macular ZEST (MacS-ZEST), with a standard ZEST. Results: Compared to the standard ZEST, MacS-ZEST reduced the number of presentations by 13% in reliable simulated subjects and 14% with higher rates (≥20%) of false positive or false negative errors. Reduction in mean absolute error was not present for reliable subjects but was gradually more important with unreliable responses (≥10% at 30% error rate). Conclusions: Binary responses can be modeled to incorporate detailed structural information from macular OCT into visual field testing, improving overall speed and accuracy in poor responders. Translational Relevance: Structural information can improve speed and reliability for macular testing in glaucoma practice.
关键词: glaucoma,ganglion cells,optical coherence tomography,perimetry,visual field
更新于2025-09-23 15:23:52
-
Effect of Stimulus Intensity and Visual Field Location on Rod- and Cone-Mediated Pupil Response to Focal Light Stimuli
摘要: PURPOSE. To assess the effect of stimulus intensity on rod- and cone-mediated pupil light reflex (PLR) to small stimuli presented at central and peripheral visual field (VF) locations. METHODS. The PLR to small (0.43°) chromatic stimuli was tested in the right eye of healthy subjects. Blue (485 ± 20 nm) and red (625 ± 15 nm) stimuli were presented at incremental light intensities (0.5–3.75 log cd/m2) at peripheral (21.21°) and central (4.24°) VF locations using a chromatic pupilloperimeter under mesopic or blue light adaptation conditions. The percentage of pupil contraction (PPC), maximal pupil contraction velocity (MCV), latency of MCV (LMCV) and the ratio of central to peripheral responses for PPC (QPPC value) were determined. RESULTS. Under mesopic light adaptation conditions, the mean PPC recorded in response to red stimuli was lower than blue stimuli in all VF locations and light intensities, and the QPPC values were higher in response to red compared with blue light stimuli across the light intensity range tested. With blue background light, the pupil responses for red and blue light stimuli were approximately the same in the peripheral VF. LMCV was nearly constant in all VF locations for blue and red stimuli, respectively. CONCLUSIONS. The chromatic pupilloperimeter enables the assessment of rod- and cone-contribution to the PLR in different VF locations. The optimal light intensities determined here for the assessment of focal activation of the two photoreceptor systems may be used for clinical evaluation of photoreceptor health.
关键词: rod,cone,perimetry,pupillary light reflex,chromatic pupilloperimetry
更新于2025-09-23 15:23:52
-
Differences in Static and Kinetic Perimetry Results are Eliminated in Retinal Disease when Psychophysical Procedures are Equated
摘要: Purpose: We tested the hypothesis that clinical statokinetic dissociation (SKD, defined as the difference in sensitivity to static and kinetic stimuli) at the scotoma border in retinal disease is due to individual criterion bias and that SKD can be eliminated by equating the psychophysical procedures for testing static and kinetic stimulus detection. Methods: Six subjects with glaucoma and six with retinitis pigmentosa (RP) were tested. Clinical procedures (standard automated perimetry [SAP] and manual kinetic perimetry [MKP]) were used to determine clinical SKD and the region of interest for laboratory-based testing. Two-way Method of Limits (MoL) was used to establish the isocontrast region at the scotoma border in glaucoma and RP subjects. Method of Constant Stimuli (MoCS) and a two-interval forced choice (2IFC) procedure then were used to present static or kinetic (inward or outward) stimuli at different eccentricities within the isocontrast region. The results were fitted with psychometric functions to determine threshold eccentricities. Results: Clinical SKD was found in glaucoma and RP subjects, with variable magnitude among subjects, but significantly exceeding expected typical measurement variability. The resultant psychometric functions when using MoCS and 2IFC showed equal sensitivity to static and kinetic targets, thus eliminating SKD. Conclusions: Clinical SKD found using clinical techniques is due to methodologic differences and criterion bias, and is eliminated by using an equated and more objective psychophysical task, similar to normal subjects. Translational relevance: Eliminating SKD using a psychophysical approach minimizing criterion bias suggests that it is not useful to distinguish between normal and diseased fields.
关键词: glaucoma,retinitis pigmentosa,standard automated perimetry,statokinetic dissociation,Goldmann perimetry
更新于2025-09-23 15:22:29
-
Cross-Sectional and Longitudinal Assessment of Retinal Sensitivity in Patients With Childhood-Onset Stargardt Disease
摘要: Purpose: We assess cross-sectional and longitudinal microperimetry and full-field static perimetry-derived retinal sensitivity with conventional and volumetric indices of retinal function in childhood-onset Stargardt disease (STGD1). Methods: Subjects with molecularly confirmed childhood-onset STGD1 underwent full-field static perimetry and/or microperimetry using custom designed grids. Mean sensitivity (MS) and total volume (VTOT) were computed for each microperimetry test. MS, VTOT, and central field volume (V30) were computed for each full-field static perimetry test. Subjects under 18 years old at baseline were classified as children and subjects 18 years or older as adults. Results: A total of 43 children (mean age at baseline, 13.0 years; range, 8–17) and 13 adults (mean age at baseline, 23.1 years; range, 18–32) were included in the analysis. For full-field static perimetry and microperimetry for both subgroups, intraclass correlation coefficient results for MS and volumetric indices were good to excellent, indicating strong test–retest reliability. Interocular symmetry in terms of baseline measurements and the annual rate of progression was observed. A greater rate of progression was observed in childhood. Conclusions: To our knowledge, this is the first prospective study of retinal sensitivity in a large cohort of molecularly confirmed subjects with childhood-onset STGD1 demonstrating that children with STGD1 can reliably undertake detailed functional testing. Moreover, using custom designed grids and subsequent topographic analysis, volumetric indices of retinal function provide a reliable measure of retinal sensitivity.
关键词: endpoints,Stargardt disease,retina,clinical trials,ABCA4,perimetry,visual field,STGD1,Retinal sensitivity
更新于2025-09-23 15:22:29
-
Disorganization of Retinal Inner Layers (DRIL) and Neuroretinal Dysfunction in Early Diabetic Retinopathy
摘要: To elucidate the relationship between disorganization of retinal inner layers (DRILs) and retinal function in diabetic patients without diabetic retinopathy (DR) and with nonproliferative DR, but without diabetic macular edema (DME). Fifty-seven participants with diabetes mellitus (DM) and 18 healthy controls underwent comprehensive ophthalmic examination, fundus photography, and spectral-domain optical coherence tomography. Scans of the fovea were evaluated for the presence of DRIL. Retinal function was evaluated using Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity, the quick contrast sensitivity function (qCSF) on the AST Sentio Platform, short-wavelength automated perimetry (SWAP), standard automated perimetry (SAP), and frequency doubling perimetry (FDP). ANOVA and Kruskal-Wallis were used to compare retinal function in subjects with and without DRIL. Tukey-Kramer test and Wilcoxon were used for post hoc analysis. DRIL was identi?ed in 9 of 57 diabetic subjects. DRIL subjects had higher body mass index and longer diabetes duration compared to diabetic subjects without DRIL (P ? 0.03 and P ? 0.009, respectively). Subjects with DRIL had reduced ETDRS visual acuity (P ? 0.003), contrast sensitivity function (P ? 0.0003), and SAP performance (PSD, P < 0.0001) compared to controls and diabetic subjects without DRIL. Structural analysis revealed inner retinal thinning, and some outer retinal thinning, associated with DRIL. Diabetic subjects with DRIL have reduced retinal function compared to those without DRIL, and defective retinal lamination may be an early cellular consequence of diabetes responsible for this in some patients. Following further longitudinal studies, DRIL may be a readily available and reliable structural biomarker for reduced retinal function in early diabetic neuroretinal disease.
关键词: perimetry,diabetic retinopathy,contrast sensitivity,DRIL,OCT
更新于2025-09-23 15:21:01
-
Steady-state pattern electroretinogram and frequency doubling technology in anisometropic amblyopia
摘要: Background: Steady-state pattern electroretinogram (PERG) and frequency doubling technology (FDT) perimetry can be used to selectively investigate the activity of the M-Y ganglion cells in adult anisometropic amblyopes. Methods: Fifteen normal subjects (mean 27.8±4.1 years) and 15 adults with anisometropic amblyopia (mean 28.7±5.9 years) were analyzed using steady-state PERG and FDT. Results: The amplitude of steady-state PERG was significantly different not only among the control group and both the amblyopic eye (P=0.0001) and the sound eye group (P=0.0001), but also between the latter two groups (P=0.006). The difference in FDT mean deviation was statistically significant not only between the control group and amblyopic eye group (P=0.0002), but also between the control group and the sound eye group (P=0.0009). The FDT pattern standard deviation was significantly higher in the control group rather than in the amblyopic eye (P=0.0001) or the sound eye group (P=0.0001). A correlation was found between the reduction in PERG amplitude and the increase in FDT-pattern standard deviation index not only in amblyopic (P=0.0025) and sound (P=0.0023) eyes, but also in the healthy control group (P=0.0001). Conclusion: These data demonstrate that in anisometropic amblyopia, there is an abnormal functionality of a subgroup of the magnocellular ganglion cells (M-Y), and the involvement of these cells, together with the parvocellular pathway, may play a key role in the clinical expression of the disease.
关键词: frequency doubling technology perimetry,pattern electroretinogram,amblyopia,retinogeniculate pathways
更新于2025-09-23 15:21:01
-
Enhanced Structure-Function Relationship in Glaucoma With an Anatomically and Geometrically Accurate Neuroretinal Rim Measurement
摘要: PURPOSE. To evaluate the structure–function relationship between disc margin–based rim area (DM-RA) obtained with confocal scanning laser tomography (CSLT), Bruch’s membrane opening–based horizontal rim width (BMO-HRW), minimum rim width (BMO-MRW), peripapillary retinal nerve fiber layer thickness (RNFLT) obtained with spectral-domain optical coherence tomography (SD-OCT), and visual field sensitivity. METHODS. We examined 151 glaucoma patients with CSLT, SD-OCT, and standard automated perimetry on the same day. Optic nerve head (ONH) and RNFL with SD-OCT were acquired relative to a fixed coordinate system (acquired image frame [AIF]) and to the eye-specific fovea-BMO center (FoBMO) axis. Visual field locations were mapped to ONH and RNFL sectors with fixed Garway-Heath (VFGH) and patient-specific (VFPS) maps customized for various biometric parameters. RESULTS. Globally and sectorally, the structure–function relationships between DM-RA and VFGH, BMO-HRWAIF and VFGH, and BMO-HRWFoBMO and VFPS were equally weak. The R2 for the relationship between DM-RA and VFGH ranged from 0.1% (inferonasal) to 11% (superotemporal) whereas that between BMO-HRWAIF and VFGH ranged from 0.1% (nasal) to 10% (superotemporal). Relatively stronger global and sectoral structure–function relationships with BMO-MRWAIF and with BMO-MRWFoBMO were obtained. The R2 between BMO-MRWAIF and VFGH ranged from 5% (nasal) to 30% (superotemporal), whereas that between BMO-MRWFoBMO and VFPS ranged from 5% (nasal) to 25% (inferotemporal). The structure–function relationship with RNFLT was not significantly different from that with BMO-MRW, regardless of image acquisition method. CONCLUSIONS. The structure–function relationship was enhanced with BMO-MRW compared with the other neuroretinal rim measurements, due mainly to its geometrically accurate properties.
关键词: glaucoma,structure–function relationship,visual field,optic nerve head,automated perimetry
更新于2025-09-23 15:21:01
-
Development of a Pediatric Visual Field Test
摘要: Purpose: We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. Methods: The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients’ experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4–16 years old) with no history of VF defects were recruited. Results: For the 14 subjects completing the study, 31 6 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 6 0.3 cd/m2 and 27.9 6 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher – 8.3 6 9.0 dB. Conclusions: Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Translational Relevance: Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population.
关键词: glaucoma,visual field,children’s vision,perimetry,psychophysics
更新于2025-09-23 15:21:01
-
Segmentation of the Optic Nerve Head Based on Deep Learning to Determine its Hemoglobin Content in Normal and Glaucomatous Subjects
摘要: Objective: To determine the limits of the optic nerve head (ONH) in color fundus images using Deep learning (DL) for the estimation of its hemoglobin topographic distribution. Also, to evaluate the usefulness of that distribution in glaucoma diagnosis singly or in association with perimetry. Methods: A DL method was trained using 40000 fundus images and applied to 89 normal eyes and 77 confirmed or suspect glaucomas. DL and manual segmentation were compared. The eyes were also examined once with TOP perimetry (Octopus 300) and Spectralis-OCT and twice with Cirrus-OCT and Laguna ONhE, a program which estimates hemoglobin from color photographs, using improved criteria from previous studies. Results: The Sorensen-Dice similarity index between manual and automatic segmentations was 0.993. Intra-class correlation coefficients were similar when comparing the results of the Laguna ONhE indices using the manual and automatic segmentations (confidence intervals: 0.933-0.978). For specificity close to 95%, the GDF index, a factor that measures the distribution of hemoglobin at the nerve, obtained sensitivities between 70.1 and 74.0% (manual vs. automatic segmentations). The retinal nerve fiber layer thickness (RNFLT) of both OCTs provided sensitivities between 67.1 and 68.8% and the BMO-RMW of Spectralis-OCT 69.7%. Associating several normalized indices, e.g. a new visual field harmony index (Threshold Coefficient of Variation, TCV) and GDF, provided 85.7% sensitivity for 97.8% specificity. GDF correlation with Spectralis-OCT BMO-RMW index was similar to that obtained between this index and the RNFLT of the same instrument. For 95% specificity, the diagnostic concordance (kappa value) between both Spectralis-OCT indices was 0.694 and between its BMO-RMW and Laguna ONhE GDF 0.804-0.828. Conclusion: A fully automatic delimitation of the optic nerve head allows the correct, reproducible and efficient use of the Laguna ONhE method, and its effectiveness is greatly increased if associated with a perimetric harmony index.
关键词: Glaucoma,Visual field,Hemoglobin,Perfusion,Morphology,Perimetry,Optic nerve head
更新于2025-09-19 17:15:36