研究目的
To develop a ratiometric fluorometric assay for the detection of silver(I) ions using a dually emitting quantum dot hybrid.
研究成果
The ratiometric fluorometric assay using N,Si-CQDs and NALC-CdTe QDs is highly selective and sensitive for Ag(I) detection, with potential applications in environmental monitoring. The fluorescence quenching mechanism involves the formation of AgTe and Ag-SR bonds on the QDs' surface.
研究不足
The method may have slight interference from Cu2+ ions, which can be mitigated with EDTA. Direct application in complex samples like wastewaters may require sample digestion to remove organic substances that absorb at the excitation wavelength.
1:Experimental Design and Method Selection:
The study employs a ratiometric fluorometric assay using a hybrid of blue-fluorescent silicon- and nitrogen-doped carbon quantum dots (CQDs) and red-emitting CdTe quantum dots (QDs) capped with N-acetyl-L-cysteine.
2:Sample Selection and Data Sources:
The assay was tested with surface water and wastewater samples.
3:List of Experimental Equipment and Materials:
Instruments included a Jem-1200 transmission electron microscope (TEM), AVATAR 370 FTIR spectrometer, SIRION-100 X-ray energy dispersive spectroscopy (EDS), F-2500 spectrofluorimeter, Cary 100 UV-Vis spectrophotometer, and MP 220 pH meter. Chemicals included N-acetyl-L-cysteine, 3-aminopropyl-triethoxysilane, sodium borohydride, tellurium powder, citric acid, cadmium chloride hydrate, silver nitrate, and others.
4:Experimental Procedures and Operational Workflow:
The N,Si-CQDs and NALC-CdTe QDs were synthesized and mixed to form a ratiometric fluorescent probe. The fluorescence intensity was measured at excitation and emission wavelengths of 350 nm and 441/608 nm, respectively.
5:Data Analysis Methods:
The relationship between the log of fluorescence intensity ratios and Ag(I) concentration was analyzed for linearity and detection limits.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
AVATAR 370 FTIR spectrometer
AVATAR 370
Thermo Nicolet
Recording Fourier transform infrared spectra (FTIR) in KBr
-
F-2500 spectrofluorimeter
F-2500
Hitachi
Recording fluorescence spectra
-
Cary 100 UV-Vis spectrophotometer
Cary 100
Agilent
Recording absorption spectra
-
Jem-1200 transmission electron microscope
Jem-1200
JEOL
Characterization of the size and surface morphology of QDs
-
SIRION-100 X-ray energy dispersive spectroscopy
SIRION-100
PEI
Elemental compositions and contents analysis of QDs
-
MP 220 pH meter
MP 220
Mettler Toledo
pH measurements
-