研究目的
This study investigated the immediate effect of LLLT pre-conditioning on BFR that accelerates muscle fatigue due to ischemia.
研究成果
LLLT pre-conditioning can minimize the BFR-related decline in muscle oxygen saturation, leading to force gradation and MU discharge in a cost-effective and complex manner.
研究不足
The study was limited to acute effects and did not investigate long-term adaptations. The sample size was small, and the study focused on a specific muscle group under controlled conditions.
1:Experimental Design and Method Selection:
A crossover randomized design was used to compare the effects of LLLT + BFR, BFR, and control conditions on muscle oxygen saturation, force fluctuation dynamics, and motor unit discharge patterns during low-load contractions.
2:Sample Selection and Data Sources:
Fifteen healthy right-handed adults participated. Muscle oxygen saturation was measured using near-infrared spectroscopy, and motor unit activity was recorded using multi-electrode surface EMG.
3:List of Experimental Equipment and Materials:
Equipment included a force transducer, multi-electrode surface EMG system, electric sphygmomanometer, pneumatic cuff, muscle oxygen sensor, and low-level laser therapy device.
4:Experimental Procedures and Operational Workflow:
Participants completed low-load contractions under three pre-conditioning protocols in a randomized order. Muscle oxygen saturation and motor unit activity were monitored during the contractions.
5:Data Analysis Methods:
Force fluctuation variables and motor unit discharge patterns were analyzed using statistical methods and signal processing techniques.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
force transducer
MB-100
Interface Inc.
Measure the force at the wrist joint
-
multi-electrode surface EMG
Bagnoli sEMG system
Delsys Inc.
Record the muscle activity of the extensor digitorum
-
electric sphygmomanometer
HEM-7121
OMRON Inc.
Determine systolic blood pressure
-
pneumatic cuff
Limited Edition, H+ Cuff
USA
Apply blood flow restriction to the muscle belly of the biceps brachii
-
muscle oxygen sensor
Moxy
Fortiori Design Inc.
Measure muscle oxygen saturation
-
low-level laser therapy
Laser 750
Electro-Medical Supplies Ltd.
Provide bio-energetic effect on the wrist extensor
-
登录查看剩余4件设备及参数对照表